4.0 Technical specifications
This chapter discusses the following topics:
l
l
l
l
4.1 Wiring
Choose the appropriate size of the wire based on the distance from the amplifier to the speaker:
Distance
Wire Size
Up to 25 ft (7.6 m)
16 AWG
26–40 ft (7.9–12.2 m)
14 AWG
41–60 ft (12.5–18.3 m)
12 AWG
Over 60 ft (18.3 m)
10 AWG
Table 2: Wiring distance and size
Caution
: Do not connect the speaker return to the amplifier's chassis, or damage to the amp-
lifier may result. Do not use shielded cable for output wiring.
4.2 Minimum guaranteed power
The Ashly Power Amplifier guarantees the following minimum power:
l
150 W per channel at 8 ohms
l
250 W per channel at 4 ohms
4.3 Reliability
The Ashly Power Amplifier's (P/N: ne8250c low-Z) typical mean time between failure (MBTF)
is 478,000 hours.
8
Copyright © 2019 Advanced Simulation Technology inc.