Serial Port for Out-of-Band Management/Windows Emergency
Management Services (EMS)
Out-of-Band Mgmt Port
Microsoft Windows Emergency Management Services (EMS) allows for remote
management of a Windows Server OS through a serial port.
Terminal Type
Use this item to select the preferred terminal emulation type for out-of-band management.
It is recommended to select [VT-UTF8].
Option
Description
VT100
ASCII character set
VT100+
Extended VT100 that supports color and function keys
VT-UTF8
UTF8 encoding is used to map Unicode chars onto 1 or more bytes
ANSI
Extended ASCII character set
Bits Per Second
Use this item to select the serial port transmission speed. The speed used in the host
computer and the client computer must be the same. Long or noisy lines may require lower
transmission speed. The options include [9600], [19200], [57600] and [115200].
Flow Control
Use this item to set the flow control to prevent data loss from buffer overflow. When
sending data, if the receiving buffers are full, a "stop" signal can be sent to stop the data
flow. Once the buffers are empty, a "start" signal can be sent to restart the flow. Hardware
flow uses two wires to send start/stop signals. The options include [None], [Hardware RTS/
CTS], and [Software Xon/Xoff].
Data Bits
Parity
Stop Bits