positilt
®
Inclination Sensors PTM series
Gyro-compensated Inclination Sensors PTK series
6
Version 1.0.0
www.asm-sensor.com
Pos: 19 /Bedienungsanl eitungen/Positilt/Elektr. Anschl uss_PT K @ 9\m od_1587620105034_78.docx @ 71686 @ 2 @ 1
3.2 Electrical connection
Damage or destruction of the sensor due to excessive operating voltage or
mounting error
•
The applied operating voltage must not exceed the value specified in the data
sheet.
•
Operate the sensor only within the limits specified in the data sheet.
•
Connect to the power supply only by qualified personnel and in accordance with
the applicable safety regulations for electrical equipment.
•
Do not connect or disconnect the sensor under voltage!
Corrosion in the sensor due to moisture penetration
•
Use the sensor only according to protection class.
•
The mating connector should have the same protection class as the sensor,
otherwise the lower protection class of the mating connector is valid.
•
Avoid crossing the dew point.
•
Cable outputs must be installed in such a way that no moisture can get into the
cable.
•
The protection class of sensors with connector output is valid only if the electrical
plug is connected!
Damage of the sensor cable due to mechanical stress
•
Do not twist the M12 connector inserts.
•
It is important that the knurled nuts on the connectors are tightened to the correct
torque for each different size of the connector:
•
M12-ASM connectors / couplings: 1.0 Nm
•
connectors / couplings of other manufacturers: according to manufacturer
instruction.
•
Use a torque wrench.
•
Do not strain the connection cable.
•
A separate cord grip is recommended.