background image

General safety information:

Installation

Installation Kit Included (find in carton)

2

-- N

OTE: Do not install dryer over washbasin  

--

Operating Instructions and Parts Manual 

Hand Dryer

                                Disconnect power at the
service breaker before installing or servicing. 

                                This product is intended 
for installation by a qualified service person. 
Use AWG NO. 12 solid conductor for wiring.

                                All units must be supplied 
with a 3-wire service. The ground wire must 
be connected to the dryer's backplate. 

                                Failure to properly ground 
unit could result in severe electrical shock 
and/or death.

www.americanspecialties.com

1. Make sure power supply breaker is switched off. Installation must be carried out in accordance 
    with the current edition of the local wiring regulations code having jurisdiction. Installation should 
    be performed only by a qualified electrician.
2. Place template against wall at desired height (see mounting height recommendations) and mark 
    locations of 4 mounting holes and wire service entry at knockout (KO) location.
    

Note: 

For two or more dryers,  dryers should be no closer than 24 inches (610 mm) on center.  

3. Remove and retain 2 cover screws and cover.
4. 

For in-wall (concealed) power supply - 

Provide supply wire to KO location according to local code 

    and attach securely to chassis at KO with appropriate strain relief connector (not supplied).
5. Attach dryer to wall. For wood wall/studs use 

¯

1/4 inch (M6) screws at length that will ensure 

   1 inch (25 mm) min. stud penetration. For masonry walls use expansion bolts or anchors for 

¯

1/4 inch 

   (M6) screws  to ensure penetration 1/4 inch (6 mm) deeper than anchor. Shim if necessary to 
   ensure base plate is flat against wall.
6. Connect supply and ground wires to terminal block where indicated or connect supply wires to terminal 
   block where indicated and connect ground wire to base plate with ground screw (Connections: A. 
   Connect the live wire (colored Brown or Black) to the terminal block marked "L1". B. Connect the 
   neutral wire (colored White or Grey) or connect the second live wire (colored Red or Orange) to the 
   terminal block marked "N/L2". C. Connect the ground wire (colored green or green and yellow or bare 
   conductor) to the terminal block marked "    " or to the green screw marked "    "). Colors of live and 
   neutral wires depend on voltage of supply service and requirements of Building and Electrical Code 
   having  jurisdiction.
7. Replace cover. Do not over-tighten screws. 

 

 

1. Self-Threading screws 1/4" x 2-1/2" (M6 x 64) x 4 pcs
2. Security hex wrench 5/32" (4) L-Type x 1 pcs

06092857

Surface-mounted Automatic hand dryer 