5
Surface Vertical Rod
Installation Instructions
Exit Devices
FM164 09/19
Copyright © 2013, 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
a
Change Hands
Remove four (4) screws and
vertical lifter assembly. Rotate
device to opposite hand (180˚).
Insert lifter assembly under
lift block and re-install screws.
Note
Lifter must fit under lift block as
shown. (Figure 4)
b
1/4-20 Sex Nut Option
Recommended for wood composite or unreinforced metal doors. (Figure 5)
Device
Quantity
Size
No trim
8
1/4 - 20
With trim
6
c
Rod Extension Options
• 2" (51 mm)
• 6" (152 mm)
• 12" (305 mm)
• 24" (610 mm)
• (Specify device finish)
Figure 4
Lift block
Vertical lifter
assembly
(4) 8-32 x 3/16" PRHMS
Vertical lifter
assembly
(4) 8-32 x 3/16" PRHMS
RHR Device
RHR Door
LHR Device
LHR Door
Figure 5
Note
Standard for Fire
Rated doors.
Figure 6