Ascon tecnologic TRH 11 Manual Download Page 1

TRH 11

 

 

RELATIVE HUMIDITY PROBE 

 

 

 

cod.: ISTR MTRH11ENG02 – Ver. 02

 

 

ASCON TECNOLOGIC S.r.l. 

VIALE INDIPENDENZA 56

 

27029 VIGEVANO (PV) ITALY

 

TEL.: +39 0381 69871 

FAX: +39 0381 698730

 

www.ascontecnologic.com

 

[email protected]

 

 
 

PREVIOUS STATEMENT

 

In this manual are contained all the necessary information for a 
correct installation and the instructions for the use and the 
maintenance of the product; we recommend, therefore, to read 
carefully the following instructions.  
The maximum care has been used in the realisation of this 
document, anyway Ascon Tecnologic S.r.l. does not assume any 
responsibility deriving from the use of itself.  
The same consideration has to be done for each person or Company 
involved in the creation of this manual.  
The herewith issue is an exclusive property of Ascon Tecnologic 
S.r.l. which forbids any reproduction and divulgation, although partial, 
if not expressly authorised.  
Ascon Tecnologic S.r.l. reserves the right to execute aesthetically 
and functional modifications, at any moment and without  any notice. 
 

INDEX 

1 DESCRIPTION 

1.1

GENERAL DESCRIPTION

 

1.2

PROBE DESCRIPTION

 

INSTALLATION AND USE ADVICES 

2.1

USE ALLOWED

2.2

MECHANICAL MOUNTING

 

2.3

ELECTRICAL  CONNECTIONS

 

2.4

ELECTRICAL CONNECTION DRAWINGS

3 OPERATING 

MODE 

TROUBLES, MAINTENANCE, WARRANTY 

4.1

ERRORS

4.2

CLEANING

4.3

WARRANTY AND REPAIRS

 

5 TECHNICAL 

DATA 

5.1

ELECTRICAL DATA

5.2

MECHANICAL DATA

 

5.3

MECHANICAL DIMENSIONS AND FIXING DEVICE

5.4

FUNCTIONAL DATA

 

 

1 - DESCRIPTION 

 
1.1 - GENERAL DESCRIPTION 

TRH 11 is a relative humidity probe of capacitive type with 
normalized output current signal 4... 20 mA by 2 wires. 
 

1.2 - PROBE DESCRIPTION

 

 

1 -

 Sensors protective cap 

2 - 

Terminal block 

3 - 

Cable gland M20x1,5 

 

2 - INSTALLATION AND USE ADVICES 

 

2.1 – ALLOWED USE

 

The instrument has been projected as measure 
transducer. 
It has to be reminded that the user has to take care 
that the electromagnetic rules are being respected 
also after the instrument installing, eventually using 

proper filters. 
Whenever a failure or a bad functioning of the instrument may cause 
dangerous situations or damage to people, things or animals it has 
to be reminded that the plant has to be equipped with additional 
electromechanical devices in order to grant the safety. 
 

2.2 – MECHANICAL MOUNTING 

The instrument, into case 80 x 80 mm , is designed for wall mounting. 
Install the instrument as far as possible from electromagnetic 
sources as motors, power relay, relays, electro-valves, etc.. 
Avoid to place the probe into places where are present corrosive and 
polluting gases (see Concentration Maximum Pollutant in the 
Technical Data) and to do so that the probe are installed in ventilated 
position. 
Should be necessary to remove the protective cap, do not cause any 
mechanical stress to the sensors and absolutely avoid touching the 
humidity sensor. 
 