ASI JD MACDONALD AUTOBEAM Operating Instructions And Parts Manual Download Page 4

4

Operating Instructions and Parts Manual 

Hand Dryer

Symptom                                                                 

Corrective Action 

Troubleshooting

If the dryer will not run

First ensure that the breaker supplying the dryer is operational.
If it is, disconnect the power and remove the dryer cover.
Check for obstructions blocking the rotation of the blower and
clear any found. If it spins freely, check the motor and 
thermostat for proper operation out of the unit. Replace any
failed items. Taking suitable precautions to avoid shock hazard, 
reconnect the power and check for voltage at the terminal 
block. If there is power and the dryer will not run, replace the 
timer assembly and/or sensor module.

If the dryer cycles by itself, or runs
all the time, or shuts off by itself
while in mid-cycle

If the element gets hot but the fan 
motor does not turn

Disconnect the power. Remove the dryer cover and check for 
obstructions in the fan housing. Damaged fans must be 
replaced. If there are no obstructions, replace the motor.

If the fan motor runs but the element 
does not get hot 

(Dryer blows cold air)

Disconnect the power and remove the dryer cover. Check for 
loose or damaged wires. Remove the blower housing. 
Check the element for signs of burning or breakage. Damaged 
element must be replaced. If the element does not appear 
damaged, disconnect it at the timer assembly and check 
element wire continuity (see tech spec). An open circuit 
indicates damage to the element wire and to the integral 
temperature limit control (TLC). Separate the TLC and test for 
open circuit. If this is the case, replace the element and/or the 
thermostat.

If the motor makes ticking/winding 
noise when it runs

If the unit runs but makes a
buzz noise

Disconnect the power. Remove the dryer cover and check the 
fan for obstructions and/or rubbing on the housing as it 
rotates. Remove any obstructions and replace fan if the 
rubbing condition exists.

Ensure that there is no obstruction on or in front of the 
infrared sensor. Clean any dirt off the sensor lens. Check for
voltage spikes on power line. If the problem persists, replace 
the timer assembly and/or the sensor module.

Disconnect the power. Remove the dryer cover and check the 
brushes for worn condition (less than 25/64" (10mm) graphite 
remains) and  replace them, if necessary. Purchase rebuild 
kit to perform repair.

Surface-mounted Automatic hand dryer 

www.asijdmacdonald.com.au  

1800 023 441  

www.asijdmacdonald.com.au

A S I J D M a c D o n a l d P t y. L t d .

Summary of Contents for AUTOBEAM

Page 1: ...7 0kg 15 4lbs 300mm W x 251mm H x 219mm D 11 13 16 x 9 7 8 x 8 5 8 2200W 220 240VAC nichrome 27 2Ω 100mm to 250mm 4 to 10 adjustable standard 170mm 20mm 7 www asijdmacdonald com au Auto resetting thermostat turns unit off at 65 C 149 F resets at 50 C 122 F HDABWHTSG white with silver gloss nozzle HDABWHTPC white with polished chrome nozzle HDABPSSPC polished stainless steel with polished chrome no...

Page 2: ...rely to chassis at KO with appropriate strain relief connector not supplied 5 Attach dryer to wall For wood wall studs use 1 4 inch M6 screws at length that will ensure 1 inch 25 mm min stud penetration For masonry walls use expansion bolts or anchors for 1 4 inch M6 screws to ensure penetration 1 4 inch 6 mm deeper than anchor Shim if necessary to ensure base plate is flat against wall 6 Connect ...

Page 3: ...dren 4 7 years Children 8 10 years Children 11 13 years Children 14 16 years 50 1194 mm 47 889 mm 35 991 mm 39 1092 mm 43 1194 mm 47 Surface mounted Automatic hand dryer Circuit Diagram www asijdmacdonald com au 1800 023 441 www asijdmacdonald com au Circuit Board Module MO2 HE2 N MO1 HE1 L Transistor Power Switch G N L Thermostat G Y Blue Brown Motor With Thermal Switch 2A Black 120 240V Black 12...

Page 4: ...oose or damaged wires Remove the blower housing Check the element for signs of burning or breakage Damaged element must be replaced If the element does not appear damaged disconnect it at the timer assembly and check element wire continuity see tech spec An open circuit indicates damage to the element wire and to the integral temperature limit control TLC Separate the TLC and test for open circuit...

Page 5: ...housing RH Thermostat TLC Motor bracket Nylon washer Motor Motor 200W 240Vac Motor brush Rubber grommet Motor Rating label 220 240Vac Terminal label Screw M4x6 headless set with 2mm hex key Screw 10 24x1 2 philips truss head Hex Nut 10 24 Self Threading Screw M4x10 philips pan head 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 A0183 A0131 A0065 A0066 A0068 A0069 A0071 A0072 A0277 A0288 Screw M5x10 ...

Page 6: ...urface mounted Automatic hand dryer 1 2 3 4 5 Assembly Diagram www asijdmacdonald com au 1800 023 441 www asijdmacdonald com au 6 7 8 9 11 12 23 34 13 14 15 16 17 18 19 20 21 22 36 24 25 26 27 28 29 31 32 33 35 37 38 39 40 41 42 10 ASI JD MacDonald Pty Ltd ...

Reviews: