2. SAFETY PRECAUTIONS

INTENDED USE OF THE PRODUCT

The Aspire Swift Patient Mover has been 
designed to transfer human patients with 
the assistance of one carer or attendant.
The Aspire Swift Patient Mover should 
only be used with Aspire approved 
standing slings, which have been chosen 
and assessed by a competent trained 
health professional. For a complete list of 
all compliant lifting slings please contact 
Aidacare on 1300 133 120.
IMPORTANT – only approved slings and 
accessories are compatible with this 
lifter. If you are unsure please contact 
Aidacare on 1300 133 120.
The correct and appropriate use of the 
Aspire Swift Patient Mover reduces the 
risks associated with manual patient 
handling. The lifting and transferring of 
patients should always be assessed and 
planned by a trained health professional.

SAFETY CONSIDERATIONS

ALWAYS 

ensure that attendants have 

read this guide before operating this 
patient mover.

ALWAYS

 use slings that are assessed 

and considered suitable by a trained 
healthcare professional.

ALWAYS

 ensure the area around the 

patient mover and patient is clear of 
obstructions.

ALWAYS

 minimise the distance over 

which the patient is being transferred by 
positioning support surfaces as close as 
possible. 

ALWAYS

 ensure braking castors are 

locked when performing transfers in and 
out of the patient mover.

DO NOT

 operate the patient mover 

without correct manual handling training. 
IF IN DOUBT DO NOT USE.

DO NOT

 use the patient mover where 

any doubt exists regarding the safety 
of the patient mover including but not 
limited to wear or damage with particular 
importance to be placed on the standing 
sling attachment points.

DO NOT 

use the patient mover with 

slings showing any signs of wear or 
damage, including fraying

.

DO NOT 

exceed the 185kg safe working 

load of the Aspire Swift Patient Mover.

DO NOT

 leave user unattended at any 

time.

3. PARTS GLOSSARY

1

2

3

4

5

6

7

10

8

9

1

Push Handle

2

Hand Rail

3

Push Handle 

4

Sling Attachment 

5

Seat Pad 

6

Knee Pad

7

Footplate 

8

Castor Wheel

9

Foot Pedals

10

Sling Attachment

Summary of Contents for Swift Patient Mover

Page 1: ...swift USER MANUAL Swift Patient Mover swift ...

Page 2: ...ranty Service_____________ 18 11 Troubleshooting _______________ 19 12 Specifications__________________ 20 13 Service Log Book ______________ 21 1 OVERVIEW IMPORTANT Do not use the Aidacare Aspire Swift Patient Mover without having first read this manual The Aspire Swift Patient Mover provides a safe and easy solution for a carer wishing to transfer a client This mobile standing and transport aid ...

Page 3: ...ng this patient mover ALWAYS use slings that are assessed and considered suitable by a trained healthcare professional ALWAYS ensure the area around the patient mover and patient is clear of obstructions ALWAYS minimise the distance over which the patient is being transferred by positioning support surfaces as close as possible ALWAYS ensure braking castors are locked when performing transfers in ...

Page 4: ... Ensure the pads rotate smoothly with minimum effort and no excess play 1 2 3 4 5 6 5mm Hexagonal Key 8mm Hexagonal Key 13mm Socket 14mm Socket Ratchet 17mm Open ended spanner 1 1 x Base Unit 2 1 x Right hand frame M10 x 25 Socket head bolt Washer 3 1 x Left hand frame 4 1 x Knee pad with 4 x plastic spacer 4 Steel M8 washers and 4 x button head M8 bolts 5 1 x Right hand seat pad 6 1 x Left hand s...

Page 5: ...by securing all 4 x bolts in place The knee pad should not slide up or down if positioned correctly 12 Locate sling anchor bolt 9 10 11 12 13 14 13 Insert sling anchor bolt into side of push handle Tighten and secure pin by locking into foam centre handle This bolt also secures the foam handle in place 14 Secure the side frame to the base unit by inserting the large washer and locking in place wit...

Page 6: ... using the push handles as shown below 6 GENERAL OPERATION 5 PRELIMINARY CHECKS After assembling the patient mover these checks should be completed prior to initial use 1 Check the seat pads are secure and rotate back and forth for safe transfers 2 Check that locking castors engage and disengage 3 Check that the leg mechanism works correctly by pressing on the foot pedals 4 If using a sling ensure...

Page 7: ...m the footplate and the carer can remove the castor brakes and wheel the Swift Patient Mover away 3 4 5 Sling Attachment Knee Pad Adjustment Sling and transfer belt attachments are provided for users who require extra support See page 16 for Aspire Slings approved for use on the Swift Patient Mover 1 The Knee Pad on the Swift Patient Mover can be adjusted for height and angle To adjust the angle l...

Page 8: ...ition the user so they are facing the Swift Patient Mover whilst sitting on the bed with their feet on the floor 2 Spread the legs if required and get the user to place their feet on the footplate Flip up the Seat Pads and apply the Castor Brakes 3 The user should grab the Hand Rail with both hands and use this to assist them with standing 4 Once the user is fully stood up the carer should flip do...

Page 9: ...NANCE GUIDE CHECK LIST Check castors are fastened securely to the frame Castors should run and swivel smoothly if hair or other fibres have built up within the castor this should be removed Check that the brakes on the rear castors function normally Clean surfaces with a pH neutral detergent chorine and phenol based detergents should not be used as these may damage Patient Mover components All mov...

Page 10: ...K TO BASE WARRANTIES MEANING THAT ANY PARTS OR WHOLE LIFTERS REQUIRING REPAIR NEED TO BE RETURNED TO THE NEAREST AIDACARE SERVICE CENTRE AT THE CUSTOMER S EXPENSE PLEASE CONTACT AIDACARE FOR A CURRENT LIST OF SERVICE CENTRE LOCATIONS SPARE PARTS SPARE PARTS LIST AVAILABLE UPON REQUEST FROM AIDACARE ON 1300 130 122 or www aidacarelifters com au 11 TROUBLESHOOTING WARNING TROUBLESHOOTING SHOULD ONLY...

Page 11: ..._______________________________________ Inspected by _____________________ Signature __________________________ Action taken ________________________________________________________ Date __________________________ Date __________________________ YEAR 4 Service Type ________________________________________________________ Condition Report ____________________________________________________ _______...

Page 12: ...Imported by AIDACARE P L 4 Noonan Rd Ingleburn NSW 2565 T 1300 133 120 W www aidacare com au swift ASUM25 7 240918 ...

Reviews: