DAX200/DAX400 – Installation Guide
Issue: 02 complete, approved
Page 15 of 28
Speaker Outputs 1 to 4
Signal Description
A
−
Circuit A Zone Out
−
, 100 V RMS audio
A+
Circuit A Zone Out+, 100 V RMS audio
B
−
Circuit B Zone Out
−
, 100 V RMS audio
B+
Circuit B Zone Out+, 100 V RMS audio
L
Cabling connector: 4-Way pluggable Wago male cage clamp terminal (5.08 mm)
Mains Supply
Signal Description
N
Neutral, 230 V +10,
−
6 % RMS 50 Hz AC
Protective
earth
L
Live, 230 V +10,
−
6 % RMS 50 Hz AC
DIN Rail Interlink Adaptor
The DIN rail Interlink Adaptor provides connections from the DAX amplifier system back to the DAU.
In order that the DAU can drive Expansion Amplifier Units, these units need to provide connections for the
low level audio from the DAU, the CAN bus, and the audio monitoring bus.
The low level audio, the CAN bus, and the audio monitoring bus connections are provided on a 16-way
ribbon cable connected to a box header underneath the amplifier motherboard of the DAX. By plugging this
16-way ribbon cable to the Interlink Adaptor, these connections are made available on screw-in terminals
suitable for the field cabling required to connect the DAX to the DAU.
16 14 12 10 8 6 4 2
15 13 11 9 7 5 3 1
16-WAY BOX HEADER
(To DAX 16-Way ribbon cable)
LABEL
2 x 8-WAY SCREW-IN
TERMINAL BLOCK (5 mm)
(Field Wiring – From DAU)