Ashley AW180 Owner'S Manual Download Page 5

 

5

ASSEMBLY

6

10

9

7

8

3

2

5

4

1

Kit Contents

Key

Part Description

Qty.

1

26414

Clamp, Top Trim

1

2

26735

Right Panel, Facade

1

3

26736

Left Panel, Facade

1

4

26734

Central Panel, Facade

1

5

892455-3

Trim, Facade Side-Left

1

6

891435-1

Trim, Facade Top-Left

1

7

891435-2

Trim, Facade Top-Right

1

8

892455-4

Trim, Facade Side-Right

1

9

444-1B-S-2

Corner Key W/ Screw

2

10

444-2

Blank Corner Key

2

INSERT KEYS BEHIND FLANGE OF TRIM AS 

SHOWN. BLANK CORNER KEY MUST BE IN-

STALLED FIRST. INSERT SECOND KEY. ADJUST 

TRIM AND TIGHTEN SET SCREWS.

ASSEMBLY INSTRUCTIONS

1.  Position stove in 

fi

 replace. Align facade panels with 

fi

 replace 

and top of stove. The panels should be 

fl

 at against the 

fi

 replace 

and standing vertical. 

Notes:   The side facade pieces go behind the top  

 

 piece. 
  

The facade must be installed before unit is set  

 

 into 

its 

fi

 nal position.

2.  Mark the location of the facade panels along the top of the 

stove with a pencil. The mark will be used to realign the panels 
later.

3.  Slide stove out of 

fi

 replace far enough to be able to work 

behind facade panels.

4. Realign 

the 

fi

 rst side panel with the mark made previously. 

5.  Using the predrilled holes in the facade panel as a guide; mark 

and drill holes for the self tapping screws used to mount the 
facade panel. See illustration on right below.  

Note:  

Align the mounting screws with the center of the   

 

predrilled holes to allow for adjustment.

6.  Repeat steps 4 and 5 for the other side panel.
7.  Attach side panel trim as shown. See illustration on left below.
8.  Attach top panel retainer with two self tapping screws.
9.  Ensure venting is attached properly.
10.  Align the top panel with the retainer and side panels
11.  Attach top panel trim. 
Note:  

Stove and facade panels should realign with 

fi

 replace to  

 

allow the panels to be 

fl

 at against 

fi

 replace and standing  

 vertically.

Summary of Contents for AW180

Page 1: ...IONS THIS MANUALWILLHELPYOU TO OBTAIN EFFICIENT DEPENDABLE SERVICE FROM THE HEATER AND ENABLEYOU TO ORDER REPAIR PARTS CORRECTLY KEEP IN A SAFE PLACE FOR FUTURE REFERENCE French version is available f...

Page 2: ...655mm x 749mm x 685mm Combustion Chamber Width x Depth 12 7 x 11 9 322mm x 302mm Volume Cubic Feet 0 75 cubic feet Door Opening Width x Height 16 8 x 9 406mm x 228mm Pyroceramic Glass Door Viewing Wi...

Page 3: ...of the three offered kits A Pedestal Kit SA180P B Leg Kit SA180L C Fireplace Insert SA180i Refer to the instructions found inside each kit for proper assembly A 7 16 socket wrench A 5 16 socket Best i...

Page 4: ...otect the finish on your new stove FREESTANDING LEG ASSEMBLY 1 Unpack the kit and ensure all components are present Qty Description Part 4 Cast Iron Legs 40566 8 1 4 20 UNC Bolts 83339 8 Flat Washers...

Page 5: ...set into its final position 2 Mark the location of the facade panels along the top of the stove with a pencil The mark will be used to realign the panels later 3 Slide stove out of fireplace far enou...

Page 6: ...ur Side wall Paroi Lat rale Side wall Paroi Lat rale S de a a o at a e C B A Dimension Inch mm A Backwall to Stove 12 305 B Sidewall to Stove 12 305 C Sidewall to Flue 13 330 D Wall to Stove Angled In...

Page 7: ...facturers of listed floor protectors include Imperial Metal Products and Hy C among others To calculate R Values for alternative methods see Alternate Floor Protector Calculation Methods in the back o...

Page 8: ...2 To attach the leg model use two 3 8 16 UNC bolts through the floor The heater must be electrically grounded to the steel chassis of the mobile home with 8 GA copper wire using a serrated or star wa...

Page 9: ...arrier and tight fitting windows and or has any powered devices that exhaust house air 5 There is excessive condensation on windows in the winter 6 A ventilation system is installed in the house If an...

Page 10: ...ote that it is the chimney and not the stove which creates the draft effect your stove s performance is directly dependent on an adequate draft from your chimney Do not connect this unit to a chimney...

Page 11: ...any structural components of the existing fireplace or chimney nor reduces protection of combustible materials required by national building codes Consult with your local building or fire authority b...

Page 12: ...essional Make sure there are no cracks loose mortar or other signs of deterioration and blockage Have the chimney cleaned before the stove is installed and operated When connecting the stove through a...

Page 13: ...nd a minimum 24 gauge ventilated wall thimble which has two air channels of 1 25 4 mm each construct a wall pass through There shall be a minimum 6 152 4 mm separation area containing fiberglass insul...

Page 14: ...d 211 To insure a good draft the total length of the stove pipe should never exceed 8 to 10 2 4m to 3 04 m Except for cases of vertical installation cathedral roof style where the smoke exhaust system...

Page 15: ...nufacturer and install the ceiling support package or wall pass through and T section package firestops where needed insulation shield roof flashing chimney cap etc Maintain proper clearance to the st...

Page 16: ...iencies and lower emissions generally result when burning air dried seasoned hardwoods as compared to softwoods or to green or freshly cut hardwoods DO NOT BURN Burning these materials may result in r...

Page 17: ...aper and kindling wood it is recommended that you warm up the chimney This is done in order to avoid back draft problems often due to negative pressure in the house If such is the case open a window s...

Page 18: ...chimney as lost energy Therefore efficiency calculated using the lower heating value of wood will be higher than efficiency calculated using the higher heating value In the United States all woodstov...

Page 19: ...ol then inspect the chimney for damage If no damage results perform a chimney cleaning to ensure there is no more creosote deposits remaining in the chimney ASH DISPOSAL Whenever ashes get 3 to 4 inch...

Page 20: ...oove apply a high temperature silicone sold for this purpose and install the new gasket You may light up your stove again approximately 24 hours after having completed this operation This unit s door...

Page 21: ...ossible Remedies Unplug blower first if equipped Cool exhaust flue gasses Use double or triple wall external chimney Burning unseasoned wet wood Use dry seasoned hardwood Smoke rolls out when feed or...

Page 22: ...rick 4 5 X 7 5 X 1 25 2 18 891783 Firebrick 3 X 4 1 2 3 19 26706 Right Brick Retainer 1 20 26705 Left Brick Retainer 1 21 610073 Rear Access Panel 1 22 26703 Window Clamp 4 23 69953 Door Assembly 1 24...

Page 23: ...23 29 28 27 32 31 30 26 25 33 13 29 12 8 7 18 16 20 19 17 3 23 6 9 22 10 2 11 34 1 15 21 24 14 4 5 WIRING SCHEMATIC...

Page 24: ...Qty 35 26731 MAIN WRAP 1 36 26732 CENTER SUPPORT 1 37 26733 BASE PLATE 1 38 852049 Ashley LOGO 1 39 26730 BACKING PLATE 1 IN ORDER TO MAINTAIN WARRANTY COMPONENTS MUST BE REPLACED USING ORIGINAL MANUF...

Page 25: ...given with a required thickness T in inches R 1 k x T c C factor is given R 1 C 2 Determine the R value of proposed alternate floor protector a Use formulas in step 1 above to calculate R value of pro...

Page 26: ...hed to the stove When ordering repair parts always give the following information as shown in this list HOW TO ORDER REPAIR PARTS 1 The part number AW180 2 The part description _______________________...

Page 27: ...______ Reason for Purchase Alternative Heat Main Heat Source Decoration Cost Other _________________________ What was the determining factor for purchasing your new appliance _______ I have read the o...

Page 28: ...CUT HERE CUT HERE Fold Here Fold Here U S Stove 227 Industrial Park Road South Pittsburg TN 37380 USA Fold Here PLACE STAMP HERE...

Reviews: