Installation and Maintenance Instructions for  
F5504 Differential Pressure Gauges

© Ashcroft Inc. 2022, 250 East Main Street, Stratford, CT 06614-5145, USA, Tel: 203-378-8281, Fax: 203-385-0357, www.ashcroft.com 

All sales subject to standard terms and conditions of sale. F5504_gauge_i&m_008-10299_RevA_05-02-22

5

•  Use only with the mechanical process connection 

provided – regarding the configuration, see order 
code on the device type label, with a matching 
threaded seal.

•  When connecting the device, the pipes must be 

depressurized.

• The pressure metering pipe must be laid inclined in such 
a way that, for example, for measurements of fluids no air 
pockets can form, and for measurements of gases no water 
pockets. If the necessary incline is not achieved, then at 
suitable points water separators or air separators must be 
installed.

• The pressure metering pipe must be kept as short as possible 
and laid without sharp bends, to avoid delays.

•  The instruments pressure ports are marked by “+” and “-” 

symbols: 

 

“+” port must be connected to the higher pressure 

 

“-” port must be connected to the lower pressure.

•  With liquid measurement media, the pressurized connection 

pipe must be degassed, since any gas bubble inclusions result 
in measurement error.

7.4 Starting up

 

The precondition for start-up is proper installation of all 
electrical feed lines and metering pipes. All connecting lines 
must be installed so that no mechanical forces can act on the 
device. Before start-up, the seal on the pressurized connection 
line must be leak checked.

7.4.1 Zero point adjustment

 

The differential pressure gauge is factory adjusted therefore in 
normal case adjustment during installation is not necessary. On 
this devices zero point adjustment on site is possible. For this, 
proceed as follows:

• Equalize pressure in both chambers.

• Disassemble screw plug
• Use zero point adjustment screw to set the pointer to zero.
• Mount screw plug

Filled Models need to be vented before 
commissioning by opening the air valve on the upper 
side of instrument!

8 SERVICING

The device is maintenance-free. However, to ensure reliable 
operation and a long lifetime for the device, we recommend 
that it is checked regularly.

8.1 Safety

 

When undertaking servicing work on the device, the pressure 
lines must be depressurized, the electrical connections 
isolated, and secured against being switched back on.

8.2 Gauge performance and recalibration

 

The check on function and recalibration is carried out at regular 
intervals, depending on the application. The precise testing 
cycles should be adjusted in line with the operating conditions 
and ambient conditions. In the event of various device 
components interacting, the operating instructions for all other 
devices should also be taken into account.

•  Check on display.

•  Check on function, in conjunction with downstream components.

•  Check of pressurized connection pipes for seal condition.

8.3 Cleaning and maintenance

 

Cleaning is carried out using a non-aggressive cleaning agent, 
with the ventilation valve closed and respecting the protection 
category of the device.

9  

FAULTS

9.1 Safety

 

Defective or faulty pressure gauges put the operational safety 
and process safety of the plant at risk, and can lead to a risk or 
injury to persons, the environment or the plant.

9.2 In the event of failure

 

All defective or faulty devices must be taken out of service. 
If a repair is required, the device must be sent directly to our 
Repairs Department. Please contact your Ashcroft distributor 
or Ashcroft directly for complete instructions.

9.3 Indications of failure

•  Jerky or random movement of the pointer
•  Pointer does not set to zero with pressure applied to both 

sides

•  Indications that the measurement system seal 

(diaphragm) 

has been breached 

(discoloration to dial display or of filling 

liquid) 

•  Bent or loose pointer
•  Cracked window
•  Leaks when the device is filled
•  Damage to housing
In these instances, repair or replacement of the pressure gauge 
is always required.