Summary of Contents for prodis INC

Page 1: ...Installation and operation manual EN prodis INC Digital Process Meter for incremental position and angle sensors Please read carefully before installation and operation ...

Page 2: ... ASM Automation Sensorik Messtechnik GmbH 2019 All rights reserved Am Bleichbach 18 24 85452 Moosinning Germany ...

Page 3: ...ctions 4 1 1 Signal words and symbols 4 1 2 Intended use 5 2 Transport and storage 5 3 Installation and initial operation 6 3 1 Mechanical installation 6 3 2 Electrical connection 7 3 3 Startup 15 4 Operation 16 5 Maintenance and disposal 21 5 1 Maintenance and service 21 5 2 Disposal 21 ...

Page 4: ... or Death Indicates a situation that can result in serious personal injury or death if not properly avoided WARNING Risk of Personal Injury or Death Indicates a situation that can result in moderate personal injury or death if not properly avoided WARNING Risk of Personal Injury Indicates a situation that can result in minor personal injury if not properly avoided WARNING Risk of Property Damage I...

Page 5: ...ata sheet of the respective Process Meter is part of this instruction manual If not yet available it may be requested by stating the respective model name Pos 11 Bedienungsanl eitungen Prodis Tr ansport und Lagerung 6 mod_1508933116286_78 docx 49279 1 1 2 Transport and storage Observe storage and transport temperatures according to the operating temperature see data sheet Max rel humidity 80 conde...

Page 6: ...l operation Pos 15 Bedienungsanl eitungen Prodis M echanische Befestigung 7 mod_1542119710123_78 docx 59575 2 1 3 1 Mechanical installation Cutout according to DIN 43700 Maximum material thickness 5 mm 197 1 Push the device into the front panel cutout as far as it will go 2 Hook the mounting clamp to the rear notch 3 Push down the end of the mounting clamp until the front notch is locked ...

Page 7: ...aranteed that the excitation voltage agrees with the indicated value on the type label Do not open the process meter Pos 17 D atenblätter Pr odis Eigenschaften Redesign Prodis_Eigenschaften_INC 5 mod_1499766517119_78 docx 44717 1 Description and specifications prodis INC is designed for use with incremental position sensors to display angles and displacements The fast counter processes 90 phase sh...

Page 8: ...ge temperature 20 85 C Weight 24 V DC approx 250 g 230 V AC approx 400 g Protection class Front IP60 rear IP40 Humidity Max 80 R H non condensing Safety of equipment Directive 2014 35 EU EN 61010 1 2010 EMC Directive 2014 30 EU EN 61326 1 2013 Programmable parameters value range Value range display offset limit values 999999 to 999999 Divisor Multiplier 0 to 999999 Other programmable parameters Co...

Page 9: ...arator function with two relays and four NPN open collector outputs are available With the RS 232 interface data can be transmitted easily to a PC printer or PLC Quadrature signal A Quadrature signal B Zero or Index signal Z Reference signal T multiple function The reset of the display takes place for the condition A B Z resp A B Z T The Zero signal is a pulse signal unique within the measurement ...

Page 10: ...nector X2 Pin no Sensor excitation UB 1 Sensor excitation 0 V GND 2 Signal A 4 Signal A 5 Signal B 6 Signal B 7 Signal Z zero signal 8 Signal Z zero signal 9 Signal T reference signal 10 Signal T reference signal 11 GND 12 PD INC 24VDC Excitation 24 V Excitation 0 V GND 13 14 PD INC 230VAC Excitation Protective ground 13 15 14 Signals D Sub pin no TxD 2 RxD 3 GND 5 Rear view without comparator out...

Page 11: ... X1 Pin no Connector X2 Pin no Sensor excitation UB 1 Sensor excitation 0 V GND 2 Signal A 4 Signal A 5 Signal B 6 Signal B 7 Signal Z zero signal 8 Signal Z zero signal 9 Signal T reference signal 10 Signal T reference signal 11 GND 12 PD ADC 24VDC Excitation 24 V Excitation 0 V GND 13 14 PD ADC 230VAC Excitation 24 V Protective ground 13 15 14 Signals Connector X3 Pin no TxD 17 RxD 16 GND 18 Rea...

Page 12: ...1 NPN1 20 Relay 1 NO NC Common 25 27 26 LED1 Comparator 2 NPN2 21 Relay 2 NO NC Common 28 30 29 LED2 Comparator 3 NPN3 22 Comparator 4 NPN4 23 NPN GND NPN U8 24V 24 19 Pos 24 D atenblätter Pr odis Maßzeichnungen PD IN C Desktopversi on 0 mod_1392286314904_78 docx 5321 4 1 Desktop version option DT Wiring of connector X1 see table Wiring basic unit Pos 25 Sei tenumbruch 0 mod_1353584168894_0 docx 3...

Page 13: ...eter PD INC Version 2 1 0 www asm sensor com 13 Pos 26 Bedienungsanl eitungen Prodis Schaltausgänge_Diagramm 6 mod_1508147960045_78 docx 48599 1 Comparator outputs diagram Pos 27 Sei tenumbruch 0 mod_1353584168894_0 docx 336 1 ...

Page 14: ...on value Send to prodis r Response of prodis CR sign n5 n4 n3 n2 n1 n0 with ni ASCII characters leading digits filled with 0 Sign positive sign Space Tare function On Off Send to prodis n prodis function Tare function on off Data format 1 start bit 8 data bits 1 stop bit no parity Baud rate programmable Net transmission rate Max 50 s approx Pos 29 Sei tenumbruch 0 mod_1353584168894_0 docx 336 1 ...

Page 15: ...ifferential POSIMAG TTL HTL Sensor with Line driver 5V differential or RS485 reference switch Pos 31 Bedienungsanl eitungen Prodis Inbetriebnahme INC 6 mod_1508319961613_78 docx 48835 2 1 3 3 Startup When the meter is switched on a short self test sequence will start with all LED segments on and then the version of the process meter will be displayed After that procedure prodis INC is in the norma...

Page 16: ...volatile memory Multifunction key for parameter settings Multifunction key for parameter settings means hold the key and press Pos 35 Bedienungsanl eitungen Prodis Tasten_Funkti onen 6 mod_1508153265378_78 docx 48659 1 Explanation and operation of the functions Parameter settings The parameter settings are effected in a programming menu Key key combination Function Activate programming mode Change...

Page 17: ... Counting direction drEh L r left right L T signal t oFF CS CF Hn AF tl brEF Ctr3 Ctr4 oFF Last value memory ISt 1 0 0 Display brightness db 1 15 15 Transmission rate bA 4 8 9 6 115 2 9 6 Relative measurement mode Flashing decimal point 0 Reset Offset oFFSEt 999999 999999 000000 Limit value rELx 999 999 999 999 Hysteresis Hµ rELx 999 999 1 Operating direction rx oEF SCH SCH Measurement mode rx HAU...

Page 18: ...ith the parameter CHnul CHnul 1 the display will be set to zero when relative measurement is activated Offset function The offset function allows setting and changing of the offset value directly in the normal mode Comparator function for versions with comparator function only Up to four comparator functions can defined by programming of limit value hysteresis and operating direction Outputs are t...

Page 19: ...e resolution of the position sensor dX displacement per counting edge and calculate it to the unit to be displayed Define the resolution of the meter dA same unit as dx Multiplier dX Divisor dA Insert and transform multiplier and divisor by extension or reduction Set decimal point With the decimal divisor an additional shift right can be made As an alternative to the resolution parameters dX and d...

Page 20: ...the meter dA 0 01 inch Multiplier dX 0 005 25 4 Divisor dA 0 01 Insert the values and extend reduce Multiplier 5 Divisor 254 Set decimal point between the second and the third digit from the right hand side 3 Meter for incremental encoder with 2500 pulses per revolution LSD of the display has to be equivalent to 0 1 degrees Resolution of the sensor with times 4 counting mode dX 4 2500 pulses revol...

Page 21: ...d_1536755341289_78 docx 58627 2 1 5 1 Maintenance and service The prodis process meters do not contain any components that can be repaired by the customer Do not open the housing The prodis process meter must not be modified Deinstallation Disconnect electrical connections Loosen fixing screws Pos 46 Bedienungsanl eitungen Prodis Entsorgung _PD 6 mod_1508829083628_78 docx 49075 2 1 5 2 Disposal Di...

Page 22: ...prodis Digital Process Meter PD INC 22 Version 2 1 0 www asm sensor com ...

Page 23: ...prodis Digital Process Meter PD INC Version 2 1 0 www asm sensor com 23 ...

Page 24: ...nik GmbH 2019 All rights reserved Subject to changes without notice See protection note DIN34 ASM Sensors Inc 650 W Grand Ave Unit 205 Elmhurst IL 60126 USA Tel 1 630 832 3202 Fax 1 630 832 3204 info asmsensors com ASM Sales Office UK Tanyard House High Street Measham Derbs DE12 7HR United Kingdom Tel 44 845 1222 123 Fax 44 845 1222 124 info asm sensor com www asm sensor com ...