80-9360-6007-152 04/18

DC6210 and DC6410 Series Closers

A14 Heavy Duty Friction Hold Open Parallel Arm

Installation Instructions

Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.  

All rights reserved. Reproduction in whole or in part without the express written 

permission of Corbin Russwin, Inc. is prohibited.

For installation assistance contact Corbin Russwin 

1-800-543-3658 • [email protected]

Figure 5 

4. Fasten Soffit Plate to Frame Soffit (under 

side of frame).

5. Connect Arm To Closer. (Figure 5)
 

Using hex wrench provided, close (turn 
clockwise) CLOSING SPEED VALVE (see 
page 5 for location on closer). 

DO NOT 

OVER TIGHTEN.

•  Open door to approximately 60°.
•  Using wrench on underside of spindle, 

rotate spindle approximately 135° toward 
hinge edge of door.

•  Install arm on spindle at an approximate 90° 

angle to door.

•  Reopen CLOSING SPEED VALVE.
•  Install and tighten arm washer and screw.

D

O

O

R

SPINDLE

ARM

CENTERLINE

ALL ANGLES SHOWN ARE APPROXIMATE

D

O

O

R

90°

SPINDLE
ROTATED 135°

Rotate 135°

SPINDLE AT REST

60°

DOOR

135°

WRENCH

90°

ARM

2

Installation

6. Adjust Hold Open Position. (Figure 6)

  Open door to desired degree of hold open. (If 

door does not open far enough, loosen Hold 
Open Adjustment Nut.) Place door at desired 
degree for hold open and tighten Hold Open 
Adjustment Nut.

 

Rotation:

 

Counter-clockwise will increase (+) angle.
Clockwise will decrease (-) angle.

 

NOTE: Pushing door beyond set hold 
open point may cause damage to product.

Friction Hold Open
Adjustment Nut

+

Figure 6 

Summary of Contents for DC6210 Series

Page 1: ...perty damage or personal injury and will void product warranty To avoid personal injury DO NOT DISASSEMBLE THIS DOOR CLOSER BODY Door closers must be securely fastened to a properly reinforced door an...

Page 2: ...HAND DOOR RHR LHR 1 Introduction L 3 8 10 1 4 20 THREAD Drill thru 9 32 7 1 Enlarge to 3 8 9 5 Dia This Side Only 4 Places DOOR THICKNESS SEX N LENGT 1 3 8 35mm 1 3 4 44mm OVER 1 9 32 1 21 32 MOUNTING...

Page 3: ...Opposite Dimensions given in inches mm Do Not Scale Drawing Closer must be installed in a true horizontal plane to ensure proper closer performance Friction Hold Open arms are handed and not reversibl...

Page 4: ...permission of Corbin Russwin Inc is prohibited For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com Pin Hole End Countersunk Holes Holding Pins 1 4...

Page 5: ...TIGHTEN Open door to approximately 60 Using wrench on underside of spindle rotate spindle approximately 135 toward hinge edge of door Install arm on spindle at an approximate 90 angle to door Reopen...

Page 6: ...pped elderly or small children may require even greater closing time Backcheck Location Valve Figure 8 Valve is closed as shipped from factory To increase degree of door opening where backcheck takes...

Page 7: ...tory set at an approximate Size 3 Full Cover Standard Slim Cover Option M76 Figure 10 Figure 11 Figure 12 4 Cover Installation Full Cover Standard Slim Cover Option M76 Install Cover Figure 11 Slip co...

Page 8: ...thout the express written permission of Corbin Russwin Inc is prohibited Patent pending and or patent www assaabloydss com patents Corbin Russwin 225 Episcopal Road Berlin CT 06037 Phone 800 543 3658...

Reviews: