User manual

TSB Controller 970-TSBC-30–10

Escape route technology

Summary of Contents for effeff 970-TSBC-30-10

Page 1: ...www assaabloy com de D0134300 User manual TSB Controller 970 TSBC 30 10 Escape route technology...

Page 2: ...herheitstechnik GmbH This document and all its parts are copyrighted Any use or changes outside the strict limits of the copyright are prohibited and liable to prosecution unless prior consent has bee...

Page 3: ...tion 9 Lines and wiring 10 Bus controller installation 11 Power supply 11 Connections 12 Resetting to factory settings 14 LED signalling 15 Set up operation 16 Check list 16 Turning on the system 16 N...

Page 4: ...fer Meaning of the symbols Danger Safety notice Failure to observe these warnings will lead to death or serious injury Warning Safety notice Failure to observe these warnings may lead to death or seri...

Page 5: ...ontroller and control devices when they are in a de energised state to eliminate any risk of physical injury or damage to the equipment Observe VDE regulations in this respect Danger due to faulty mai...

Page 6: ...B Controller and the individual escape door control units or control terminals peripherals takes place via the TS bus The TSB Controller must be mounted on top hat rails in accordance with DIN EN 6071...

Page 7: ...iguration and parametrisation for systems and devices Events logging Maintenance module As a central interface the FT Manager web interface offers the system integrator the option of integrating confi...

Page 8: ...l units or escape door control terminals and connected components such as escape door strikes and emergency open switches remain operative for safety reasons Control and monitoring Peripherals and esc...

Page 9: ...omply with safety regulations regarding work on electrical sys tems Important Components at risk of electrostatic discharge Electronic components in equipment should not be touched to ensure that elec...

Page 10: ...ls to the bus We recommend using telecommunications cable type J Y St Y with a cross section of 0 28 mm or 0 5 mm Do not use free wires in the bus line for additional control tasks or power supply to...

Page 11: ...in a protected area and not be exposed to direct sunlight When mounting the TSB Controlleron the wall take care not to damage any wiring or pipes inside the wall itself The module rack for the TSB Con...

Page 12: ...c no nc c no nc c no 2 11 12 14 13 ON 3 4 6 7 5 10 8 Functional earthing Connection Fire alarm No fire alarm Local connection Central connection Jumper 8 inserted Jumper 8 not inserted 10 9 8 7 Conne...

Page 13: ...18 Relay 2 no Relay 2 c Relay 2 nc 6 19 20 21 Relay 3 no Relay 3 c Relay 3 nc 7 22 23 24 Relay 4 no Relay 4 c Relay 4 nc 8 Jumper plug connector for deactivating a fire alarm system Jumper set Fire a...

Page 14: ...in the OFF position 2 Set DIP switch 2 from OFF to ON Red LED yellow LED and green LED flash 1 1 3 Wait at least 10 seconds Red LED continues to flash 1 1 yellow LED and green LED are off 4 Set DIP s...

Page 15: ...ooting takes about 20 seconds Only then will the controller take control of the LEDs Off On On Reference run bus scan Normal operation Off Off On Basic state no data traffic Off Flashes 5 1 Data traff...

Page 16: ...ipheral address Turning on the system Initial operation of peripheral devices 1 Switch on the power supply to each individual peripheral 2 Check each individual peripheral at its installation location...

Page 17: ...oordination with the network administrator required Configuration for use in the network Escape route technology network structure Fig 3 Network structure TS Bus Repeater 901 35 Service PC FT Manager...

Page 18: ...d and adjust if necessary to ensure that the TSB Controller can communicate with your PC The bus controller s DHCP server is active ex works 1 Open the Windows settings window Fig 4 1 2 Click Network...

Page 19: ...19 EN Set up operation Fig 4 Configuring the network connection 1 4 3 2 1 5 7 7 6...

Page 20: ...C This security certification is trustworthy but the web browser won t recognise it 3 You will therefore need to select Continue to load this website Fig 5 1 The FT Manager will now open in the browse...

Page 21: ...21 EN Set up operation Fig 5 Note on the safety certificate 1 Fig 6 Start interface of the FT Manager...

Page 22: ...years varies depending on the quality of the coin cell used Ethernet interface RJ45 Transmission rate 100 MBit s IEEE standard 802 3 100BASE TX TS bus interface 2 wire twisted pair cable Length of li...

Page 23: ...ews The latest information is available at www assaabloy com de Warranty The statutory warranty periods and ASSA ABLOY Sicherheitstechnik GmbH s Terms and Conditions of Sale and Delivery www assaabloy...

Page 24: ...kaging material to the distributor or trade professional for disposal free of charge at the place of handover Batteries The product contains disposable or rechargeable batteries Batteries must be remo...

Page 25: ...om removing the battery It is not necessary to remove the battery during normal use of the device Opening the housing can damage the device Only open the housing before disposing of the battery 1 Disc...

Page 26: ...400 m or to distributors of foodstuffs that offer electrical appliances several times a calendar year or continuously with a total sales area of 800 m In the case of online providers the total storage...

Page 27: ...27 EN...

Page 28: ...0 72458 Albstadt GERMANY Tel 49 7431 123 0 albstadt assaabloy com www assaabloy com de The ASSA ABLOY Group is the global leader in access solutions Every day we help people feel safe secure and exper...