background image

Two alarms indicator

1

/

8

DIN - 96 x 48

J1 line

c

c

U s e r   M a n u a l   •   M . I . U . J 1   -   3 / 0 9 . 0 2   •   C o d .   J 3 0 - 4 7 8 - 1 A J 1   I E

ASCON spa
via Falzarego, 9/11
20021 Bollate
(Milano) Italy
Fax +39 02 350 4243
http://www.ascon.it
e-mail [email protected]

ASCON spa

ISO 9001

C e r t i f i e d

J1 EN-ed3  17-02-2009  15:05  Pagina 1

Summary of Contents for Gammadue Series

Page 1: ...r M a n u a l M I U J 1 3 0 9 0 2 C o d J 3 0 4 7 8 1 A J 1 I E ASCON spa via Falzarego 9 11 20021 Bollate Milano Italy Fax 39 02 350 4243 http www ascon it e mail support ascon it ASCON spa ISO 9001...

Page 2: ...Two alarms indicator 1 8 DIN 96 x 48 J1 line c c J1 1 2 1406 3 J1 EN ed3 17 02 2009 15 05 Pagina 1...

Page 3: ...336 EEC amended by the European Community directive 92 31 EEC 93 68 EEC 98 13 EEC and the following regulations Regulations on RF emissions EN61000 6 3 2001 residential environments EN61000 6 4 2001 i...

Page 4: ...pecial functions OP1 OP2 Alarms Operating mode OP1 OP2 Table of contents TABLE OF CONTENTS 1 INSTALLATION Page 4 2 ELECTRICAL CONNECTIONS Page 8 3 PRODUCT CODING Page 14 4 OPERATIONS Page 18 5 DISPLAY...

Page 5: ...with the B symbol related to the European Community directive on electrical protection and electromagnetic compatibility B To prevent hands or metal touching parts that may be electrically live the i...

Page 6: ...TAILS 1 3 PANEL CUT OUT 48 mm 1 89 in 110 mm 4 33 in 10 mm max 0 39 in max 96 mm 3 78 in 10 mm max 0 39 in max 45 0 6mm 1 78 0 023in 65mm min 2 56in min 92 0 8 mm 3 62 0 031 in 113 mm min 4 45 in min...

Page 7: ...ONDITIONS B Special conditions M Altitude 2000 m T Temperature 50 C Rh Humidity 95 P Conducting atmosphere Use filter Warm up Use forced air ventilation Use 24Vac supply version Suggestions Forbidden...

Page 8: ...e instrument 1 5 3 CLAMPS REMOVING 1 Insert the screwdriver in the clips of the clamps 2 Rotate the screwdriver 1 5 4 INSTRUMENT UNPLUGGING B 1 Push and 2 Pull forward to remove the instrument 1 5 PAN...

Page 9: ...q 1 4 mm 0 055 in max Fork shape AMP 165004 5 5 mm 0 21 in Stripped wire L 5 5 mm 0 21 in 2 1 TERMINAL BLOCK 1 B 2 Electrical connections N L RS485 1 2 3 4 5 6 7 8 9 10 11 12 19 20 23 24 25 26 27 28 2...

Page 10: ...ns The supply wiring should be rout ed away from the power cables Avoid using electromagnetic con tactors power Relays and high power motors nearby Avoid power units nearby espe cially if controlled i...

Page 11: ...install a circuit breaker on the instrument power supply line that is clearly identified with that instrument or group of instruments The breaker shall be easily accessible by the operator 4 The instr...

Page 12: ...installations 2 3 2 MAIN UNIVERSAL INPUT B A L J K S R T B N E W thermocouple type Connect the wires with the polarity as shown Always use compensation cable of the correct type for the thermocouple...

Page 13: ...36 11 12 1 mA 24Vdc External shunt 2 5 Transmitter 4 20mA PV 36 11 12 1 mA 2 3 4 ALARM OUTPUTS B OP1 output OP2 output Fuse Load 31 32 1 Fuse Load 28 29 1 30 1 Load Vac Fuse NC C NO Vac Notes 1 Varist...

Page 14: ...2 3 4 O N Galvanic isolation 500Vac 1 min Compliance to the EIA RS485 standard for Modbus Jbus Setting dip switches A Please read gammadue and deltadue indica tor series serial communication and con...

Page 15: ...ct coding is accessible from the front panel by means of the procedure described in section 5 2 page 28 P N J1 3150 0000 CONF S N A0A 0450 2210 V L N 100 240V 50 60 Hz 4W B C D J1 1 2 1406 3 L M N I P...

Page 16: ...24Vdc 15 25 5 The product code indicates the specific hardware configuration of the instrument that can be modified by authorized personnel only User manual F Italian English std 0 French English 1 Ge...

Page 17: ...ation code O P Q R 2300 TC T Cu CuNi 0 TCKChromel AlumelIEC584 0 TC S Pt10 Rh Pt IEC584 0 Input type and range I Dc input 0 50mV linear TR Pt100 IEC751 0 1 Dc input 10 50mV linear 1 Custom input and r...

Page 18: ...alarm 1 AL1 active 2 M Deviation Band Alarm type and function Non active Sensor break alarm Absolute 6 5 4 3 2 1 0 7 Rate alarm AL1 only Active High Active Low Active Out Active High Active Low Activ...

Page 19: ...firmation Menu access Min and Max values display Alarm status LEDs reds AL1 ON AL2 ON 88888 _____ 88888 Input value 1 In engineering uits Note 1 The colour of the dislplay is set through field m of th...

Page 20: ...dify the value see page 20 The value is entered when the next parameter is selected by pressing the R key Until the or are pressed or if you wait for 30 sec onds the parameter value is not inserted Pr...

Page 21: ...276 0 277 0 none ph Unit C f C f Engineering Units Degree Centigrade Degree Fahrenheit Degree Centigrade Degree Fahrenheit No unit defined Ph Access the alarm threshold menu Select the AL 1 threshold...

Page 22: ...5 0 0 5 0 Alarm threshold menu AL1 alarm threshold AL1 hysteresis AL2 alarm threshold AL2 hysteresis Alarm internal reference value engineering unit Back to AL 1SP Back to the operator mode Must be e...

Page 23: ...re configured different than zero are shown during the parameterisation phase fields op page 17 PASS Unit Conf none OK Con1 Con2 4 3 5 CONFIGURATION MENU No Yes Entering digits I L M N of the configur...

Page 24: ...9 engineering units Communications protocol M buS jbuS Baud rate 1200 2400 4800 9600 Serial comms address 1 247 Password 0 9999 factory default 33 Back to the Con 1 parameter Value Description C Centi...

Page 25: ...ocking function is activa ted on start up bloc page 25 Sensorbreakfunction page26 Rate alarm AL1 only page 26 AL1 alarm threshold AL2 alarm threshold Parameters to set the threshold of AL1 and AL2 ala...

Page 26: ...ition Default values direct Op 2a Op 1a AL 2Op AL 1Op AL1 AL2 latching and blocking function For each alarm it is possible to select one of the following func tions none none Ltch acknowledge bloc blo...

Page 27: ...shold On Off On Off REF On Off Active high Active low hy high range low range Alarm threshold ABSOLUTE ALARM During the configuration phase page 17 set fields o and p to value 2 actve high or 3 acti v...

Page 28: ...sqrt enabled none disabled Cut off square root result This parameter allows the user to round to zero those results that are not meaningful Setting range 0 9999 Default value 0 CUt 1 in1 Cn in 1Hi in...

Page 29: ...rel 0301 030 5 1 DISPLAYING THE PROCESS VARIABLE 1406 3 in1 Unit 1406 3 C Back to IN1 IN1 reading Operator mode Operator mode Engineering units Table 2 page25 IN1 reading 2nd part of confi guration i...

Page 30: ...AND OPERATING PROCEDURE The commands can be entered in 2 ways 6 1 KEYPAD see page 30 Keypad lock Outputs lock 6 SERIAL COMMUNICATIONS see the manual on this topic 29 6 Commands 6 COMMANDS J1 EN ed3 17...

Page 31: ...ed to the OFF status by pressing and hold ing the keys and simultaneously for 2 seconds To confirm the output lock unlock the display flashes once To unlock the outputs press the keys simultaneously a...

Page 32: ...C IEC 751 C F selectable 2 or 3 wire connection Burnout with any combination Max wire resistance 20 max 3 wires Input drift 0 35 C 10 Env Temp 0 35 C 10 Wire Res DC input current with 2 5 external sh...

Page 33: ...ral characteristics Power supply PTC protected Safety UL and cUL Approvals Electromagnetic compatibility Protection EN60529 IEC 529 Parameter and configuration data are stored in a non volatile memory...

Page 34: ...from defects in material and workmanship for 3 years from the date of delivery The warranty above shall not apply for any failure caused by the use of the product not in accordance with the instructio...

Page 35: ...ry input Keypad lock Current transformer Outputs lock mA Remote setpoint Start up function Volt Remote setpoint Timer function Feedback potentiometer Memorized Remote Setpoint programmer Logic mA mV m...

Page 36: ...GREECE CONTROL SYSTEM Phone 30 31 521 055 6 Fax 30 31 515 495 BRANCH OFFICE Phone 30 1 646 6276 Fax 30 1 646 6862 PORTUGAL REGIQUIPAMENTOS LDA Phone 351 21 989 0738 Fax 351 21 989 0739 SPAIN INTERBIL...

Page 37: ...36 J1 EN ed3 17 02 2009 15 05 Pagina 36...