9. Performance Evaluation
Since we need to test the minimum DC cycle time, we use beckhoff's IPC as the master.
Test environment:
Beckhoff C69200-0050
, please refer to:
en/products/ipc/pcs/c69xx-compact-industrial-pcs/c6920.html
9-1 Minimum DC Cycle Time
With TwinCAT Master, the DC and PD conditions are shown as below. Master use LRW command to do PD
transfer with 8bytes input and 8bytes output, under this setting, the minimum DC cycle time can down to
250us.
Figure 9 - 1
Without frame lost and Tx/Rx error at Master side.
Figure 9 - 2