Preparing for Installation
Function
The SE feature is available on all 3000/8000 series exit devices
and provides for latch retraction of the device from a remote
location. The exit device is Fail Secure—in the event of a power
failure, the exit device defaults to a latched condition. The linear
actuator is rated for both continuous and intermittent operation.
Specifications
Rated Voltage:
24 VDC
Rated Current:
0.4 Amperes (S) to retract; 0.2A to hold
(Nominal)
0.45A to retract; 0.25A to hold (Maximum)
Rated for continuous duty
Mounting Information
The exit device is mounted in the standard manner per the
specific exit device installation instructions. The exit device must
function mechanically prior to operating electrically.
CAUTION:
This product must be installed in accordance
with all applicable building and life safety
codes.
Safety Instructions
This device is limited in its applications, and should only interface
with components that are equally rated. Any failure to observe
and adhere to the operating limits may cause permanent
damage.
CAUTION:
Failure to ensure that there are no shorts
across power feed lines may result in damage
to power transfer and electric retraction of the
exit device.