1.4  Motherboard Layout

DDR4_B1 (

64 bit, 288-pin module, Blue)

DDR4,

DDR4_B2 (

64 bit, 288-pin module, Blue)

DDR4,

24.4cm (9.6 in)

2

4

.4

c

(9

.6

in

)

ATXPWR1

DDR4_A1 (

64 bit, 288-pin module, Blue)

DDR4,

DDR4_A2 DDR4,

Blue

(

64 bit, 288-pin module,

)

1

PSU_SMB1

SYSTEM_FAN5

PCIE4

USB 3.0
T: USB2
B: USB1

IPMI
LAN

UID1

CLRMOS1

CPU_FAN1

SATA_0_7

COM2

1

BMC

AST2500

CPU1

BIOS
ROM

D2143D8UM / D2163D8UM

RoHS

DDR4_C2 (

64 bit, 288-pin module, Blue)

DDR4,

DDR4_C1 (

64 bit, 288-pin module,

)

DDR4,

Blue

DDR4_D2 (

64 bit, 288-pin module, Blue)

DDR4,

DDR4_D1 DDR4,

Blue

(

64 bit, 288-pin module,

)

CO

M

1

V

G

A

1

PCIE6

MEZZ_MB_A1

MEZZ_MB_C1

MEZZ_MB_B1

M2_30

M2_42

M2_60

M2_80

M

2

_

1

Dr.

Debug

BAT1

1

AEP_2

SSATA_0

SSATA_2

SSATA_1

SSATA_3

SYSTEM_FAN4

1

SATAPWR2

PANEL1

1

AUX_PANEL1

HDLED   RESET

PLED  PWRBTN

1

1

1

FRONT_LED_LAN1

1

1

SPEAKER1

1

1

NMI_BTN1

1

1

T   1

R

USB3_3

USB_1_2

1

1

TPM1

1

IPMB1

BMC_SMB_1

1

PECI1

1

NCSI1

1

BMC_DIS1

1

ME_RECOVERY1

1

CHASSIS_ID2

1

CHASSIS_ID3

1

CHASSIS_ID1

ATX12V1

SYSTEM_FAN1

SYSTEM_FAN2

SYSTEM_FAN3

RAID_1

1

2

1

3

4

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

6

5

7

8

9

10

11

13

15

16

17

18

19

20

22

14

38

39

40

41

42

43

44

45

46

47

48

49

1

AEP_1

12

1

SSATA_SGPIO1

21

Summary of Contents for D2143D8UM

Page 1: ...D2163D8UM D2143D8UM User Manual Version 1 0 Published September 2018 Copyright 2018 ASRock Rack INC All rights reserved ...

Page 2: ...or implied including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose In no event shall ASRock Rack its directors officers employees or agents be liable for any indirect special incidental or consequential damages including damages for loss of profits loss of business loss of data interruption of business and the like even if ASRock Rac...

Page 3: ...want to know more about ASRock Rack you re welcome to visit ASRock Rack s website at www ASRockRack com or you may contact your dealer for further information ASRock Rack Incorporation 6F No 37 Sec 2 Jhongyang S Rd Beitou District Taipei City 112 Taiwan R O C ...

Page 4: ...ion 13 2 1 Screw Holes 13 2 2 Pre installation Precautions 14 2 3 Installation of Memory Modules 15 2 4 Expansion Slot PCI Express Slots 16 2 5 Jumper Setup 17 2 6 Onboard Headers and Connectors 19 2 7 Dr Debug 25 2 8 LED Switches 26 2 9 Driver Installation Guide 26 2 10 M 2_SSD NGFF Module Installation Guide 27 Chapter 3 UEFI Setup Utility 29 3 1 Introduction 29 3 1 1 UEFI Menu Bar 29 3 1 2 Navig...

Page 5: ...iguration 43 3 3 8 Serial Port Console Redirection 45 3 3 9 H W Monitor 49 3 3 10 Runtime Error Logging 51 3 3 11 Intel SPS Configuration 53 3 3 12 Intel R VMD Technology 54 3 3 13 Intel R Virtual RAID on CPU 56 3 3 14 Instant Flash 57 3 4 Security 58 3 4 1 Key Management 59 3 5 Boot Screen 63 3 5 1 CSM Compatibility Support Module 65 3 6 Event Logs 66 3 7 Server Mgmt 68 3 7 1 System Event Log 69 ...

Page 6: ...formation 73 4 2 1 Running The Support CD 73 4 2 2 Drivers Menu 73 4 2 3 Utilities Menu 73 4 2 4 Contact Information 73 Chapter 5 Troubleshooting 74 5 1 Troubleshooting Procedures 74 5 2 Technical Support Procedures 76 5 3 Returning Merchandise for Service 76 Appendix Mezzanine Card Support List 77 ...

Page 7: ...erboard Micro ATX Form Factor 9 6 in x 9 6 in 24 4 cm x 24 4 cm Quick Installation Guide 1 x SATA3 Cable 60cm 1 x MINISAS Cable 12G 60cm 1 x Screw for M 2 Socket If any items are missing or appear damaged contact your authorized dealer Because the motherboard specifications and the BIOS software might be updated the con tent of this manual will be subject to change without notice In case any modif...

Page 8: ...IE6 x16 x8 switch with PCIE4 PCIe 3 0 x 8 1 PCIE4 x0 x8 switch with PCIE6 Storage SATA Controller Intel Xeon D 2100 12 x SATA3 6 0 Gb s 8 ports form SFF 8643 4 port from SATA 7 pin include 1 SATA DOM Ethernet Interface N A no onboard LAN X722 SoC integrated Please use a mezzanine type LAN card type A B C LAN Controller N A Management BMC Controller ASPEED AST2500 IPMI Intelligent Platform Manageme...

Page 9: ...res Plug and Play PnP ACPI 1 1 Compliance Wake Up Events SMBIOS 3 1 Support ASRock Rack Instant Flash Hardware Monitor Temperature CPU PCH DDR LAN Storage Temperature Sensing MB Card side TR1 Temperature Sensing Fan CPU Rear Front Fan Tachometer CPU Quiet Fan Allow Chassis Fan Speed Auto Adjust by CPU Temperature CPU Rear Front Fan Multi Speed Control Voltage Voltage Monitoring 12V 5V 3 3V CPU Vco...

Page 10: ... airflow through the heatsink is below 2CFM This motherboard supports Wake from on Board LAN To use this function please make sure that the Wake on Magic Packet from power off state is enabled in Device Manager Intel Ethernet Connection Power Management And the PCI Devices Power On is enabled in UEFI SETUP UTILITY Advanced ACPI Configuration After that onboard LAN1 2 can wake up S5 under OS If you...

Page 11: ... this utility you can press the F6 key during the POST or the F2 key to enter into the BIOS setup menu to access ASRock Rack Instant Flash Just launch this tool and save the new BIOS file to your USB flash drive floppy disk or hard drive then you can update your BIOS only in a few clicks without preparing an additional floppy diskette or other complicated flash utility Please be noted that the USB...

Page 12: ...64 bit 288 pin module Blue DDR4 DDR4_D1 DDR4 Blue 64 bit 288 pin module COM1 VGA1 PCIE6 MEZZ_MB_A1 MEZZ_MB_C1 MEZZ_MB_B1 M2_30 M2_42 M2_60 M2_80 M2_1 Dr Debug BAT1 1 AEP_2 SSATA_0 SSATA_2 SSATA_1 SSATA_3 SYSTEM_FAN4 1 SATAPWR2 PANEL1 1 AUX_PANEL1 HDLED RESET PLED PWRBTN 1 1 1 FRONT_LED_LAN1 1 1 SPEAKER1 1 1 NMI_BTN1 1 1 T 1 R USB3_3 USB_1_2 1 1 TPM1 1 IPMB1 BMC_SMB_1 1 PECI1 1 NCSI1 1 BMC_DIS1 1 M...

Page 13: ...pin DDR4 DIMM Slots DDR4_A2 DDR4_B2 15 CPU Fan Connector CPU_FAN1 16 2 x 288 pin DDR4 DIMM Slots DDR4_C2 DDR4_D2 17 2 x 288 pin DDR4 DIMM Slots DDR4_C1 DDR4_D1 18 NVMDIMM Mode Jumper AEP_2 19 M 2 Socket M2_1 Type 2230 2242 2260 2280 20 Clear CMOS Pad CLRMOS1 21 SATA SGPIO Connector SSATA_SGPIO1 22 System Fan Connector SYSTEM_FAN4 23 MINI SAS HD Connector SATA_0_7 24 SATA3 Connector SSATA_0 25 SATA...

Page 14: ...40 PCI Express 3 0 Card Slot 4 PCIE4 41 Speaker Header SPEAKER1 42 PCI Express 3 0 Card Slot 6 PCIE6 43 Virtual RAID On CPU Header RAID_1 44 CPU PECI Jumper PECI1 45 NCSI Mode Jumper NCSI_SEL1 46 Enable Disable BMC Jumper BMC_DIS1 47 Mezzanine Card Slot MEZZ_MB_A1 48 Mezzanine Card Slot MEZZ_MB_C1 49 Mezzanine Card Slot MEZZ_MB_B1 Please refer to Appendix for the information of the supported mezza...

Page 15: ... B USB1 IPMI LAN UID1 CLRMOS1 1 BMC AST2500 CPU1 BIOS ROM D2143D8UM D2163D8UM RoHS DDR4_C2 64 bit 288 pin module Blue DDR4 DDR4_C1 64 bit 288 pin module DDR4 Blue DDR4_D2 64 bit 288 pin module Blue DDR4 DDR4_D1 DDR4 Blue 64 bit 288 pin module COM1 VGA1 PCIE6 MEZZ_MB_A1 MEZZ_MB_C1 MEZZ_MB_B1 M2_30 M2_42 M2_60 M2_80 M2_1 Dr Debug BAT1 1 1 1 HDLED RESET PLED PWRBTN 1 1 1 1 1 1 1 1 1 USB3_3 1 1 1 BMC_...

Page 16: ...N5 failed 2 SB_PWR1 Green STB PWR ready 3 SYS_FAN3_LED Amber SYSTEM_FAN3 failed 4 SYS_FAN2_LED Amber SYSTEM_FAN2 failed 5 SYS_FAN1_LED Amber SYSTEM_FAN2 failed 6 CPU_FAN_LED Amber CPU_FAN1 failed 7 SYS_FAN4_LED Amber SYSTEM_FAN4 failed 8 BMC_LED1 Green BMC heartbeat LED ...

Page 17: ...rt LED Indications There are two LED next to the LAN port Please refer to the table below for the LAN port LED indications Dedicated IPMI LAN Port LED Indications Activity Link LED Speed LED Status Description Status Description Off No Link Off 10M bps connection or no link Blinking Yellow Data Activity Yellow 100M bps connection On Link Green 1Gbps connection ACT LINK LED SPEED LED LAN Port ...

Page 18: ...A NCSI Intel SoC Skylake D PCIe x16 MEZZ Connector Type A Type B Type C DDR4 ChannelA DDR4 ChannelB PCIe slot6 SIO NCT6791 BMC AST2500 Realtek 8211E RGMII VGA LPC TPM Header UART UART COM port Header TACH PWM System FAN Header CPU x1 Front x4 Rear x1 DDR4 ChannelE DDR4 ChannelD PCIe slot4 PCIe x8 SW BIO S 2280 4 pin Header Intel RAID key ...

Page 19: ...ated by circles to secure the motherboard to the chassis Attention Before installing this motherboard be sure to unscrew and remove the standoffs at the marked location under the motherboard from the chassis in order to avoid electri cal short circuit and damage to your motherboard Make sure to unplug the power cord before installing or removing the motherboard Failure to do so may cause physical ...

Page 20: ... to use a grounded wrist strap or touch a safety grounded object before you handle the compo nents 3 Hold components by the edges and do not touch the ICs 4 Whenever you uninstall any component place it on a grounded anti static pad or in the bag that comes with the component 5 When placing screws into the screw holes to secure the motherboard to the chassis please do not over tighten the screws D...

Page 21: ...s eight 288 pin DDR4 Double Data Rate 4 DIMM slots in two groups and supports Six and Dual Channel Memory Technology The DIMM only fits in one correct orientation It will cause permanent damage to the motherboard and the DIMM if you force the DIMM into the slot at incorrect orientation 1 2 3 ...

Page 22: ... Single PCIe Card x0 x16 Two PCIe Cards x8 x8 Installing an expansion card Step 1 Before installing an expansion card please make sure that the power supply is switched off or the power cord is unplugged Please read the documentation of the expansion card and make necessary hardware settings for the card before you start the installation Step 2 Remove the system unit cover if your motherboard is a...

Page 23: ...per cap is placed on these 2 pins Chassis ID Jumpers 3 pin CHASSIS_ID1 see p 6 No 6 3 pin CHASSIS_ID2 see p 6 No 4 3 pin CHASSIS_ID1 see p 6 No 3 Single Motherboard Indication Default System Level ME Recovery Jumper 3 pin ME_RECOVERY1 see p 6 No 2 Normal Mode Default ME Recovery Mode CPU PECI Mode Jumper 3 pin PECI1 see p 6 No 44 CPU PECI connect to PCH CPU PECI connect to BMC Default NVMDIMM Mode...

Page 24: ...power header SATAPWR1 and there is no need to change the default jumper setting of the SATA DOM Power Jumper pins 2 3 Warning Incorrect setting of the SATA DOM Power Jumper SATAPWR1 may cause dam age to the motherboard or your SATA DOM Enable Disable BMC Jumper 3 pin BMC_DIS1 see p 6 No 46 Normal Mode Default BMC Enabled BMC Disabled NCSI Mode Jumper 3 pin NCSI_SEL1 see p 6 No 45 No Function NCSI ...

Page 25: ...n off your system using the power switch RESET Reset Switch Connect to the reset switch on the chassis front panel Press the reset switch to restart the computer if the computer freezes and fails to perform a normal restart PLED System Power LED Connect to the power status indicator on the chassis front panel The LED is on when the system is operating The LED is off when the system is in S4 sleep ...

Page 26: ...se two 2 pin headers allow you to use the Gigabit internet indicator cable to connect to the LAN status indicator When this indicator flickers it means that the internet is prop erly connected C Chassis intrusion pin 2 pin CHASSIS This header is provided for host computer chassis with chassis intrusion detection designs In addition it must also work with external detection equipment such as a chas...

Page 27: ...N1 see p 6 No 15 GND FAN_VOLTAGE CPU_FAN_SPEED FAN_SPEED_CONTROL 1 2 3 4 This motherboard provides one 4 Pin CPU fan Quiet Fan connector If you plan to connect a 3 Pin CPU fan please connect it to Pin 1 3 For more details please refer to the Cooler QVL list on the ASRock Rack website System Connectors 4 pin SYSTEM_FAN1 see p 6 No 11 4 pin SYSTEM_FAN2 see p 6 No 10 4 pin SYSTEM_FAN3 see p 6 No 9 4 ...

Page 28: ...7 3V 3V GND GND 5V 5V GND PWROK_PS 5VSB 12V 12V 3V 12 1 13 24 3V 12V GND PSON GND GND GND 5V 5V 5V GND N A This motherboard provides a 24 pin ATX power connector To use a 20 pin ATX power supply please plug it along Pin 1 and Pin 13 ATX 12V Power Connector 8 pin ATX12V1 see p 6 No 8 4 8 1 5 12V GND This motherboard provides two 8 pin ATX 12V power connectors USB 3 0 Connector USB3_5 see p 6 No 34 ...

Page 29: ...itor its temperature Baseboard Management Controller SMBus Header 5 pin BMC_SMB1 see p 6 No 39 BMC_SMB_PRESENT_1_N Power BMC_SMBCLK GND BMC_SMBDATA The header is used for the SM BUS devices Intelligent Platform Management Bus Header 4 pin IPMB1 see p 6 No 38 IPMB_SDA IPMB_SCL GND No connect This 4 pin connector is used to provide a cabled base board or front panel connection for value added featur...

Page 30: ...curity protects digital identities and ensures platform integrity Front LAN LED Connector FRONT_LED_LAN1 see p 6 No 33 1 LAN3_LINK LED_PWR LED_PWR LAN4_LINK These 4 pin connectors are used for the front LAN status indicator Serial Port Header 9 pin COM2 see p 6 No 37 CCTS 1 RRTS 1 DDSR 1 DDTR 1 RRXD1 GND TTXD1 DDCD 1 1 RRI 1 This COM header supports a serial port module Serial General Purpose Inpu...

Page 31: ... install PCI E devices or try installing them in other slots If the problem still exists please remove all PCI E devices or try using another VGA card A0 A7 Problem related to IDE or SATA devices Please re install IDE and SATA devices If the problem still exists please clear CMOS and try removing all SATA devices b0 Problem related to memory Please re install the CPU and memory If the problem stil...

Page 32: ...D button again to turn off the indicator 2 9 Driver Installation Guide To install the drivers to your system please insert the support CD to your optical drive first Then the drivers compatible to your system can be auto detected and listed on the support CD driver page Please follow the order from top to bottom to install those required drivers Therefore the drivers you install can work properly ...

Page 33: ... M 2 Socket M2_1 supports a M 2 PCI Express module up to Gen 3 x4 6Gb s Installing the M 2_SSD NGFF Module Step 1 Prepare a M 2_SSD NGFF module and the screw 1 2 3 4 NUT1 NUT2 NUT3 NUT4 Step 2 Depending on the PCB type and length of your M 2_SSD NGFF module find the corresponding nut location to be used No 1 2 3 4 Nut Location NUT30 NUT42 NUT60 NUT80 PCB Length 3cm 4 2cm 6cm 8cm Module Type Type 2...

Page 34: ... NUT2 NUT3 NUT4 Step 4 Peel off the yellow protective film on the nut to be used Hand tighten the standoff into the desired nut location on the motherboard Step 5 Gently insert the M 2 NGFF SSD module into the M 2 slot Please be aware that the M 2 NGFF SSD module only fits in one orientation NUT1 NUT2 NUT3 NUT4 Step 6 Tighten the screw with a screwdriver to secure the module into place Please do n...

Page 35: ...ar The top of the screen has a menu bar with the following selections Item Description Main To set up the system time date information Advanced To set up the advanced UEFI features Security To set up the security features Boot To set up the default system device to locate and load the Operating System Event Logs For event log configuration Server Mgmt To manage the server Exit To exit the current ...

Page 36: ...e selected items Tab Switch to next function Enter To bring up the selected screen PGUP Go to the previous page PGDN Go to the next page HOME Go to the top of the screen END Go to the bottom of the screen F1 To display the General Help Screen F7 Discard changes and exit the UEFI SETUP UTILITY F9 Load optimal default values for all the settings F10 Save changes and exit the UEFI SETUP UTILITY F12 P...

Page 37: ...1 English 3 2 Main Screen Once you enter the UEFI SETUP UTILITY the Main screen will appear and display the system overview The Main screen provides system overview information and allows you to set the system time and date ...

Page 38: ...onfigurations for the following items CPU Configuration DRAM Configuration Chipset Configuration Storage Configuration ACPI Configura tion USB Configuration Super IO Configuration Serial Port Console Redirection H W Monitor Runtime Error Logging Intel SPS Configuration Intel R VMD Technology Intel R Virtual RAID on CPU and Instant Flash ...

Page 39: ...r compatibility issues with some power supplies Please set this item to Disabled if above issues occur Intel Turbo Boost Technology Intel Turbo Boost Technology enables the processor to run above its base operating fre quency when the operating system requests the highest performance state Long Duration Power Limit Configure Package Power Limit 1 in watts When the limit is exceeded the CPU ratio w...

Page 40: ...licious buffer overflow attacks Enable Intel TXT Support Enables Intel Trusted Execution Technology Configuration Intel Virtualization Technology Intel Virtualization Technology allows a platform to run multiple operating systems and applications in independent partitions so that one computer system can function as multiple virtual systems Enable SMX Use this item to enable Safer Mode Extensions D...

Page 41: ...ption Hardware P States Disable Hardware chooses a P state based on OS Request Legacy P States Native Mode Hardware chooses a P state based on OS guidance Out of Band Mode Hardware autonomously chooses a P state no OS guidance AES NI Use this item to enable or disable AES NI support CPU Thermal Throttling Enable CPU internal thermal control mechanisms to keep the CPU from overheating ...

Page 42: ...memory module s inserted and assign the appropriate frequency automatically Channel Interleaving Select to configure Channel Interleaving settings Rank Interleaving Select to configure Rank Interleaving settings Mirror Mode Mirror Mode will set entire 1LM 2LM memory in system to be mirrored consequently reducing the memory capacity by half Mirror Enable will disable XPT Prefetch Memory Rank Sparin...

Page 43: ...imary Graphics Adapter If PCI Express graphics card is installed on the motherboard you may use this option to select PCI Express or Onboard VGA as the primary graphics adapter If no PCI Express graphics card is installed Onboard VGA is the default graphics adapter There is no screen on monitor even if a HDMI display is connected Select Onboard Hdmi instead to use HDMI as output source Onboard VGA...

Page 44: ..._AB Link Width This presents MEZZ_MB_AB Link Width The default value is x16 MEZZ_MB_AB Link Speed This allows you to select MEZZ Link Speed The default value is Auto MEZZ_MB_AB ASPM Support This option enables or disables the ASPM support for all CPU downstream devices SR IOV Support If system has SR IOV capable PCIe Devices this option Enables or Disables Single Root IO Virtualization Support Res...

Page 45: ...SATA Controllers SATA Mode Selection Identify the SATA port is connected to Solid State Drive or Hard Disk Drive Press Ctrl I to enter RAID ROM during UEFI POST process SATA ALPM Use this item to enable or disable Support Aggressive Link Power Management SATA Port 0 1 2 3 4 5 6 7 Depending on how many SATA ports you have you will see SATA_x x means number listed on the screen with its status indic...

Page 46: ... enter RAID ROM during UEFI POST process sSATA ALPM Use this item to enable or disable Support Aggressive Link Power Management sSATA Port 0 1 2 3 M2_1 sSATA M2_1 PCIE Depending on how many SATA ports you have you will see sSATA_x x means number listed on the screen with its status indicated as sSATA device Model Name or Not Detected ...

Page 47: ...ed up by a PCIE device and enable wake on LAN Ring In Power On Use this item to enable or disable Ring In signals to turn on the system from the powersoft off mode RTC Alarm Power On Allow the system to be waked up by the real time clock alarm Set it to By OS to let it be handled by your operating system ...

Page 48: ... Enable or disable Legacy OS Support for USB 2 0 devices If you encounter USB compatibility issues it is recommended to disable legacy USB support Select UEFI Setup Only to support USB devices under the UEFI setup and Windows Linux operating systems only ...

Page 49: ...ble the serial port COM Change Settings Use this item to select an optimal setting for Super IO device SOL Configuration Use this item to set parameters of SOL Serial Port Use this item to enable or disable the serial port COM Change Settings Use this item to select an optimal setting for Super IO device Serial Port 2 Configuration Use this item to set parameters of COM2 ...

Page 50: ...44 English Serial Port Use this item to enable or disable the serial port COM Change Settings Use this item to select an optimal setting for Super IO device ...

Page 51: ...igure Console Redirection Settings and specify how your computer and the host computer to which you are connected exchange information Both computers should have the same or compatible settings Terminal Type Use this item to select the preferred terminal emulation type for out of band management Option Description VT100 ASCII character set VT100 Extended VT100 that supports color and function keys...

Page 52: ... item indicates the end of a serial data packet The standard setting is 1 Stop Bit Select 2 Stop Bits for slower devices Flow Control Use this item to set the flow control to prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to restart the flow Hardware flo...

Page 53: ...ou are connected exchange information Out of Band Mgmt Port Microsoft Windows Emergency Management Services EMS allows for remote management of a Windows Server OS through a serial port Terminal Type Use this item to select the preferred terminal emulation type for out of band management It is recommended to select VT UTF8 Option Description VT100 ASCII character set VT100 Extended VT100 that supp...

Page 54: ...48 English CTS and Software Xon Xoff Data Bits Parity Stop Bits ...

Page 55: ...ll controlled by BMC If Manual is selected configure the items below CPU_FAN1 This allows you to set the CPU fan1 s speed The default value is Smart Fan SYSTEM_FAN1 This allows you to set the System fan1 s speed The default value is Smart Fan SYSTEM_FAN2 This allows you to set the System fan2 s speed The default value is Smart Fan SYSTEM_FAN3 This allows you to set the System fan3 s speed The defa...

Page 56: ...mart fan s level speed Smart Fan Duty Control Smart Fan Duty x x means 1 to 11 stage This allows you to set duty cycle for each stage Smart Fan Temp Control Smart Fan Temp x x means 1 to 11 stage This allows you to set temperature for each stage Watch Dog Timer This allows you to enable or disable the Watch Dog Timer The default value is Disabled ...

Page 57: ...log features S W Error Injection Support When it is set to Enabled S W Error Injection is supported by unlocking MSR Ox790 Memory Error Memory enabling and logging setup option Correctable Error Threshold Correctable Error Threshold 0 0x7FFF used for sparing tagging and leaky bucket PCIE Corrected Error Enable Use this item to enable or disable PCIe Correctable errors PCIE Corrected Error Threshol...

Page 58: ...52 English PCIE Uncorrected Error Enable Use this item to enable or disable PCIe Uncorrectable errors PCIE Fatal Error Enable Use this item to enable or disable PCIe Fatal errors ...

Page 59: ...D2163D8UM D2143D8UM 53 English 3 3 11 Intel SPS Configuration SPS screen displays the Intel SPS Configuration information such as Operational Firmware Version and Firmware State ...

Page 60: ...wed to configure the options below VMD port 1A Use this item to enable or disable Intel R Volume Management Device Technology on specific root port VMD port 1B Use this item to enable or disable Intel R Volume Management Device Technology on specific root port VMD port 1C Use this item to enable or disable Intel R Volume Management Device Technology on specific root port VMD port 1D Use this item ...

Page 61: ...D2163D8UM D2143D8UM 55 English specific root port Hot Plug Capable Use this item to enable or disable Hot Plug for PCIe Root Ports 1A 1D ...

Page 62: ...56 English 3 3 13 Intel R Virtual RAID on CPU This formset allows the user to manage Intel R Virtual RAID on CPU ...

Page 63: ...ve floppy disk or hard drive and launch this tool then you can update your UEFI only in a few clicks without preparing an additional floppy diskette or other compli cated flash utility Please be noted that the USB flash drive or hard drive must use FAT32 16 12 file system If you execute Instant Flash utility the utility will show the UEFI files and their respective information Select the proper UE...

Page 64: ...to remove the password User Password Set or change the password for the user account Users are unable to change the settings in the UEFI Setup Utility Leave it blank and press enter to remove the password Secure Boot Use this to enable or disable Secure Boot Control The default value is Disabled Enable to support Windows Server 2012 R2 or later versions Secure Boot Secure Boot Mode Secure Boot mod...

Page 65: ...ear Secure Boot keys Force System to Setup Mode clear all Secure Boot Variables Change takes effect after reboot Export Secure Boot variables Copy NVRAM content of Secure Boot variables to files in a root folder on a file system device Enroll Efi Image Allow the image to run in Secure Boot mode Enroll SHA256 Hash certificate of a PE image into Authorized Signature Database db Remove UEFI CA from D...

Page 66: ...icated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed Key Exchange Keys Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed Authorized Signatures Enro...

Page 67: ...ificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Factory External Mixed Authorized TimeStamps Enroll Factory Defaults or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384...

Page 68: ...s or load certificates from a file 1 Public Key Certificate in a EFI_SIGNATURE_LIST b EFI_CERT_X509 DER encoded c EFI_CERT_RSA2048 bin d EFI_CERT_SHA256 384 512 2 Authenticated UEFI Variable 3 EFI PE COFF Image SHA256 Key Source Default External Mixed Test ...

Page 69: ...Use this item to set the system boot order Boot Option 2 Use this item to set the system boot order Boot Option 3 Use this item to set the system boot order Boot Option Filter This option controls Legacy UEFI ROMs priority USB Device BBS Priorities This page will show only when system install USB Storage Setup Prompt Timeout Configure the number of seconds to wait for the UEFI setup utility ...

Page 70: ...tem boots up Please note that a buzzer is needed Full Screen Logo Enable to display the boot logo or disable to show normal POST messages AddOn ROM Display Use this option to adjust AddOn ROM Display If you enable the option Full Screen Logo but you want to see the AddOn ROM information when the system boots please select Enabled Configuration options Enabled and Disabled The default value is Enab...

Page 71: ...ption ROM only Select Legacy only to run those that support legacy option ROM only Select Do not launch to not execute both legacy and UEFI option ROM Launch Other Storage OpROM Policy Select UEFI only to run those that support UEFI option ROM only Select Legacy only to run those that support legacy option ROM only Select Do not launch to not execute both legacy and UEFI option ROM Launch Video Op...

Page 72: ...isabled with NVMe device but it is Legacy with other devices This item can t select Video Option ROM policy Mezz_MB_C Slot OpROM Use this item to select slot storage and Network Option ROM policy In Auto option the default is Disabled with NVMe device but it is Legacy with other devices This item can t select Video Option ROM policy PCIE M2_1 Slot OpROM Use this item to select slot storage and Net...

Page 73: ...boot Erase Event Log The options include No Yes Next reset and Yes Every reset If Yes is selected all logged events will be erased When Log is Full Use this item to choose options for reactions to a full Smbios Event Log The options include Do Nothing and Erase Immediately Log System Boot Event Choose option to enable disable logging of System boot event View Smbios Event Log Press Enter to view t...

Page 74: ... specified time out BMC starts at the same time when BIOS starts during AC power ON It takes around 90 seconds to initialize Host to BMC interfaces Inventory Support This will execute inventory function for system Enabling this item will take some time at system boot ...

Page 75: ...vent logging for error progress codes during boot Erase SEL Use this to choose options for earsing SEL When SEL is Full Use this to choose options for reactions to a full SEL Log EFI Status Codes Use this item to disable the logging of EFI Status Codes or log only error code or only progress code or both ...

Page 76: ...ddress toggle to Yes and the changes take effect after the system reboots The default value is No Configuration Address Source Select to configure BMC network parameters statically or dynamically by BIOS or BMC Configuration options Static and DHCP Static Manually enter the IP Address Subnet Mask and Gateway Address in the BIOS for BMC LAN channel configuration DHCP IP address Subnet Mask and Gate...

Page 77: ... web interface is Username admin Password admin For more instructions on how to set up remote control environment and use the IPMI man agement platform please refer to the IPMI Configuration User Guide or go to the Support website at http www asrockrack com support ipmi asp ...

Page 78: ...ssage Discard changes and exit setup will pop out Press ESC key or select Yes to exit the UEFI SETUP UTILITY without saving any changes Discard Changes When you select this option the following message Discard changes will pop out Press F7 key or select Yes to discard all changes Load UEFI Defaults Load UEFI default values for all the setup questions F9 key can be used for this operation Boot Over...

Page 79: ...The CD automatically displays the Main Menu if AUTORUN is enabled in your computer If the Main Menu does not appear automatically locate and double click on the file ASRSetup exe from the root folder in the Support CD to display the menu 4 2 2 Drivers Menu The Drivers Menu shows the available device s drivers if the system detects installed devices Please install the necessary drivers to activate ...

Page 80: ...ettings 3 Check the settings of the 115V 230V switch on the power supply 4 Verify if the battery on the motherboard provides 3VDC Install a new battery if it does not If there is no video 1 Try replugging the monitor cables and power cord 2 Check for memory errors If there are memory errors 1 Verify that the DIMM modules are properly seated in the slots 2 Use recommended DDR3 1600 1333 1066 ECC DI...

Page 81: ...ify if the battery on the motherboard provides 3VDC Install a new battery if it does not 2 Confirm whether your power supply provides adaquate and stable power Other problems 1 Try searching keywords related to your problem on ASRock Rack s FAQ page http www asrockrack com support ...

Page 82: ...of your invoice marked with the date of purchase is required By calling your vendor or going to our RMA website http event asrockrack com tsd asp you may obtain a Returned Merchandise Authorization RMA number The RMA number should be displayed on the outside of the shipping carton which is mailed prepaid or hand carried when you return the motherboard to the manufacturer Shipping and handling char...

Page 83: ...pe A M599 LAN Card Mezz Type A M599R v2 0 or above LAN Card Mezz Type A M710 LAN Card Mezz Type A MX710R LAN Card Mezz Type A MCX3 LAN Card Mezz Type A MCX4LX Storage Card Mezz Type A M3008S PHY Card Mezz Type C MP 557R2 PHY Card Mezz Type C MP 557R4 PHY Card Mezz Type C MP 1543R4 PHY Card Mezz Type C MP 4223R4 PHY Card Mezz Type C MP 4227R2 Please refer to our website for the latest support list ...

Reviews: