background image

EP2C622D16-2T

User Manual

Version 1.0

Published May 2019

Copyright©2019 ASRock Rack INC. All rights reserved.

Summary of Contents for EP2C622D16-2T

Page 1: ...EP2C622D16 2T User Manual Version 1 0 Published May 2019 Copyright 2019 ASRock Rack INC All rights reserved...

Page 2: ...mplied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall ASRock Rack its directors officers employees or agents...

Page 3: ...ant to know more about ASRock Rack you re welcome to visit ASRock Rack s website at www ASRockRack com or you may contact your dealer for further information ASRock Rack Incorporation 6F No 37 Sec 2 J...

Page 4: ...nstallation Precautions 15 2 3 Installing the CPU and Heatsink 16 2 4 Installation of Memory Modules DIMM 19 2 5 Expansion Slots PCI Express Slots 22 2 6 Jumper Setup 23 2 7 Onboard Headers and Connec...

Page 5: ...nfiguration 57 3 3 6 USB Configuration 58 3 3 7 Super IO Configuration 59 3 3 8 Serial Port Console Redirection 60 3 3 9 H W Monitor 63 3 3 10 Runtime Error Logging 65 3 3 11 Intel SPS Configuration 6...

Page 6: ...Operating System 89 4 2 Support CD Information 89 4 2 1 Running The Support CD 89 4 2 2 Drivers Menu 89 4 2 3 Utilities Menu 89 4 2 4 Contact Information 89 Chapter 5 Troubleshooting 90 5 1 Troublesho...

Page 7: ...m Factor 12 0 in x 13 0 in 30 5 cm x 33 0 cm Quick Installation Guide 1 x SATA3 Cable 60cm 1 x MINISAS Cable 12G 60cm 1 x I O Shield 2 x Screws for M 2 Sockets If any items are missing or appear damag...

Page 8: ...MM R DIMM LR DIMM NVDIMM 64GB 32GB 16GB 8GB 4GB DIMM Frequency R DIMM LR DIMM NVDIMM 2666 2400 2133 MHz Expansion Slot PCIe x16 SLOT2 Gen3 x16 link CPU2 SLOT3 Gen3 x16 link CPU2 SLOT4 Gen3 x16 link CP...

Page 9: ...s Watch Dog NMI Graphics Controller ASPEED AST2500 VRAM 16MB Rear Panel I O VGA Port 1 x D Sub Serial port 1 x COM port USB 3 0 Port 4 LAN Port 2 1 x RJ45 Gigabit Ethernet LAN port LAN Ports with LED...

Page 10: ...Temperature Sensing System Temperature Sensing Fan CPU Rear Front Fan Tachometer CPU Quiet Fan Allow Chassis Fan Speed Auto Adjust by CPU Temperature CPU Rear Front Fan Multi Speed Control Voltage Vol...

Page 11: ...erature 10 C 35 C Non operation temperature 40 C 70 C This motherboard supports Wake from on Board LAN To use this function please make sure that the Wake on Magic Packet from power off state is enabl...

Page 12: ...ty you can press the F6 key during the POST or the F2 key to enter into the BIOS setup menu to access ASRock Rack Instant Flash Just launch this tool and save the new BIOS file to your USB flash drive...

Page 13: ...8 DDR4_B1 64 bit 2 pin module Blue 88 DDR4_A1 64 bit 2 pin module Blue 88 DDR4_A2 64 bit 288 pin module White LAN1 1 1 HDLED RESET PLED PWRBTN PANEL1 1 USB_1 PCIE2 PCIE4 PCIE6 PCIE3 BATTERY1 1 1 SSATA...

Page 14: ...LGA 3647 CPU Socket CPU2 15 1 x 288 pin DDR4 DIMM Slot DDR4_J2 White 16 3 x 288 pin DDR4 DIMM Slots DDR4_J1 DDR4_K1 DDR4_L1 Blue 17 SATA3 DOM Connector SSATA_4 Red 18 SATA3 DOM Connector SSATA_5 Red...

Page 15: ...m Management Bus header IPMB_1 40 System Panel Header PANEL1 41 M 2 Socket M2_2 Type 2230 2242 2260 2280 22110 42 CPU1 Fan Connector CPU1_FAN1 43 Rear Fan Connector REAR_FAN1 44 3 x 288 pin DDR4 DIMM...

Page 16: ...ue DDR4_J1 64 bit 288 pin module Blue DDR4_J2 64 bit 288 pin module White DDR4_D2 64 bit 2 pin module 88 White DDR4_D1 64 bit 2 pin module Blue 88 DDR4_E1 64 bit 2 pin module 88 Blue DDR4_F1 64 bit 28...

Page 17: ...1 Green STB PWR ready 2 FFAN_LED3 Red FRNT_FAN3 failed 3 CPU_FAN_LED2 Red CPU2_FAN1 failed 4 FFAN_LED1 Red FRNT_FAN1 failed 5 FFAN_LED2 Red FRNT_FAN2 failed 6 BMC_LED1 Green BMC heartbeat LED 7 RFAN_L...

Page 18: ...SB3_1_2 8 UID Switch UID LAN Port LED Indications There are two LED next to the LAN port Please refer to the table below for the LAN port LED indications Dedicated IPMI LAN Port LED Indications Activi...

Page 19: ...table below for the LAN port LED indications LAN LAN1 LAN2 Port LED Indications Activity Link LED Speed LED Status Description Status Description Off No Link Off 100Mbps connection or no link Blinking...

Page 20: ...lake EP Or successor CPU CPU 2 Purley Platform Skylake EP Or successor CPU CPU 2 PCH Lewisburg C622 PCH Lewisburg C622 RGMII SATA X4 DOM x2 PCIe 3 0 x16 Purley Platform Skylake EP Or successor CPU CPU...

Page 21: ...socket before touching any components 2 To avoid damaging the motherboard s components due to static electricity NEVER place your motherboard directly on the carpet or the like Also remember to use a...

Page 22: ...lease check if the PnP cap is on the socket if the CPU surface is unclean or if there are any bent pins in the socket Do not force to insert the CPU into the socket if above situation is found Otherwi...

Page 23: ...ou installed the heatsink you need to spray thermal interface material between the CPU and the heatsink to improve heat dissipation 2 Illustration in this documentation are examples only Heatsink or f...

Page 24: ...18 English 6 Tighten the two Middle Nuts to 12 IN LB Two turns at a time Tighten the two Corner Plunger to 12 IN LB Two turns at a time 6 1 6 2 6 3 6 4...

Page 25: ...module into a DDR4 slot otherwise this motherboard and DIMM may be damaged 2 For dual channel configuration you always need to install identical the same brand speed size and chip type DDR4 DIMM pair...

Page 26: ...20 English 1 2 3...

Page 27: ...is nearest to the CPU 1 CPU Configuration CPU1 A1 A2 B1 C1 D1 D2 E1 F1 1 DIMM 2 DIMMS 4 DIMMS 6 DIMMS 8 DIMMS 2 CPU Configuration CPU1 A1 A2 B1 C1 D1 D2 E1 F1 1 DIMM 2 DIMMS 4 DIMMS 8 DIMMS 16 DIMMS C...

Page 28: ...card Step 1 Before installing an expansion card please make sure that the power supply is switched off or the power cord is unplugged Please read the documentation of the expansion card and make nece...

Page 29: ...ecovery Jumper 3 pin ME_RECOVERY1 see p 7 No 34 Normal Mode Default ME Recovery Mode Chassis ID Jumpers Chassis ID0 Jumper 3 pin CHASSIS_ID0 see p 7 No 37 Chassis ID1 Jumper 3 pin CHASSIS_ID1 see p 7...

Page 30: ...0 see p 7 No 37 Chassis ID1 Jumper 3 pin CHASSIS_ID1 see p 7 No 36 Chassis ID2 Jumper 3 pin CHASSIS_ID2 see p 7 No 35 Reserved for system level use Reserved for system level use SATA DOM Power Jumpers...

Page 31: ...OM Power Jumper SATAPWR1 SATAPWR2 from pins 2 3 default to pins 1 2 If the connected SATA DOM does NOT require 5V power supply connect the SATA DOM power cable to the SATA DOM power header SATAPWR1 SA...

Page 32: ...restart PLED System Power LED Connect to the power status indicator on the chassis front panel The LED is on when the system is operating The LED is off when the system is in S4 sleep state or powered...

Page 33: ...n rates and power management equipment B Internet status indicator 2 pin LAN1_LED LAN2_LED These two 2 pin headers allow you to use the Gigabit internet indicator cable to connect to the LAN status in...

Page 34: ...ISAS_1 The connector supports MiniSAS to SATA data cables for internal storage devices with up to 6 0 Gb s data transfer rate USB 2 0 Connector USB_1 see p 7 No 29 USB 3 0 Header 19 pin USB3_5_6 see p...

Page 35: ...p 7 No 8 4 pin REAR_FAN1 see p 7 No 43 FAN1 SENSOR FAN_SPEED_CONTROL 12V FAN_VOLTAGE GND 6 5 4 3 2 1 FAN2 SENSOR NC FAN_SPEED FAN_SPEED_CONTROL FAN_VOLTAGE GND SENSOR NC 6 5 4 3 2 1 Please connect fa...

Page 36: ...itors the status of the power supply fan and system temperature Non Maskable Interrupt Button Header NMI_BTN1 see p 7 No 30 1 CONTROL GND Please connect a NMI device to this header Intelligent Platfor...

Page 37: ...U and NVME AHCI RAID on CPU PCIE With the introduction of the Intel VROC product there are three modes of operation SKU HW key required Key features Pass thru Not needed Pass thru only no RAID LED Man...

Page 38: ...s Code Description 0x10 PEI_CORE_STARTED 0x11 PEI_CAR_CPU_INIT 0x15 PEI_CAR_NB_INIT 0x19 PEI_CAR_SB_INIT 0x31 PEI_MEMORY_INSTALLED 0x32 PEI_CPU_INIT 0x33 PEI_CPU_CACHE_INIT 0x34 PEI_CPU_AP_INIT 0x35 P...

Page 39: ...71 DXE_SB_SMM_INIT 0x72 DXE_SB_DEVICES_INIT 0x78 DXE_ACPI_INIT 0x79 DXE_CSM_INIT 0x90 DXE_BDS_STARTED 0x91 DXE_BDS_CONNECT_DRIVERS 0x92 DXE_PCI_BUS_BEGIN 0x93 DXE_PCI_BUS_HPC_INIT 0x94 DXE_PCI_BUS_ENU...

Page 40: ...USB_ENABLE 0xA0 DXE_IDE_BEGIN 0xA1 DXE_IDE_RESET 0xA2 DXE_IDE_DETECT 0xA3 DXE_IDE_ENABLE 0xA4 DXE_SCSI_BEGIN 0xA5 DXE_SCSI_RESET 0xA6 DXE_SCSI_DETECT 0xA7 DXE_SCSI_ENABLE 0xA8 DXE_SETUP_VERIFYING_PASS...

Page 41: ...CY_OPROM_INIT 0xB3 DXE_RESET_SYSTEM 0xB4 DXE_USB_HOTPLUG 0xB5 DXE_PCI_BUS_HOTPLUG 0xB6 DXE_NVRAM_CLEANUP 0xB7 DXE_CONFIGURATION_RESET 0xF0 PEI_RECOVERY_AUTO 0xF1 PEI_RECOVERY_USER 0xF2 PEI_RECOVERY_ST...

Page 42: ...x57 PEI_CPU_MISMATCH 0x58 PEI_CPU_SELF_TEST_FAILED 0x59 PEI_CPU_NO_MICROCODE 0x5A PEI_CPU_ERROR 0x5B PEI_RESET_NOT_AVAILABLE 0xD0 DXE_CPU_ERROR 0xD1 DXE_NB_ERROR 0xD2 DXE_SB_ERROR 0xD3 DXE_ARCH_PROTOC...

Page 43: ...SWORD 0xD9 DXE_BOOT_OPTION_LOAD_ERROR 0xDA DXE_BOOT_OPTION_FAILED 0xDB DXE_FLASH_UPDATE_FAILED 0xDC DXE_RESET_NOT_AVAILABLE 0xE8 PEI_MEMORY_S3_RESUME_FAILED 0xE9 PEI_S3_RESUME_PPI_NOT_FOUND 0xEA PEI_S...

Page 44: ...ront rear UID blue LED indicator will be turned on Press the UID button again to turn off the indicator 2 10 Driver Installation Guide To install the drivers to your system please insert the support C...

Page 45: ...pter handles all non TCP IP traffic The Secondary adapter will receive fallback traffic if the primary fails If the Preferred Primary adapter fails but is later restored to an active status control is...

Page 46: ...SATA3 6 0 Gb s module and M 2 PCI Express module up to Gen3 x4 16 Gb s Installing the M 2_SSD NGFF Module Step 1 Prepare a M 2_SSD NGFF module and the screw 3 2 4 5 B C D E A 1 Step 2 Depending on th...

Page 47: ...5 if you are going to use the default nut Otherwise release the standoff by hand B C D E A Step 4 Peel off the yellow protective film on the nut to be used Hand tighten the standoff into the desired...

Page 48: ...42 English NUT1 NUT2 D E Step 6 Tighten the screw with a screwdriver to secure the module into place Please do not overtighten the screw as this might damage the module...

Page 49: ...a menu bar with the following selections Item Description Main To set up the system time date information Advanced To set up the advanced UEFI features IntelRCSetup For Intel CPU and chipset settings...

Page 50: ...selected items Tab Switch to next function Enter To bring up the selected screen PGUP Go to the previous page PGDN Go to the next page HOME Go to the top of the screen END Go to the bottom of the scr...

Page 51: ...glish 3 2 Main Screen Once you enter the UEFI SETUP UTILITY the Main screen will appear and display the system overview The Main screen provides system overview information and allows you to set the s...

Page 52: ...may set the configurations for the following items CPU Configuration DRAM Configuration Chipset Configuration Storage Configuration ACPI Configura tion USB Configuration Super IO Configuration Serial...

Page 53: ...o system stability or compatibility issues with some power supplies Please set this item to Disabled if above issues occur Intel Turbo Boost Technology Intel Turbo Boost Technology enables the process...

Page 54: ...ute Memory Protection Processors with No Execution Memory Protection Technology may prevent certain classes of malicious buffer overflow attacks Enable Intel TXT Support Enables Intel Trusted Executio...

Page 55: ...ed Halt State C1E for lower power consumption Hardware P States Disable Hardware chooses a P state based on OS Request Legacy P States Native Mode Hardware chooses a P state based on OS guidance Out o...

Page 56: ...quency automatically Numa Use this item to enable or disable Non Uniform Memory Access NUMA IMC Interleaving Select IMC Interleaving settings Channel Interleaving Select to configure Channel Interleav...

Page 57: ...disable Plus One Not supported when AEP dimm present Multi Rank Sparing Set Multi Rank Sparing number Default and the maximum is 2 ranks per channel Patrol Scrub Enable or disable Patrol Scrub Data Sc...

Page 58: ...only if the system supports 64 bit PCI decoding Primary Graphics Adapter If PCI Express graphics card is installed on the motherboard you may use this option to select PCI Express or Onboard VGA as th...

Page 59: ...nk Speed This allows you to select PCIE Link Speed PCIE2 ASPM Support This option enables or disables the ASPM support for all CPU downstream devices PCIE3 Link Width This allows you to select PCIE Li...

Page 60: ...the ASPM support for all CPU downstream devices SLIMELIN1 2 Link Speed This allows you to select PCIE Link Speed SLIMELIN1 2 ASPM Support This option enables or disables the ASPM support for all CPU d...

Page 61: ...isable SATA Controllers SATA M 2_SATA Mode Selection Identify the SATA port is connected to Solid State Drive or Hard Disk Drive Press Ctrl I to enter RAID ROM during UEFI POST process SATA ALPM Use t...

Page 62: ...56 English sSATA ALPM Use this item to enable or disable SALP...

Page 63: ...ble or disable PCIE devices to turn on the system from the power soft off mode Ring In Power On Use this item to enable or disable Ring In signals to turn on the system from the powersoftoff mode RTC...

Page 64: ...58 English 3 3 6 USB Configuration Legacy USB Support Use this option to enable or disable legacy support for USB devices The default value is Enabled...

Page 65: ...Serial Port Use this item to enable or disable the serial port Change Settings Use this item to select an optimal setting for Super IO device SOL Configuration Use this item to set SOL configuration...

Page 66: ...gs and specify how your computer and the host computer to which you are connected exchange information Both computers should hhave the same or compatible settings Terminal Type Use this item to select...

Page 67: ...he data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flow uses two wires to send start stop signals The options include None and Hardware RTS CTS VT UTF8 Com...

Page 68: ...erial port Terminal Type Use this item to select the preferred terminal emulation type for out of band management It is recommended to select VT UTF8 Option Description VT100 ASCII character set VT100...

Page 69: ...will controlled by BMC If Manual is selected configure the items below CPU1_FAN1 This allows you to set the CPU1 fan1 s speed The default value is Smart Fan CPU2_FAN1 This allows you to set the CPU2 f...

Page 70: ...rt fan s level speed Smart Fan Duty Control Smart Fan Duty x x means 1 to 11 stage This allows you to set duty cycle for each stage Smart Fan Temp Control Smart Fan Temp x x means 1 to 11 stage This a...

Page 71: ...features S W Error Injection Support When it is set to Enabled S W Error Injection is supported by unlocking MSR Ox790 Memory Error Memory enabling and logging setup option Correctable Error Threshold...

Page 72: ...66 English PCIE Uncorrected Error Enable Use this item to enable or disable PCIe Uncorrectable errors PCIE Fatal Error Enable Use this item to enable or disable PCIe Ftal errors...

Page 73: ...EP2C622D16 2T 67 English 3 3 11 Intel SPS Configuration ME Subsystem screen displays the Intel ME Subsystem Configuration information such as Operational Firmware Version and Firmware State...

Page 74: ...Use this item to enable or disable Intel R Volume Management Device Technology in this Stack When Enabled users are allowed to configure the options below VMD port 1A Use this item to enable or disab...

Page 75: ...ce Technology on specific root port VMD port 3C Use this item to enable or disable Intel R Volume Management Device Technology on specific root port VMD port 3D Use this item to enable or disable Inte...

Page 76: ...this Stack When Enabled users are allowed to configure the options below VMD port 2A Use this item to enable or disable Intel R Volume Management Device Technology on specific root port VMD port 2B U...

Page 77: ...se this item to enable or disable Intel R Volume Management Device Technology on specific root port VMD port 3C Use this item to enable or disable Intel R Volume Management Device Technology on specif...

Page 78: ...isk or hard drive and launch this tool then you can update your UEFI only in a few clicks without preparing an additional floppy diskette or other compli cated flash utility Please be noted that the U...

Page 79: ...as authority to change the settings in the UEFI Setup Utility Leave it blank and press enter to remove the password User Password Set or change the password for the user account Users are unable to ch...

Page 80: ...lt Secure Boot Keys Please install default secure boot keys if it s the first time you use secure boot Clear Secure Boot ke Force System to Setup Mode clear all Secure Boot Variables Change takes effe...

Page 81: ...CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test Key Exchange Keys Enroll Factory...

Page 82: ...ic Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default Exte...

Page 83: ...efaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 E...

Page 84: ...is option controls Legacy UEFI ROMs priority Boot From Onboard LAN Use this item to enable or disable the Boot From Onboard LAN feature Setup Prompt Timeout Configure the number of seconds to wait for...

Page 85: ...OEM Logo The default value is Enabled AddOn ROM Display Use this option to adjust AddOn ROM Display If you enable the option Full Screen Logo but you want to see the AddOn ROM information when the sy...

Page 86: ...ct Legacy only to run those that support legacy option ROM only Select Do not launch to not execute both legacy and UEFI option ROM Launch Video OpROM Policy Select UEFI only to run those that support...

Page 87: ...isabled with NVMe device but it is Legacy with other devices This item can t select Video Option ROM policy SLIMLIN1 1 Slot OpROM Use this item to select slot storage and Network Option ROM policy In...

Page 88: ...t Logging during system boot Erase Event Log The options include No Yes Next reset and Yes Every reset If Yes is selected all logged events will be erased When Log is Full Use this item to choose opti...

Page 89: ...EP2C622D16 2T 83 English All values changed here do not take effect until computer is restarted...

Page 90: ...specified time out BMC starts at the same time when BIOS starts during AC power ON It takes around 90 seconds to initialize Host to BMC interfaces Inventory Support This will execute inventory functio...

Page 91: ...l features of System Event Logging during boot Erase SEL Use this to choose options for earsing SEL When SEL is Full Use this to choose options for reactions to a full SEL Log EFI Status Codes Use thi...

Page 92: ...you prefer using a static IP address toggle to Yes and the changes take effect after the system reboots The default value is No Configuration Address Source Select to configure BMC network parameters...

Page 93: ...s on how to set up remote control environment and use the IPMI man agement platform please refer to the IPMI Configuration User Guide or go to the Support website at http www asrockrack com support ip...

Page 94: ...es and Exit When you select this option the following message Discard changes and exit setup will pop out Press ESC key or select Yes to exit the UEFI SETUP UTILITY without saving any changes Discard...

Page 95: ...necessary drivers and useful utilities that enhance the motherboard s features 4 2 1 Running The Support CD To begin using the support CD insert the CD into your CD ROM drive The CD automatically dis...

Page 96: ...settings 3 Check the settings of the 115V 230V switch on the power supply 4 Verify if the battery on the motherboard provides 3VDC Install a new battery if it does not If there is no video 1 Try replu...

Page 97: ...if the battery on the motherboard provides 3VDC Install a new battery if it does not 2 Confirm whether your power supply provides adaquate and stable power Other problems 1 Try searching keywords rela...

Page 98: ...f your invoice marked with the date of purchase is required By calling your vendor or going to our RMA website http event asrockrack com tsd asp you may obtain a Returned Merchandise Authorization RMA...

Reviews: