Drainage connection
The machine is supplied with a drainage hose
attached, which must be connected to a drain.
See the examples below. The height must be
600–900 mm above floor level.
The lower position (600 mm) is always preferable.
Ensure that the drainage hose has no kinks.
600-900mm
The machine can also be connected to the drain
via a spigot connection. In this case the hose
should also be 600-900 mm above the floor. The
internal diameter of the hole should be at least 18
mm.
• Cut the nipple
• Remove burrs from the hole.
See the illustration.
At least 18 mm
Electrical installation
Connect the machine by plugging it into an
earthed wall socket. The electrical wall socket
must be placed outside of the installation area to
be easily accessible.
Caution!
If this appliance is supplied from a cord
extensions set or electrical portable outlet
device, the cord extension ser or electrical
portable outlet device must be positioned so
that it is not subject to splashing or ingress of
moisture.
Connection on delivery
The machine is supplied as 1-Phase, 220-230V,
50-60Hz, heat output 2000W and has a 10A plug.
Any residual current devices must be type A.
Note!
Repairs and maintenance must be carried out
by a qualified professional.