ASM 925 Operator Instructions Download Page 3

3) Press 1 to continue and you can edit the run number by selecting 2 or it will sequentially 
increase each time a run is saved. 
4)Press the meter down and hold, lift up after the run is complete, record the DCOF when 
satisfied, either press C to repeat the run or D to save the pass. The display will ask to verify the 
SD card is in place for saving. The data will be lost if the card is not in place when starting the 
save. With the micro SD card in place, press 1 to verify and 1 again once the data is saved. The 
first of the passes takes a few seconds longer to save as the file must be set up for the number 
of passes. 
5) Follow the display prompts for the remainder of the passes. 
 
SD Card Information 
You cannot use a micro SD card that is larger than 32g capacity. If you wish to carry additional 
cards a 32g is recommended but a card of less capacity can be used. Please try any card used 
prior to field use to assure the meter is recognizing the card.  
When saving data to the card, make sure the card is in place. If it is not and you mistakenly 
press 1 to tell the device it is, the display will read that data is saving but without a card it is not. 
The meter does not have a hard storage without the micro SD card. The display will stay on 
data saving until the power is turned off. The power must be turned off and back on to move 
past this and the data from the pass will be lost.  
Once the run is saved to the card, the card can be used in any supporting device that can accept 
the card format and an Excel spreadsheet. Download the excel spreadsheet and export the data 
file to the spreadsheet for the report. If you view the DAT files, the data is encrypted so the 
numbers do not match the display when viewing and recording the DCOF number after each 
pass. 
 
Error Codes 
Meter Up Early is displayed if even down force is not applied throughout the run. The meter 
will return the sensor to the docked start position and the test will be cancelled. 
Check Motor Gear is displayed if the meter senses something that increases or decrease 
friction excessively. A grout line or unexpected contaminate may cause this. If everything looks 
ok on the test surface and the error continues there may be an internal mechanical drive issue. 
Low Battery is displayed to when the voltage drops too low to run the motor at a consistent 
speed. Replace with two 9 volt batteries. Follow all local, state and federal regulations for 
battery disposal and or recycling. Alkaline batteries are supplied. Most rechargeable batteries 
will not last as long with the constant startup of the motor. It is not recommended to use a 
lithium Ion battery. The short runs with startup loads could cause the lithium Ion batteries to 
heat up.  
 
 
 
 