Operating Manual - nX, nXe, and nXp 150W/75W Power Amplifiers
50
CobraNet Receiver Control
Bundle
: Selected bundle this receiver is listening to.
Status
: Indicates if a valid (green) bundle is being received.
Channel Status (1-8)
: The signal status indicates the current bit depth, sampling rate, and latency of the received audio
stream. The LED indicates this is a valid stream for this device.
The sampling rate and latency of the transmitting device must
match that of the receiver.
CN Matrix:
The CobraNet matrix allows the user to route any of the channels being received to the desired amplifier
inputs channels.
Input Source Selection:
The user can select the input source type for each amplifier channel. For CobraNet, the selec
-
tion must be either [Network with Analog Backup] or [Auto]. When Analog Backup is engaged the device will switch to analog
when there is no valid CobraNet data being received.
13.1a CobraNet Configuration Tab
A CobraNet Interface has several parameters that may need to be configured for proper operation. The "CobraNet Config" screen
presents many of these networking controls as well as feedback as to the status of the CobraNet interface. It is also possible to
view and modify these parameters via
CobraNet Discovery
.
General Configuration
Description
: Description of the unit and its firmware.
Location
: User-definable string typically indicating the
location of the CobraNet device.
Contact
: User-definable string typically indicating the con
-
tact person for the CobraNet device.
Conductor Priority
: The higher the priority the more likely
it is this unit will become the "Conductor". The conductor
is the master clock and all other clocks are synchronized to
this clock.
Conductor/ Performer
: Indicates if the unit is currently the
conductor or a performer. There can be only one conductor
on a CobraNet network.
Audio Mode
: Sampling rate and latency for the device.
Both sending and receiving units must be configured for the
same audio mode.
Audio Mode Status
: The current audio mode of the unit. If a mode is not supported this status may not equal the selected mode.
CobraNet Network Configuration
MAC Address
: The unique MAC address for the CobraNet
interface. Note there is a separate MAC address
for the control-only interface. Both primary and secondary ports share the same MAC address.
IP Address
: The current IP address for the CobraNet interface.
Static IP Address
: When set to an addressable IP address (not 0.0.0.0) this is the IP address used by the
CobraNet device on the CobraNet ports. When this is 0.0.0.0, auto configuration is used by the
CobraNet
device to obtain an IP address. This IP address can be provided by either BOOTP/DHCP or
CobraNet Discovery (which uses RARP).