background image

KLR-2000

The two-channel power amplifier shall incorporate the latest amplifier technology to deliver a minimum power of 1,000 Watts per channel into 2 Ohm loads, 600 Watts 

RMS per channel into 4 Ohm loads, or 350 Watts RMS per channel into 8 Ohm loads with both channels operating. The amplifier shall have rear panel switching for parallel 

mono and bridging modes. When switched into bridged-mono mode, the amplifier shall deliver 2,000 Watts into a 4 Ohm load. The amplifier protection shall include 

output over-current, DC output, chassis temperature, and a mains circuit-breaker. Frequency response shall be 20Hz–20kHz (1W @ 8 Ohms). The Signal-to-Noise Ratio shall 

be greater than 108dB at rated power into 8 Ohms (unweighted). THD shall be less than 0.05% into 4 Ohms, 20Hz–20kHz and 10dB below rated power. The amplifier shall 

have a channel attenuator for each input on the front panel and input sensitivity select switch, a high-pass filter switch and limiter enable switch on the rear panel. The 

inputs shall be of balanced bridging type with XLR, ¼” TRS, and 3-pin Euroblock connectors. The outputs shall be four pin SpeakON type connectors. LED type indicators 

shall be employed to show the relative power level of each channel, clip/protect and power on/off. Self contained forced air cooling (front in) shall be used with front panel 

mounted, removable dust filters. The power amplifier shall weigh 26.2lbs/11.9kg net and mount in a standard 19 inch rack using two spaces (3.5 inches high). The power 

requirement shall be 120VAC or 240VAC ±10%, 50–60Hz, factory set. 

The power amplifier shall be the Ashly KLR-2000.

KLR-3200

The two-channel power amplifier shall incorporate the latest amplifier technology to deliver a minimum power of 1,600 Watts per channel into 2 Ohm loads, 1,100 Watts 

RMS per channel into 4 Ohm loads, or 650 Watts RMS per channel into 8 Ohm loads with both channels operating. The amplifier shall have rear panel switching for parallel 

mono and bridging modes. When switched into bridged-mono mode, the amplifier shall deliver 3,200 Watts into a 4 Ohm load. The amplifier protection shall include 

output over-current, DC output, chassis temperature, and a mains circuit-breaker. Frequency response shall be 20Hz–20kHz (1W @ 8 Ohms). The Signal-to-Noise Ratio shall 

be greater than 109dB at rated power into 8 Ohms (unweighted). THD shall be less than 0.05% into 4 Ohms, 20Hz–20kHz and 10dB below rated power. The amplifier shall 

have a channel attenuator for each input on the front panel and input sensitivity select switch, a high-pass filter switch and limiter enable switch on the rear panel. The 

inputs shall be of balanced bridging type with XLR, ¼” TRS, and 3-pin Euroblock connectors. The outputs shall be four pin SpeakON type connectors. LED type indicators 

shall be employed to show the relative power level of each channel, clip/protect and power on/off. Self contained forced air cooling (front in) shall be used with front panel 

mounted, removable dust filters. The power amplifier shall weigh 26.4lbs/12kg net and mount in a standard 19 inch rack using two spaces (3.5 inches high). The power 

requirement shall be 120VAC or 240VAC ±10%, 50–60Hz, factory set. 

The power amplifier shall be the Ashly KLR-3200.

KLR-4000

The two-channel power amplifier shall incorporate the latest amplifier technology to deliver a minimum power of 2,000 Watts per channel into 2 Ohm loads, 1,400 Watts 

RMS per channel into 4 Ohm loads, or 850 Watts RMS per channel into 8 Ohm loads with both channels operating. The amplifier shall have rear panel switching for parallel 

mono and bridging modes. When switched into bridged-mono mode, the amplifier shall deliver 4,000 Watts into a 4 Ohm load. The amplifier protection shall include 

output over-current, DC output, chassis temperature, and a mains circuit-breaker. Frequency response shall be 20Hz–20kHz (1W @ 8 Ohms). The Signal-to-Noise Ratio shall 

be greater than 109dB at rated power into 8 Ohms (unweighted). THD shall be less than 0.05% into 4 Ohms, 20Hz–20kHz and 10dB below rated power. The amplifier shall 

have a channel attenuator for each input on the front panel and input sensitivity select switch, a high-pass filter switch and limiter enable switch on the rear panel. The 

inputs shall be of balanced bridging type with XLR, ¼” TRS, and 3-pin Euroblock connectors. The outputs shall be four pin SpeakON type connectors. LED type indicators 

shall be employed to show the relative power level of each channel, clip/protect and power on/off. Self contained forced air cooling (front in) shall be used with front panel 

mounted, removable dust filters. The power amplifier shall weigh 26.7lbs/12.1kg net and mount in a standard 19 inch rack using two spaces (3.5 inches high). The power 

requirement shall be 120VAC or 240VAC ±10%, 50–60Hz, factory set. 

The power amplifier shall be the Ashly KLR-4000.

KLR-5000

The two-channel power amplifier shall incorporate the latest amplifier technology to deliver a minimum power of 2,500 Watts per channel into 2 Ohm loads, 1,700 Watts 

RMS per channel into 4 Ohm loads, or 1,000 Watts RMS per channel into 8 Ohm loads with both channels operating. The amplifier shall have rear panel switching for par-

allel mono and bridging modes. When switched into bridged-mono mode, the amplifier shall deliver 5,000 Watts into a 4 Ohm load. The amplifier protection shall include 

output over-current, DC output, chassis temperature, and an internal mains fuse. Frequency response shall be 20Hz–20kHz (1W @ 8 Ohms). The Signal-to-Noise Ratio shall 

be greater than 110dB at rated power into 8 Ohms (unweighted). THD shall be less than 0.05% into 4 Ohms, 20Hz–20kHz and 10dB below rated power. The amplifier shall 

have a channel attenuator for each input on the front panel and input sensitivity select switch, a high-pass filter switch and limiter enable switch on the rear panel. The 

inputs shall be of balanced bridging type with XLR, ¼” TRS, and 3-pin Euroblock connectors. The outputs shall be four pin SpeakON type connectors. L.E.D type indicators 

shall be employed to show the relative power level of each channel, clip/protect and power on/off. Self contained forced air cooling (front in) shall be used with front panel 

mounted, removable dust filters. The power amplifier shall weigh 28.2lbs/12.8kg net and mount in a standard 19 inch rack using two spaces (3.5 inches high). The power 

requirement shall be 120VAC or 240VAC ±10%, 50–60Hz, factory set. 

The power amplifier shall be the Ashly KLR-5000.

KLR SERIES 

a

rChiTeCT

 & e

ngineering

 s

PeCs

Reviews: