49
EN
Appendix
Locking elements
Escape route
locking system
Operating voltage
Rated current
consumption
24 VDC
Locked signal
Door contact
Electric strike 331
with armature
and monitoring
contact
Versiondependent
24 VDC
160 mA
integrated
integrated
Electric strike 332
with armature
and monitoring
contact
Versiondependent
24 VDC
190 mA
integrated
integrated
Strike for swing
doors 351U66
Versiondependent
24 VDC
190 mA
integrated
external
Strike for swing
doors 351U80
with armature
and monitoring
contact
Versiondependent
24 VDC
190 mA
integrated
integrated
352M
with armature
and monitoring
contact
24 VDC
370 mA at operating
voltage –15 %
integrated
integrated
827H
24 VDC
300 mA
integrated
external
827
24 VDC
250 mA
Bridge 3 to 4
external
828
24 VDC
315 mA
integrated
external
DORMA TV50x
See Manufacturer’s specifications
integrated
integrated
GEZE SecuLogic
FTV 320
See Manufacturer’s specifications
integrated
integrated
Tab. 4 :
Locking elements and their voltage supply