ne4250.70

 

- Four Channels, 70 volt output, 250W per channel

ne8250.70

 

- Eight Channels, 70 volt output, 250W per channel

ne4250.10

 

- Four Channels, 100 volt output, 250W per channel

ne8250.10

 

- Eight Channels, 100 volt output, 250W per channel

The basic NE multichannel amplifiers come in either four channel or eight channel configurations with

 

Euroblock

input connectors.  Output connectors are also Euroblock.  Standard features on all models include balanced analog

inputs, bridge mono mode per channel pair, full ethernet control using 

Protea

ne 

software, remote standby for power up,

contact closure preset recall, remote control through micropocessor based devices such as the Ashly WR-5, RD-8C, or

other custom control, and DC remote level control using an Ashly WR-1.

Additional hardware options for the 

NE

 

multichannel power amplifiers include the following:

1)  Internal DSP Processing

 - With this factory installed option, and using 

Protea

ne 

(network enabled) software,

each amplifier input channel can be configured with pluggable DSP blocks to have its own dynamics control, gain

functions, graphic and/or parametric EQ, Hi-pass/Lo-pass filters, time delay, metering, and test signal generator.  A

mixer section with assignable routing allows any input to drive any or all amplifier outputs.  Outputs have the same DSP

functions as inputs, with the addition of a fast, automated crossover setup.  Both inputs and outputs can copy/paste their

settings to other channels, or can link with one or more other channels to track their settings.

Presets can be used to store and retrieve global parameters of an entire amplifier’s control surface and DSP section

from a file.  In addition, Sub Presets allow for a collection of individual DSP function parameters within and across

multiple channels of an amplifier to be stored and recalled as a set, affecting only those parameters and channels which

have been tagged.  Up to 35 presets/subpresets can be stored within the amplifier, and can be recalled in real time from

a computer, WR-5 remote control, or contact closure switches (up to four).

2)  AES/EBU Input

 - Using an optional four or eight channel input card, NE

 

multichannel amplifiers can accept AES/

EBU digital inputs.  This protocol allows 2 channels of digital audio to be transmitted over a single cable, thus maintaining a

completely digital signal path until just before the power amplification stage. 48kHz & 96kHz data rates are supported.

3)    MIC  Inputs

  - In conjunction with the factory installed DSP option, four analog MIC inputs can be installed

(instead of AES/EBU) for full gain, mixing, and dsp processing capabilities using 

Protea

ne 

software.

4)  Network Digital Audio (Cobranet)

 - This option allows the NE multichannel amplifier to be part of a net-

worked audio distribution system.  CobraNet is a technology developed and supported by Cirrus Logic (

www.cirrus.com

).

It is a combination of software, hardware and network protocol which allows distribution of multiple channels of real-

time, high quality digital audio over a standard Ethernet Network.  For detailed information about CobraNet or its

implementation or installation please visit 

www.cobranet.info

.

Protection

Ashly 

NE

 multichannel amplifiers come standard with several protection circuits:

Over Current Protection

 - Is controlled in the output stage.

Thermal Protection 

- When the internal temperature is below 40°C the fan runs at its slowest speed. Above 40°C

the speed is increased until it reaches its maximum value. If the temperature exceeds 100°C, the input on that channel is

reduced. If the temperature exceeds 120°C, the power supply is switched off.

Mains Protections 

– protection within the power supply includes: Inrush Current Limitation during power up,

Mains Over Voltage Detection, and internal Mains Fuse Protection.  To protect the Mains fuse against AC overcurrent

due to excessive audio output current, there is a protection scheme controlled in 

Protea

ne 

software and indicated on the

amplifier front panel which reduces audio output level until the overcurrent condition is no longer present.

Summary of Contents for ne 4200.10

Page 1: ...er NY 14580 9103 Phone 585 872 0010 Toll Free 800 828 6308 Fax 585 872 0739 www ashly com ne 4250 ne 8250 ne 4250 25 ne 8250 25 ne 4250 70 ne 8250 70 ne 4250 10 ne 8250 10 Network Enabled Multi Channe...

Page 2: ...6 Front Panel Features 6 Rear Panel Features 7 Installation Requirements 7 Constant Voltage Models 25V 70V and 100V and High Pass Filters 7 4 REMOTE CONTROL 8 On Off Remote Standby 8 Preset Recall 8...

Page 3: ...OVE COVER NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL TO REDUCE THE RISK OF FIRE OR ELECTRICAL SHOCK DO NOT EXPOSE THIS APPlIANCE TO RAIN OR MOISTURE TO REDUCE THE...

Page 4: ...ustomer FCC Compliance This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accep...

Page 5: ...to 35 presets subpresets can be stored within the amplifier and can be recalled in real time from a computer WR 5 remote control or contact closure switches up to four 2 AES EBU Input Using an option...

Page 6: ...tput voltage is 1 2 volt below the output power supply voltage 7 Bridge This LED indicates that the channel pair is selected to BRIDGE mode from the back panel switch and that only the odd input chann...

Page 7: ...UTION When mounting or connecting the amplifier always disconnect it from the mains Use four screws and washers when mounting the amplifier to the front rack rails Rear support is also recommended esp...

Page 8: ...isabled from software the front panel DISABLE LED will light The power switch will remain inactive until enabled again from software even if the amp is removed from power Preset Recall The four contac...

Page 9: ...or visit the Ashly web site at www ashly com for more WR 5 details RD 8C or RW 8C Remote Control A second microprocessor based controller the Ashly RD 8C is an eight channel wall mount level controll...

Page 10: ...vices are networked Linking of multiple devices is managed through LINK GROUPS Each Proteane device will support up to eight Link Groups DSP function blocks may be assigned to these groups though Prot...

Page 11: ...ials indicate the physical position of hardware controls on either the amp front panel or the remote level control if present Note that these will display the position of attenuators even when DISABLE...

Page 12: ...elp Menu Contents and Index Contents Protea NE Products PE Multichannel Amplifiers DSP Control for details of all DSP func tions The key features include 1 Input Channel Number Right click on this to...

Page 13: ...Hz 20kHz 1 THD 150W 4 ohms 20Hz 20kHz 1 THD 250W Bridge Mode 8 ohms 20Hz 20kHz 1 THD 500W 25 70 100 Volt models 20Hz 20kHz 1 THD per channel 250W Signal to Noise 20Hz 20KHz unweighted 98dB Power Requi...

Page 14: ...ain Gain off 50dB to 12dB Gain w VCA off 50dB to 12dB WR 5 Remote Gain off 50dB to 12dB Equalization 31 Band Graphic Filter Type constant Q or proportional Bandwidth 0 499oct to 0 25oct 2 4 6 or 10 Ba...

Page 15: ...l Audio Input Type 110 ohm transformer balanced XLR Sample Rates 48kHz 96kHz Max Cable Length 100 meters 7 WARRANTY INFORMATION The unit you have just purchased is protected by a limited five year war...

Page 16: ...annel Power Amplifiers ASHLY AUDIO INC 847 Holt Road Webster NY 14580 Phone 585 872 0010 Fax 585 872 0739 Toll Free 800 828 6308 www ashly com 2008 by Ashly Audio Corporation All rights reserved world...