Ashland EPH30 Operation, Performance, Specifications And Parts Manual Download Page 6

6

Effluent Pumps

Model: EPH30

Receiving and Installation

It is recommended that the level control float should be  

set to insure that the liquid in the sump never drops  

below the top of the motor housing. The level control

should have adequate clearance so it cannot hang up in  

it’s swing and that the pump is completely submerged

when the level control is in the “Off ” mode. Minimum 

tether length is 3.50”. 

By adjusting the cord tether the control level can be 

changed. DO NOT USE THE POWER CABLE TO LIFT 

PUMP. 

 Pump-Down Test - Be sure pump has been plugged in,   

lowered into the basin or sump, check the system by    

filling with liquid and allowing the pump to operate  

 

 through its pumping cycle. The time needed to

 empty the system, or pump-down time along with the    

volume of water, should be recorded.

Thermal Protection

The normally closed (N/C) over temperature sensor is  

embedded in the motor windings and will detect exces-

sive heat in the event an overload condition occurs.

The thermal sensor will trip when the windings become  

too hot and will automatically reset when the pump

motor cools to a safe temperature. 
In the event of an over temperature, the source of this con-

dition should be determined and repaired immediately. Ther-

mal protection shall not be used as a motor overload device. 

Maintenance

Minimal maintenance is required. Perform the following 

checks when pump is removed from operation or when 

pump performance deteriorates:

  a).  Inspect motor chambers for oil level and   

 

   contamination.

  b).  Inspect impeller and body for excessive build-up or  

   clogging.

  c).  Inspect motor and bearings.

  d). Inspect seal for wear or leakage.
 

Servicing

Cooling Oil

 - Anytime the pump is removed from  

operation, the cooling oil in the motor housing should be 

checked visually for oil level and contamination. To check 

oil, set unit upright. Remove pipe plug from housing. 

With a flashlight, visually inspect the oil in the housing to 

make sure it is clean and clear, light amber in color and 

free from suspended particles. Milky white oil indicates 

the presence of water. Oil level should be just above the 

motor when pump is in vertical position. 

Oil Testing

•  Drain oil into a clean, dry container by placing pump on  

  it’s side. Remove pipe plug, from housing.

•  Check oil for contamination using an oil tester with a   

  range to 30 Kilovolts breakdown.

•  If oil is found to be clean and uncontaminated  

  (measuring above 15 KV. breakdown), refill the housing.

•  If oil is found to be dirty or contaminated (or measures  

•  If oil is found to be dirty or contaminated (or measures  

  below 15 KV. breakdown), the pump must be carefully  

  inspected for leaks at the shaft seal, cable assembly,   

  o- ring and pipe plug, before refilling with oil. To locate  

  the leak, perform the following pressure tests.

After leak is repaired, dispose of old oil properly, and 

refill with new oil. 

     

Pressure builds up extremely fast, increase    

    

pressure by “TAPPING” air nozzle. Too much

    

pressure will damage seal.    

 

 

    

DO NOT exceed 10 P.S.I.

Motor Housing Pressure Test:

If oil has been drained, fill to normal level before perform-

ing pressure test. Remove pipe plug from motor housing.
Apply pipe sealant to pressure gauge assembly and tight-

en into hole. Pressurize motor housing to 10 P.S.I. Use 

soap solution around the sealed areas above the oil level 

and inspect joints for “air bubbles”. For sealed areas 

below oil level, leeks will seep oil. If, after five minutes, 

the pressure is still holding constant, and no “bubbles” /

oil seepage is observed, slowly bleed the pressure and 

remove the gauge assembly. Replace oil. Leak must be 

located and repaired if pressure does not hold.

Oil Replacement Motor Housing 

Remove pipe plug from motor housing.

Drain all oil (if not already done so) from motor housing  

and dispose of properly per Local Code. Set pump 

upright and refill with new cooling oil, see “Cooling Oil” 

chart. Fill to just above motor (0.34L) as an air space 

must remain in the top of the motor housing to compen-

sate for oil expansion. Apply pipe thread compound to 

threads of pipe plug then assemble to motor housing. 

Check that o-ring is in place and does not need to be 

replaced. Reassemble cord cap to motor housing.
  

DO NOT overfill oil. Overfilling of housing    

   

with oil can create excessive and dangerous  

   

hydraulic pressure which can destroy the    

   

pump and create a hazard. Overfilling  

 

   

oil voids warranty.

 

   

Cooling Oil Recommended Supplier/Grade

  BP  

  Enerpar SE100

  Conoco  

  Pale Paraffin 22

  Mobile  

  D.T.E. Oil Light

  Shell Canada  

  Transformer-10

  Texaco  

  Diala-Oil-AX

  

 

 

       Before any service work is   

   

 

 

       done, disconnect and lock  

   

out electrical power to pump. 

 

WARNING

 

   

Summary of Contents for EPH30

Page 1: ...replacement parts information OPERATION PERFORMANCE SPECIFICATIONS and PARTS MANUAL EPH30 3 10 HP High Head Effluent Pump Effluent Pump Model EPH30 Danger indicates an imminent hazardous situation wh...

Page 2: ...an contact with pumped fluid is possible Risk of electrical shock To reduce risk of electrical shock always disconnect pump from source before handling Lock out power tag Effluent Pumps Model EPH30 Ge...

Page 3: ...5 230 1 7 0 3 5 8 75 6 3 9 4 Cast Iron Cast Iron Cast Iron SS Description To pump domestic commercial and light industrial sewage Physical Data DISCHARGE SIZE 1 1 2 NPT IMPELLER TYPE VORTEX CABLE LENG...

Page 4: ...luent Pumps Model EPH30 Specifications and Performance EPH30 PERFORMANCE CHART Total Lift feet 10 15 20 25 30 34 GPM 45 40 32 24 11 0 HEAD FEET 40 35 30 25 20 15 10 5 0 0 10 20 30 40 50 GALLONS PER MI...

Page 5: ...e pump Both a check valve and a shut off valve are recommended for each pump The check valve is used to prevent backflow into the sump The shut off valve is used to manually stop system flow during pu...

Page 6: ...lacing pump on it s side Remove pipe plug from housing Check oil for contamination using an oil tester with a range to 30 Kilovolts breakdown If oil is found to be clean and uncontaminated measuring a...

Page 7: ...and press the upper bearing on the rotor shaft applying force to the inner race of the bearing only In the same manner replace lower bearing 49 onto rotor shaft Seal Plate Lubricate and set o ring in...

Page 8: ...at control panel before starting disassembly operation Never rely on opening circuit breaker only Operating pump builds up heat and pressure allow time for pump to cool to room temperature Installing...

Page 9: ...al times by plugging and unplugging cord Check for clogged vent hole in pump case Inlet holes in pump base are clogged Remove pump and clean the openings Vertical pumping distance is too high Reduce d...

Page 10: ...RING 1 3 091EPH303 SHAFT SEAL 1 4 091EPH304 STATOR ASSY 1 5 091EPH305 SEALING RING 1 6 091EPH306 SCREW 1 7 091EPH307 POWERCORD ASSY 1 8 091EPH308 VOLUTE 1 9 091EPH309 SEAL PLATE 1 10 091EPH310 ROTOR A...

Page 11: ...ed warranties of merchantability and fitness for a particular purpose No warranties or representations at any time made by any representative of Ashland Pump shall vary or expand the provisions of thi...

Page 12: ...ferencia Por favor visite nuestra p gina web y el Centro de Productos si desea instrucciones adicionales sobre instalaci n operaci n y piezas de repuesto Advertencia indica una situaci n peligrosa inm...

Page 13: ...nes de agua potable Las instalaciones cableado y conex iones de empalmes deben realizarse en concordancia con el C digo de Electricidad Nacional y con todos los c digos estatales y locales pertinentes...

Page 14: ...Hierro forjado EJE DEL MOTOR SST HARDWARE SUS ANILLOS O NBR SELLOS Mec nico simple Carbono cer mico RODAMIENTO SUPERIOR 608 2RZ RODAMIENTO INFERIOR 6202 Numero de modelo Fecha MFG Fase HP SN IMPORTAN...

Page 15: ...s Modelo EPH30 Especificaciones EPH30 TABLA DE DESEMPE O EPH30 CURVA DE DESEMPE O CABEZA PULGADA GALONES POR MINUTO La elevaci n Total pies 10 15 20 25 30 34 GPM 45 40 32 24 11 0 40 35 30 25 20 15 10...

Page 16: ...cuentra en la placa de identificaci n y reg strelo en este manual para referencia futura Conexiones el ctricas Apague el interruptor autom tico del circuito antes de enchufar o desenchufar el interrup...

Page 17: ...e la carcasa Verifique si hay contaminaci n en el aceite utilizando un probador con un rango de 30 kilovoltios Si el aceite est limpio y sin contaminantes m s de 15KV vuelva a llenar la carcasa Si el...

Page 18: ...eje solo aplique fuerza a la parte interior del rodamiento Reemplace el rodamiento inferior 49 de la misma manera Placa del sello lubrique y coloque el anillo O en la placa del sello Coloque la placa...

Page 19: ...tes de bajar la bomba al contenedor conecte las l neas el ctricas y arranque el motor El impulsor debe girar en sentido anti horario viendo hacia el impulsor Servicio y reparaci n Importante antes de...

Page 20: ...si hay obstrucciones en el orificio de ventilaci n en la carcasa La distancia vertical de bombeo es demasiado alta Reduzca la distancia o cambie la descarga de la bomba Los orificios de entrada en la...

Page 21: ...91EPH303 SELLO DEL EJE 1 4 091EPH304 ESTATOR ASSY 1 5 091EPH305 AILLO DE SELLO 1 6 091EPH306 TORNILLO 1 7 091EPH307 CABLE DE ALIMENTACION 1 8 091EPH308 VOLUTA 1 9 091EPH309 PLACA DE SELLO 1 10 091EPH3...

Page 22: ...ciada por el n mero de serie del producto No hay otra garant a expl cita o impl cita que cubra su producto Ashland Pump Sin limitar lo anterior Ashland Pump niega espec ficamente las garant as impl ci...

Page 23: ...e pompe Prenez le temps pour lire attentivement les instructions avant d utiliser ce produit Nous recommandons fortement que vous gardiez ce manuel d instructions dans un endroit s r pour la r f rence...

Page 24: ...ions et l information de s curit pourrait causer des blessures corporelles graves la mort et ou des dommages mat riels Chaque pompe d Ashland est individuellement test e en usine pour assurer la perfo...

Page 25: ...CHARGE 1 1 2 NPT TYPE DE L IMPELLEUR Vortex Fonte LONGUEUR DU C BLE 20 Manipulation De Liquide TAILLE DES SOLIDES 3 4 GAMME DE PH ACCEPTABLE 6 8 Temperature STATOR MAXIMAL 120 C Donnees Techniques TY...

Page 26: ...EPH30 Specifications et Performance EPH30 DIAGRAMME DE LA PERFORMANCE EPH30 COURBE DE LA PERFORMANCE TETE PIEDS GALLONS PAR MINUTE Levage total pieds 10 15 20 25 30 34 GPM 45 40 32 24 11 0 40 35 30 2...

Page 27: ...d anti retour et une vanne d arr t sont recommand s pour chaque pompe Le clapet d anti retour est utilis pour emp cher le reflux dans le puisard La vanne d arr t est utilis e pour arr ter manuellemen...

Page 28: ...emps de pomper vers le bas avec la volute ou l eau devraient tre enregis tr es Protection Thermique Le normalement ferm N F sur l e capteur de temp ra ture est noy dans les enroulements du moteur et p...

Page 29: ...t une force sur la bague int rieure du roulement seulement De la m me mani re remplacez le palier inf rieur 49 sur l arbre de rotor Bo tier d Etanch it Graissez et mettez l anneau d O dans la rainure...

Page 30: ...panneau La pompe d exploitation accumule la chaleur et la pression laissez le temps la pompe pour refroidir la temp rature ambiante ATTENTION Pompes pour effluent Mod les EPH30 Installation Installati...

Page 31: ...trous d entr e dans la base de la pompe sont bouch s Retirez la pompe et nettoyez les ouvertures La distance de pompage vertical est trop lev R duisez la distance ou modifiez les raccords de d charge...

Page 32: ...PH303 JOINT D ARBRE 1 4 091EPH304 ASSEMBLEE DU STATOR 1 5 091EPH305 ANNEAU D ETANCHEITE 1 6 091EPH306 VIS 1 7 091EPH307 CORDON D ALIMENTATION 1 8 091EPH308 VOLUTE 1 9 091EPH309 PLAQUE D ETANCHEITE 1 1...

Page 33: ...u produit Il n y a aucune autre garantie expresse ou implicite couvrant votre Ashland Pump Sans limiter ce qui pr c de Ashland Pump d cline sp cifiquement les garanties implicites de qualit marchande...

Reviews: