OPERATION
AND
MAINTENANCE
INSTRUCTION MANUAL
ADU-03ST Manual Dental Control System
HVE and Saliva Ejector options
Page 1: ...OPERATION AND MAINTENANCE INSTRUCTION MANUAL ADU 03ST Manual Dental Control System HVE and Saliva Ejector options ...
Page 2: ...t S E Woodinville WA 98072 International 425 487 3157 Toll Free 800 426 5913 www aseptico com info aseptico com TABLE OF CONTENTS Introduction 1 Package Contents Options 1 Setting Up the Unit 2 Figure 1 Case Contents 2 Figure 2 ADU 03ST Setup 2 Remote Setup 3 Figure 3 Vacuum Systems Quick Connects 3 Operation Functions 4 Figure 4 Operation Functions 4 Unit Operation 5 Figure 5 Air Water Syringe 5 ...
Page 3: ...ars of reliable service Please read the instructions provided in this manual to receive the best and longest service from your Aseptico equipment Separate manuals may be provided to cover the operation and maintenance of hand pieces or other accessories for your unit Handpieces are purchased separately PACKAGE CONTENTS TA 90D 3 Way Air Water Syringe with Tips NWS 8 Self Contained Clean Water Syste...
Page 4: ... comes factory mounted on a tripod stand 2 Remove the system from the carrying case Fig 1 fully extend tripod legs and stand the system up Fig 2 3 Unit height is adjusted by loosening the adjustment handle on tripod raise or lower system then tighten adjustment handle AA 25ST Saliva Ejector Assembly Optional SETTING UP THE UNIT Figure 2 ADU 03ST Setup Fully Extend Tripod Legs Tripod Height Adjustm...
Page 5: ...tach saliva ejector hose to the quick connect located on top of waste container and then place ejector valve into the holder located on left side of unit To remove waste container assembly push in on snap ring tab and pull the assembly out of Connector Figure 3 HVE Saliva Ejector Connectors AA 21ST HVE System Optional Snap Ring Quick Connectors AA 25ST Saliva Ejector Optional 5 Optional AA 21ST HV...
Page 6: ...ume Evacuator when the HVE valve button is depressed AA 61 Water Out Connector Provides water via standard 1 4 quick disconnect to independent Cavitron or scaler units requiring a water supply Remove the black rubber cap then connect water line to this connector FOR WATER OUT CONNECTIONS ONLY 3 Way Syringe AA 25ST Saliva Ejector Optional AA 21ST High Volume Evacuator Optional Pressure Gauge Figure...
Page 7: ... ensure that tip is securely locked into socket Optional Saliva Ejector Remove the saliva ejector valve from its holder and insert a standard saliva ejector tip Turn the low vacuum toggle switch ON Waste from the vacuum system will collect in the attached plastic bottle When the waste container is 3 4 full it must be emptied to prevent a back up in the system Optional HVE System Remove the vacuum ...
Page 8: ...thers CLEANING Syringe Tip Sterilization 1 Remove contaminated syringe tip 2 Remove all visible signs of contamination before autoclaving 3 Autoclave tip at 132 C 270 F for ten minutes 4 Sterilize between each patient use NOTE Since only the tips can be autoclaved it is recommended that the air water syringe be bagged with a disposable single use plastic sleeve between each patient use Saliva Ejec...