background image

6

80-9330-3003-152 04/18

DC3210 Series Closer

Installation Instructions

A11 or A12 Heavy Duty Spring Stop Parallel Arm

Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.  

All rights reserved. Reproduction in whole or in part without the express written 

permission of Corbin Russwin, Inc. is prohibited.

For installation assistance contact Corbin Russwin 

1-800-543-3658 • [email protected]

2

Installation

3. Mount Closer Body to Closer Bracket. 

(Figure 6) 

4. Fasten Arm Brackets to Frame

For Frame Templates “1A” and “1B” fasten 
main arm bracket to frame. Locate and install 
reinforced brackets 615F58 (1A) or 615F59 
Kit (1B).
For Frame Template “1C” fasten Flush 
Partition Bracket 615F60 to frame face 
and install main arm bracket to the 615F60 
Bracket.

5. Connect Arm To Closer (Figure 7)

Using hex wrench provided, close (turn 
clockwise) CLOSING SPEED VALVE. (Figure 
9) DO NOT OVER TIGHTEN.
• Open door to approximately 60°
• Using wrench on underside of spindle, 

rotate spindle approximately 135° toward 
hinge edge of door.

• Install arm on spindle at an approximate 90° 

angle to door.

• Reopen CLOSING SPEED VALVE.
• Install and tighten arm washer and screw.

Holding Pins

1/4-20 x 1/2 OHMS (2)

D

O

O

R

SPINDLE

ARM

CENTERLINE

ALL ANGLES SHOWN ARE APPROXIMATE

D

O

O

R

90°

SPINDLE
ROTATED 135°

Rotate 135°

SPINDLE AT REST

60°

DOOR

135°

WRENCH

90°

ARM

Figure 6 

Figure 7 

Summary of Contents for Corbin Russwin DC3210 Series

Page 1: ...or personal injury and will void product warranty To avoid personal injury DO NOT DISASSEMBLE THIS DOOR CLOSER BODY Door closers must be securely fastened to a properly reinforced door and frame with...

Page 2: ...615F59 CLAMP KIT FLUSH PARTITION APPLICATION WITH M104 OPTION 615F60 BRACKET A12 Hold Open Arm 1 Introduction L 3 8 10 1 4 20 THREAD Drill thru 9 32 7 1 Enlarge to 3 8 9 5 Dia This Side Only 4 Places...

Page 3: ...IM C DIM A DIM B DIM C DIM A DIM A DIM C 85 90 11 279 10 254 10 1 8 257 13 1 8 333 12 1 4 311 12 3 8 314 15 1 8 384 14 3 8 365 14 1 2 368 90 95 10 1 2 267 9 1 2 241 9 5 8 244 12 5 8 321 11 5 8 295 11...

Page 4: ...Application with 615F58 Bracket Figure 2 For Deep Reveal Frame Template 1B Figure 3 For Flush Partition Frame Template 1C Figure 4 1 2 12 7 2 3 4 70 FRAME STOP TOP OF DOOR C L HINGE OR PIVOT DOOR FRA...

Page 5: ...on 2 Install Closer Bracket Figure 5 1 2 12 7 C L HINGE OR PIVOT DOOR FRAME STOP 2 3 4 70 3 8 9 5 2 50 8 7 16 11 1 B TYP 1 3 8 35 REVEAL 5 16 8 2 1 8 54 4 3 8 69 9 615F59 CLAMP TYP Door Door Clamps wi...

Page 6: ...Locate and install reinforced brackets 615F58 1A or 615F59 Kit 1B For Frame Template 1C fasten Flush Partition Bracket 615F60 to frame face and install main arm bracket to the 615F60 Bracket 5 Connect...

Page 7: ...OSING and LATCHING speeds to between 3 and 7 seconds Use of door by handicapped elderly or small children may require even greater closing time Backcheck Intensity Valve Figure 9 Turn valve COUNTER CL...

Page 8: ...are factory set at an approximate Size 3 Full Cover Standard Slim Cover Option M76 Figure 12 Figure 13 Size of Door No of Full 360 Turns Clockwise of Power Adjuster Equivalent Closer Size Approx Inter...

Reviews: