FLOOR PROTECTION
This heater must have a non-combustible
fl
oor protector
(ember protection) installed beneath it if the
fl
oor is of com-
bustible material. If a
fl
oor pad is used, it should be UL listed
or equal. The
fl
oor pad or non-combustible surface should
be large enough to cover at least the area under the product
and 6 in. (152 mm) beyond the front and beyond each side of
the fuel loading and ash removal openings. Your heater will
need a minimum 31” x 38”
fl
oor protector. Floor protection
must extend under and 2 in. (50.8mm) to each side of the
chimney tee for an interior vertical installation (see FIGURE 2).
Canadian Installations require a minimum of 450 mm [17.7”]
beyond the front of the unit and 200mm [7.8”] beyond each
side of the unit. A Floor Protector of ¼ inch thick is recom-
mended for this installation.