19
Copyright © 2018 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
ED5000N Series Exit Devices For
9700 TCPIP1 & PWI1 Series Trim
2. Installation of Connectors
8) PIP (PoE) Wiring & Installation (Continued)
1. Tuck excess cable into wire hole on inside of door.
2. Secure the mounting assembly while ensuring proper
alignment of outside reader and fully tighten the (2) through-
bolts on the inside of the door to secure the reader and plate
to the door.
Secure the following connectors to their respective terminals (Fig. 9A):
A. Secure the 10-pin lock body assembly connector.
CAUTION - Do not touch or allow debris to enter connector contacts.
Secure Mounting Plate
B. Secure the 24-pin card reader connector (Fig. 9A).
C. Crimp* RJ45 to Cat 5e cable from hinge (Fig. 9B).
*For more detail, refer to section (5) ‘Installation Wiring’,
“A - Frame Harness Installation”.
TIA/EIA 568-B Standard Wiring
1 2
3 4
5 6
7 8
Do not confuse pair numbers with pin numbers. A pair number is
used for reference only (e.g.: 10BaseT Ethernet uses pairs 2 & 3). The
pin numbers indicate actual physical locations on the plug and jack.
PIN
Wire
Pair
Number
1
White/Orange
2
2
Orange
2
3
White/Green
3
4
Blue
1
5
White/Blue
1
6
Green
3
7
White/Brown
4
8
Brown
4
Fig. 9B
1
8
pin
8
1
pin
Crimp* to RJ45-M
Connector
Cat 5e
cable
from hinge
RJ45-M
C
Ground
Lugs
Lock
Body
(10-pin)
Reader
(24-pin)
Board-to-Board
Connector
Fig. 9A
B
A
IMPORTANT: Do not run wires through bottom hole in plate (Fig. 9A) - it will damage wires and
controller connector. Route wires around flange, do not route wires through the flange hole (Fig. 9A).
Summary of Contents for Corbin Russwin Access 700 ED5000N Series
Page 27: ......