Asko DOMESTIC TD85 Installation Instructions Manual Download Page 9

9

DRAINING THE CONDENSATE

The moisture from the laundry is extracted in the 

condenser unit and accumulated in the condensate 

tank. Condensate tank has to be emptied regularly 

(see chapter "CLEANING AND MAINTENANCE" in 

the instructions for use.)).

Interruption of the drying cycle due to full 

condensate tank can be avoided by running the 

condensate discharge hose found at the back of the 

appliance directly into a drain.

A

Remove the small short hose from the attachment 

(A).

max 1000 mm 

max 39.4"

max 300 mm 

max 300 mm 

max 11.8"

max 11.8"

B

C

D

Connect the supplied drain hose to the same 

attachment (A). The supplied drain hose has a 

length of 78 3/4" (2000 mm).

Run the condensate drain hose into a drain. Tie the 

hose onto a tap (B) so that it cannot slip during use. 

The drain hose can also be fed into the washbasin 

siphon (C) or directly into the 

fl

 oor drain (D).

Then, the water is pumped directly into a washbasin, 

a siphon, or a 

fl

 oor drain.

  Do not pull the drain hose, and make sure it is 

not under tension, clamped, or bent.

  If you decide to run the condensate drain hose 

into a drain, siphon, or washbasin, make sure the 

hose is securely fastened. This will prevent any 

water spillage which could result in unexpected 

damage.

  Always use hoses that are supplied with the 

appliance.

  If the dryer is connected to an air exhaust 

system already used for another appliance, a non-

return valve must be installed. Return 

fl

 ow into the 

dryer could damage the appliance and the non-

return valve prevents such 

fl

 ow.

TRANSPORT/WINTER STORAGE

The machine must be transported upright!

Leave the machine to stand upright for 24 hours after 

transporting. If you need to move your machine or 

store it over the winter in unheated premises, make 

sure that you drain the condensed water container 

beforehand.

Summary of Contents for DOMESTIC TD85

Page 1: ...INSTALLATION INSTRUCTIONS TD85 Carefully read the instructions for use before using the dryer Heat pump Tumble Dryer DOMESTIC...

Page 2: ...operate correctly at such low temperatures or may freeze which can result in damage to the machine Install the dryer in a room with adequate ventilation and a temperature between 10 C 50 F and 25 C 7...

Page 3: ...yer feet and the floor is not su cient the dryer may move during operation To prevent sliding use a non slide mat or install the supplied vacuum feet onto both front feet Place the dryer so that it is...

Page 4: ...part B is designed to fit on ASKO washing machines and it may be hard or impossible to mount on appliances of other brands If the washing machine and dryer are not of matching dimensions or if you ha...

Page 5: ...panner The feet allow levelling by 1 cm 0 39 2 After adjusting the height of the feet firmly tighten the jam nuts using a spanner No 17 0 67 by turning them towards the bottom of the washing machine 3...

Page 6: ...1Open the door fully 2Undo the screws and remove the door 3Use the screwdriver to remove the door lock cover and undo the screw on the door lock 4Push the door lock upwards and remove it Move it to th...

Page 7: ...ly to the left hand side Use the screwdriver to remove the plastic part more easily 7Undo the door ring and remove it temporarily 8Rotate the door glass cover by 90 so that the sign indicating the ope...

Page 8: ...facing Creating ventilation gaps in the kitchen unit When build under drying times may be longer The dryer should not be installed next to a refrigeration appliance The warm air expelled from the rea...

Page 9: ...ed into the washbasin siphon C or directly into the floor drain D Then the water is pumped directly into a washbasin a siphon or a floor drain Do not pull the drain hose and make sure it is not under...

Page 10: ...ll be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited Grounding through the neutral conductor is prohibited for new branch circuit instal...

Page 11: ...power supply cord with four No 10 copper wires and a matching 4 wire receptacle of NEMA Type 14 30R as illustrated below The fourth wire must be identified with a white cover and the ground conductor...

Page 12: ...We reserve the right to modifications TD85 SPHP DOM US CA en 12 21 US ASKO COM CA ASKO COM ASKO COM MX...

Reviews: