background image

11

Operating Manual - PROTEA SYSTEM II  3.24CL Crossover / System Processor

4.7d  Mute

The Protea 3.24CL allows the user to mute both inputs and outputs.  When muted, an input or output's red Mute

LED is lit.  When an input or output is selected, pressing the Mute button will toggle its mute function.  To quickly mute

all outputs, escape out to the top level preset display, then press the Mute button, pressing it a second time to confirm.

Additionally, when recalling a new preset number to the 3.24CL, the LCD display prompts the user to mute all outputs, as

a new preset can introduce dramatic changes to the system configuration.

4.7e  Util

The Protea 3.24CL utilities in-

clude a security section for password

protected lockout, and a dBu/VU meter

preference select.

Security

There are four security modes in the 3.24CL. Off (default), Preset Lock, Parameter Lock, and Full Lockout offer

varying degrees of protection to the 3.24CL system.

1.)  Off (none)  allows full access to all controls.

2.)  Preset Lock allows full access while disabling the save function.

3.)  Parameter Lock allows the user to recall different presets, but allows no changes other than mute.

4.)  Full Lockout allows absolutely no local changes, but allows viewing of current settings.

To access the security menu, first press the Util button, then select the Security display line on the LCD.  Use the

data wheel to select from the four security levels.  If the unit is brand new and has never had a security code, or has had

a factory reset, a four digit code must first be entered before changing security status.  Use the output select buttons 1-

6 (recommended) or  the data wheel (0-9) to enter a new code, then press Enter on the LCD.  The LCD then prompts the user

to either change the code to a new four digit number, or change the Security status to one of the other three options.

The only way to fully remove a security code once it has been entered is with a factory reset.  This is done by

turning the power on while pressing Esc and Recall together, returning all settings, 

including user defined presets,

 to

their original factory settings.  

Note:  In the event the four digit security code is forgotten, turn the 3.24CL on while

pressing both the Esc and Util buttons.

dBu/VU Meter Select

The input and output meter scale is factory set so that a green LED flashing at 0 indicates a signal level of 0dBu,

or 0.775Vrms.  To change this to a VU scale, where 0VU = +4dBu (1.228Vrms), select the <Ref:> option in the Util menu to

VU.

4.7f  Factory Reset

To clear all preset names, reset all controls to their original factory settings, and delete the password from

memory, Factory Reset may be performed by 

simultaneously pressing and holding Esc and Recall

 while switching power

on.  

Caution:  doing this will erase all user-defined presets!

Summary of Contents for 3.24CL-d

Page 1: ...DIO INC 847 Holt Road Webster NY 14580 9103 Phone 585 872 0010 Toll Free 800 828 6308 Fax 585 872 0739 www ashly com 3 24CL 3 24CL d Digital Crossover System Processor Operating Manual Digital Audio P...

Page 2: ...ANEL CONTROL FEATURES 5 4 1 Function Keys and Data Wheel 5 4 2 Presets 5 4 3 Input Select 5 4 4 Output Select 5 4 5 LED Indicators 5 4 6 Audio Functions 6 4 6a Gain 6 4 6b EQ 6 4 6c Delay 7 4 6d Cross...

Page 3: ...within an equilateral triangle is in tended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk...

Page 4: ...functions and system tools The display indicates the current preset number then subse quently shows the selected input or output and its active control parameters Five segment LED arrays on each inpu...

Page 5: ...settings should the unit be turned off before changes can be saved When the 3 24CL is first powered up the last working preset is loaded displaying the number and name last used before the unit was tu...

Page 6: ...annel has four selectable EQ filters In all cases each filter is se lectable between parametric PEQ 1st order Low Shelf LS1 2nd order Low Shelf LS2 1st order High Shelf HS1 and 2nd order High Shelf HS...

Page 7: ...ble the filter action will be Finding the problem frequency is relatively easy but finding the best combination of cut and bandwidth takes a little practice Again it is well worth the time becoming co...

Page 8: ...Lnkwtz 4 6d Crossover Xover Crossover functions on the Protea 3 24CL are available only on the six output channels Every channel s crossover consists of a high pass filter HPF and a low pass filter L...

Page 9: ...e reason for this is that Linkwitz Riley filters are defined in terms of performance criterion on the summing of two adjacent crossover HPF and LPF filters rather than defined in terms of the pole zer...

Page 10: ...he recall button once select the desired preset number and press recall again At this point the LCD display prompts the user to mute the outputs or not and selecting Yes or No will load the new preset...

Page 11: ...button then select the Security display line on the LCD Use the data wheel to select from the four security levels If the unit is brand new and has never had a security code or has had a factory reset...

Page 12: ...bleshooting Tips No power Is the detachable AC cord fully plugged in Is the rear panel power switch on Controls don t work check the Security Level If set to Full Lockout then Protea unit is view only...

Page 13: ...put Delay 0 85 milliseconds Output Delay 0 256 milliseconds Crossover HPF and LPF Frequency Range 19 7Hz to 21 9kHz Off Available Filter Types 12dB Oct Butterworth 12dB Oct Bessel 12dB Oct Linkwitz Ri...

Page 14: ...EQ Filter no 3 Filter Type _____________ Frequency _________ Boost Cut _______ Bandwidth PEQ ________ EQ Filter no 4 Filter Type _____________ Frequency _________ Boost Cut _______ Bandwidth PEQ ____...

Page 15: ...__________________ Attack Time ________________ Release Time ____________________ Output 4 Source ______________ Output Gain ____________ Polarity ___________ Output Delay ____________________________...

Page 16: ...LS 1st Order HS or 2nd Order HS 40 to 12dB Output Clip Indicator 0 21ms Output Source A B C A B All None Xover HPF LPF 12dB BWorth 12dB Bessel 12 dB Linkwitz 18dB Bessel 18dB Bworth 24dB Bworth 24dB...