LEVEL SENSOR
Art.no.
80 616 64
ASKO Level sensor type 1166.
Voltage:
0,5 V output from the sensor at pressure 0 and
0-level is reached during pumping out.
Measurement by control unit.
The level sensor is mounted on the bridge for
electrical components and connected to the
PCU, see electrical diagram.
RADIO SUPPRESSION FILTER
Art.no.
80 585 58
Leakage current 230 V/ 50/60 Hz 0,3-0,4 mA
The filter eliminates radio interferences in the
machine.
INLET VALVES
3-way inlet valve
Art.no.
80 617 57
Resistance:
3,7 k
Ω
± 0,5 k
Ω
Current:
0,02 A, 5 W
Inlet valve for hot water
(option)
Art.no.
80 617 29
Resistance:
3,7 k
Ω
± 0,5 k
Ω
Current:
0,02 A, 5 W
INDICATING LAMP
(WM33A/44A)
Art.no.
80 604 78
USA
Current:
230 V, 60 Hz 1,7 mA
Art.no.
80 070 73
EU
Current:
230 V, 50 Hz 1,7 mA
DOOR LOCK
Art.no.
80 616 79
Resistance:
122
Ω
Current:
ca 2 A
The door lock is mechanical and is controlled
by the button for door opening and different
safety devices
ROTARY SELECTOR SWITCH WM33A/44A
Art.no.
80 643 62
(Programs)
Art.no.
80 64376
(Temp Speed)
FUSE
Art.no.
80 554 21
6,3 A
(EU)
80 581 40
15 A (US)
Components and measured values
Art. no. 80 800 69 Rev1