Ashly CLX-52 Operating Manual Download Page 7

Operator Manual – CLX-52 Compressor/Limiter

Page - 7

All Rights Reserved

CLX-52 Rear Panel

1.

 

Inputs and Outputs - 

Your CLX

Compressor/Limiter is provided with three
different connector types. 1/4" TRS (tip-ring-
sleeve) jacks, XLR connectors and Euroblocks.
Inputs are 20K

 active balanced using 1%

metal film resistors, outputs are 132

 servo-

balanced.

2.

 

Detector Loop – Ducking - 

The CLX

Compressor/Limiters have a TRS Insert
DETECTOR PATCH point which can be used
as a "ducking" input, or in conjunction with an
equalizer to produce frequency-sensitive
limiting. Various uses of the detector patch are
discussed under Typical Applications.

3.

 

Power – 

Switches the unit power on or off.

Installation

Use four screws and washers when rack mounting the unit.  For mobile use, the unit should
be further secured as appropriate.

General Requirements

The CLX-52 has specific physical, electrical and signal requirements for proper operation.
These requirements will vary depending on your specific application, setup, and the
settings on the unit.  When setting up and testing your system, please take special care to
double check all connections and settings.  Please refer to the specifications section of this
manual for specific input, output and other figures.

AC Power

Your CLX-52 equalizer should be connected to a standard 3-wire grounded electrical
outlet supplying 100-240 Volts, 50-60 Hz. To reduce the risk of ground loop hum, connect
all audio equipment to the same electrical power source. Removal of the ground pin is both
unlawful and dangerous, as a potential shock hazard could result.

This unit will perform normally within the AC voltage range specified above. Voltages
less than this, as found in “brown-out” conditions, may reduce performance. In the event of
a blown fuse, replace only with same type fuse. No user serviceable parts are inside the
chassis. Overall power consumption is less than 5 watts.

NOTE

: The power switch does NOT isolate the appliance from mains. Make sure the mains

power socket or an alternative disconnect device is near by and easily accessible. When the
product is connected to mains, the line-filter and the input of the fuse are energized.

Safety Instructions – 3

Introduction - 4

CLX-52 – 5

Connectors & Cables – 5

Physical Description - 6

Front Panel

Rear Panel

Installation – 7

General Requirements

AC Power

Typical Applications - 8

Troubleshooting - 9

Dimensions - 9

Specifications - 10

Warranty - 11

Summary of Contents for CLX-52

Page 1: ...imiter Operating Manual Ashly Audio Inc 847 Holt Road Webster NY 14580 9103 Toll Free 800 828 6308 Telephone 585 872 0010 FAX 585 872 0739 www ashly com All Trademarks referred to herein are the prope...

Page 2: ...Page 2 Operator Manual CLX 52 Compressor Limiter Copyright 2006 Ashly Audio Inc This page intentionally left blank...

Page 3: ...s consignes du fabricant 9 Eloigner des sources de chaleur tel radiateurs fourneaux ou autres appareils qui produisent de la chaleur 10 Ne pas modifier ou amputer le syst me de la mise terre Une prise...

Page 4: ...committed to these principles What Compressors And Limiters Do Limiting All musical programs have constant changes in loudness It is the job of a limiter to detect when the volume has exceeded a prede...

Page 5: ...CLX 52 Compressor Limiter is provided with three different connector types 1 1 4 inch stereo phone jacks TRS 2 Three pin XLR type connectors 3 Euroblock Connector When possible balanced connections a...

Page 6: ...position all limiting and compression controls and functions are bypassed with the exception of the Gain and Output controls which continue to function 8 Stereo Tie Switch This switch allows for Gain...

Page 7: ...eck all connections and settings Please refer to the specifications section of this manual for specific input output and other figures AC Power Your CLX 52 equalizer should be connected to a standard...

Page 8: ...r can be used to prevent input overload clipping distortion in a live recording environment To prevent distortion while preserving dynamic range set the CLX 52 as follows Gain 0 Threshold 2 3 dB below...

Page 9: ...volume by a proportionate amount This is not a defect in the Compressor Limiter but an unavoidable side effect of the gain altering process If the noise becomes a problem the solutions are to either...

Page 10: ...20 K balanced Output Impedance 132 servo balanced Frequency Response 20 Hz 20 kHz 0 2 dB Distortion 01 THD 0dBu 1KHz 0 15 THD 15dBu 20Hz 20KHz Output Hum Noise 96dBu Power Requirements 100 240 Volts 5...

Page 11: ...duct Ashly Audio shall be liable only to correct defects in the product itself and not for any damage or injury which may result from or be incidental to or a consequence of such defect Some states do...

Page 12: ...Copyright 2006 Ashly Audio Inc...