background image

5

ED8200A Series

Installation Instructions

Fire-Rated Rim Exit Device

FM124B  04/20

For installation assistance contact Corbin Russwin 

1-800-543-3658 • [email protected]

Copyright © 2011, 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or 

in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

Installation

Mount ED8200A Exit Device

Installation of device depends on trim:

A.  For Reinforced Metal Doors:

• 

For throughbolted trim

 in 2-1/8

"

 prep, install device with two (2) fillister head screws (packed 

with trim) in latch assembly holes marked 

D

. (Figure 6) 

For all other applications

, install device with two (2) pan head machine screws and two (2) 

internal tooth lock washers in latch assembly holes marked 

C

.

•  Use level as shown to ensure device is level. Use rear bracket to spot, drill, and tap two (2) rear 

bracket mounting holes. Attach rear bracket to door using two (2) pan head machine screws and 

two (2) lock washers. Drill, tap, and install four (4) flat head machine screws in latch assembly 

holes marked 

E

. (Figure 6)

B.  For Un-Reinforced Doors Only:

•  Using device as a template, drill 1/4

"

 (6 mm) top and bottom latch assembly holes marked 

D

 

though door. Enlarge holes to 3/8

"

 (10 mm) from opposite side of door to clear for sex nuts. Install 

two (2) flat head machine screws and two (2) sex nuts. Drill and tap two (2) middle latch assembly 

holes marked 

E

 and install two (2) flat head machine screws (if applicable). (Figure 6)

C.  For All Other Door Types:

• 

For throughbolted trim

 in 2-1/8

"

 prep, install device with two (2) fillister head screws (packed 

with trim) in latch assembly holes marked 

D

. (Figure 6) 

For all other applications

, install device with two (2) pan head machine screws and two (2) 

internal tooth lock washers and two (2) sex nuts in latch assembly holes marked 

C

•  Use level as shown to ensure device is level. Use rear bracket to spot and drill 1/4

"

 (6 mm) holes 

through door. Enlarge holes to 3/8

"

 (10 mm) from opposite side of door to clear for sex nuts and 

bolts. Attach rear bracket to door using two (2) pan head machine screws, two (2) lock washers, 

and two (2) sex nuts. (Figure 6)

Figure 6 

 

Sex Nuts

Level

Rear 

Bracket

Lock 

Washer

Pan 

Head 

Machine 

Screw

Flat Head Machine Screw

Of Device

Stop Line

Latch 

Assembly

E

C

C

D

D

E

E

E

Sex Nuts

IMPORTANT

Maintain a 1/16" (2 mm) gap 

between stop and latch frame.

Summary of Contents for Corbin Russwin ED8200A Series

Page 1: ...of California to cause cancer and birth defects or other reproductive harm For more information go to www P65warnings ca gov Copyright 2011 2020 ASSA ABLOY Access and Egress Hardware Group Inc All rig...

Page 2: ...m designs are handed when used with this device see trim instructions Exit devices must be securely fastened to properly reinforced doors with fasteners which will not loosen or pull out Add reinforce...

Page 3: ...and 12 internal washers wood doors 12 x 1 1 4 Phillips pan head type A tapping screws Strike UL 4 12 24 x 7 8 Phillips flat head machine screws Front Bar Insert 1 8 32 x 1 Phillips pan head machine sc...

Page 4: ...part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited 3 Preparation cont c Cut Pushbar If Required Note If bar does not require cutting proceed t...

Page 5: ...assembly holes marked E Figure 6 B For Un Reinforced Doors Only Using device as a template drill 1 4 6 mm top and bottom latch assembly holes marked D though door Enlarge holes to 3 8 10 mm from oppo...

Page 6: ...e to fully project when door is closed Drill tap and install two 2 flat head machine screws in holes marked B Figure 7 Tighten all screws c Install Front Bar Insert Rear Front Covers A Slide front bar...

Page 7: ...yright 2011 2020 ASSA ABLOY Access and Egress Hardware Group Inc All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Gr...

Page 8: ...rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited For installation assistance contact Corbin Rus...

Reviews: