6.0 

REAR PANEL CONTROLS & CONNECTORS 

 

 

 

A & B LINE connectors 

These XLR-3 type connectors are for connecting 
remote stations, using standard microphone 
cable. There are 2 connectors for channel A and 
2 connectors for channel B. 
Pin assignments: 
Pin 1:  0V / ground shield 
Pin 2:  +30V DC power wire 
Pin 3:  audio wire 
 

AUX INPUT con GND lift 

This XLR-3 input is electronically balanced and 
accepts line level audio signals. Ground can be 
lifted.  

Pin assignments : 
Pin 1.  0V / ground 
Pin 2:   
Pin 3:  signal – 
  

FUSE Holder 

The fuse protects the BS 286 against severe 
internal damage, in case of malfunction in the 
power section. 

Before replacing a fuse the 

mains cord must be disconnected from the 
mains outlet. 

 

MAINS Inlet 

IEC Mains connector 

 

 7.0 

TECHNICAL SPECIFICATIONS 

 

System 

Dynamic range: 80 dB (1kHz, THD <1%) 
Frequency response: 200 Hz – 15 kHz (-3 dB) 
Call signal (send): +2.8 mA 
Call signal threshold (receive): +2.4 V DC 
Operating voltage: 24 - 32 V DC  
 

Intercom line 

Impedance: 350 Ω (1 kHz), 2.2 kΩ (DC) 
Audio level: nom. -18 dBu, max. 0 dBu 
 

Switch Mode Power Supply 

Mains voltage: 100 - 240 V AC, 50/60 Hz 
Output voltage: +30 V DC (+/- 5%) 
Max output power: 45 W 
Max power consumption: 60 watts 

 
Aux Input 

Input Impedance: 33 k

Ω 

Nominal Input Level: 0 dBu 
Max. Input Level: +22 dBu 
 

BS 287 Dimensions & Weight 

Width: 19” (483 mm) / Height: 1RU (44.5 mm) 
Depth: 140 mm / Weight: 1.5 Kg 
 

 

0 dBu defined as 775 mV rms into open circuit. 

 

ASL reserves the right to alter specifications without prior notice 

 
 
 
 
 

 
 

 

Summary of Contents for BS 287

Page 1: ...ER SUPPLY USER MANUAL May 2013 This products is designed and manufactured by ASL Intercom B V Zonnebaan 42 3542 EG Utrecht The Netherlands Tel 31 0 30 2411901 Fax 31 0 30 2667373 Email info asl inter com Web www asl inter com ...

Page 2: ... DESCRIPTION 4 3 0 MECHANICAL INSTALLATION 4 4 0 MAINS POWER SAFETY EARTH 4 5 0 FRONT PANEL CONTROLS CONNECTOR 4 6 0 REAR PANEL CONTROLS CONNECTORS 5 7 0 TECHNICAL SPECIFICATIONS 5 8 0 PARTY LINE TECHNICAL CONCEPT 6 9 0 CABLING 6 10 0 EARTHING CONCEPT 7 11 0 BS 287 BLOCK DIAGRAM 7 12 0 POSSIBLE SYSTEM CONFIGURATION 8 ...

Page 3: ...he apparatus power cord by gripping the power plug not the cord 11 Insert the plug properly Do not defeat the safety purpose of the polarized or grounding type plug An American polarized AC line plug has two blades with one wider than the other This plug will fit only one way into the power outlet This is a safety feature If you are unable to insert the plug fully into the outlet try reversing the...

Page 4: ...ides 100 240 V AC 50 60 Hz and at least 60 watts The outlet should have a clean earth Avoid using mains power outlets which also power dimmer controlled lighting equipment The wires in the mains lead are color coded green yellow Earth safety ground blue Neutral brown Live In case the wires in the mains lead do not correspond with the colored markings identifying the terminals in your mains plug pr...

Page 5: ...ion in the power section Before replacing a fuse the mains cord must be disconnected from the mains outlet 7 MAINS Inlet IEC Mains connector 7 0 TECHNICAL SPECIFICATIONS System Dynamic range 80 dB 1kHz THD 1 Frequency response 200 Hz 15 kHz 3 dB Call signal send 2 8 mA Call signal threshold receive 2 4 V DC Operating voltage 24 32 V DC Intercom line Impedance 350 Ω 1 kHz 2 2 kΩ DC Audio level nom ...

Page 6: ...cable with solid cores especially when the cable is subjected to bending during operation or installation Cable screens to XLR pin 1 The screen of each separate microphone cable and or the screen of each single pair in a multi pair cable should be connected to pin 1 of each XLR 3 connector Do not connect these screens to the metal housing of ASL units or XLR 3 wall boxes Connect metal cable trunks...

Page 7: ...PAGE 7 User Manual BS 287 May 2013 ASL Intercom BV 10 0 EARTHING CONCEPT 11 0 BS 287 BLOCK DIAGRAM ...

Page 8: ...PAGE 8 User Manual BS 287 May 2013 ASL Intercom BV 12 0 POSSIBLE SYSTEM CONFIGURATION ...

Reviews: