The eventual opening of the housing, the violation of the instrument 
or the improper use and installation of the product will bring about 
the immediate withdrawal of the warranty’s effects.  

PANEL CUTOUT

RECOMMENDED

29

71

min. 12 mm

min. 15 mm

 

In the event of a faulty instrument, either within the period of warranty, 
or further to its expiry, please contact our sales department to obtain 
authorisation for sending the instrument to our company. 
The faulty product must be shipped to Ascon Tecnologic with a detailed 
description of the faults found, without any fees or charge for Ascon 
Tecnologic, except in the event of alternative agreements. 
 
 

7 - TECHNICAL DATA

 

 

7.1 - ELECTRICAL DATA

 

Power supply: 12 VAC/VDC ±10% 

 

Frequency AC: 50/60 Hz 

7.4 - FUNCTIONAL FEATURES

 

Power consumption: 4 VA approx.; 5 VA approx with TVRY 

Temperature Control: ON/OFF mode 

Input/s: 2 inputs for temperature probes: PTC (KTY 81-121, 990

 Ω

 

@ 25°C) or NTC (103AT-2, 10k

Ω

 @ 25°C); 1 digital input for free 

voltage contacts 

Defrost control: interval cycles or at programmed times (Real Time 
Clock Defrosting) by Electric Heating or hot-gas/reverse cycle 
Measurement range: PTC: -50...150°C/-58... 302°F;  

Output/s: up to 4 relay outputs. OUT1: SPST-NO (16A-AC1, 6A-
AC3 250 VAC,1HP 250VAC, 1/2HP 125 VAC); OUT2, 3, 4: SPDT 
(8A-AC1, 3A-AC3 250 VAC,1/2HP 250VAC, 1/3HP 125 VAC) 

NTC: -50...109°C/-58...228°F 
Display resolution: 1° or 0.1° 
Overall accuracy: ±(0.5% fs + 1 digit) 

Electrical life for relay outputs: 100000 op. (om. VDE) 

Sampling rate: 130 ms. 

Installation category:  II 

Serial Interface: RS485 insulated 

Measurement category:  I 

Communication protocol: MODBUS RTU (JBUS) 

Protection class against electric shock: Class II  for Front panel 

Baud rate: 9600 baud 

Insulation:

 

Reinforced insulation between the low voltage part (relay 

outputs) and front panel; Reinforced insulation between the low 
voltage section (relay outputs) and the extra low voltage section 
(supply and inputs); No insulation between supply and inputs; 50 V 
insulation between RS485 and extra low voltage section.

 

Display: 4 Digit Red h 12 mm 
Endurance time of the internal clock without power supply: 4 hours 
approx. by internal condenser 
Compliance: ECC directive EMC 2004/108/CE (EN 61326), ECC 
directive LV 2006/95/CE (EN 61010-1) 

 

 

7.2 - MECHANICAL DATA

 

7.5 - INSTRUMENT ORDERING CODE

 

Housing: Self-extinguishing plastic, UL 94 V0 

 

Dimensions: 33 x 75 mm, depth 75.5 mm 

TLY 26 a b c d ee f

 

Weight: 155 g approx. 

 

Mounting: Flush in panel (max. 12 mm) in 29 x 71 mm hole 

a: REAL TIME CLOCK DEFROSTING

 

Connections: 2.5 mm

2

 screw terminals block 

C

 = Yes 

Degree of front panel protection: IP 65 mounted in panel with gasket 

-

 = No 

Pollution situation: 2 

 

Operating temperature: 0... 50°C 

b: TVRY REMOTE DISPLAY OUTPUT

 

Operating humidity: 30... 95 RH% without condensation 

D

 = Yes 

Storage temperature: -10... +60°C 

-

 = No 

 

 

7.3 - MECHANICAL DIMENSIONS, PANEL CUT-OUT AND 
MOUNTING [mm]

 

c: RS 485 SERIAL INTERFACE

 

S

 = Yes 

64

78

35

5.5

MAX 12 mm

PANEL

 + GASKET

BRACKETS

34

19 28

11.5

Def

Out

-

+

OK

Fan

AUX

Aux

TLY 26

 

-

 = No 

 

d: OUTPUT OUT4

 

R

 = Relay 

= None 

 

ee: SPECIAL CODES

 

 

f: SPECIAL VERSIONS

 

Ascon Tecnologic - TLY26

 

- OPERATING INSTRUCTIONS - Vr. 02 - 04/14 - ISTR MTLY26ENG02 - PAG. 11

 

Summary of Contents for TLY26

Page 1: ... 2 OUTPUTS CONFIGURATION 4 3 TEMPERATURE CONTROL 4 4 CONTINUOUS CYCLE FUNCTION 4 5 COMPRESSOR PROTECTION FUNCTION AND DELAY AT POWER ON 4 6 DEFROST CONTROL 4 7 MANUAL DEFROST 4 8 EVAPORATOR FANS CONTROL 4 9 ALARM FUNCTIONS 4 9 1 TEMPERATURE ALARMS 4 9 2 EXTERNAL ALARM 4 9 3 OPEN DOOR ALARM 4 9 4 ALARM MEMORY 4 10 DIGITAL INPUT 4 11 AUXILIARY OUTPUT 4 12 FUNCTION OF KEYS U AND DOWN AUX 4 13 RS 485 ...

Page 2: ...d rapidly Exiting the Set mode is achieved by pressing the P key or automatically if no key is pressed for 15 seconds After that time the display returns to the normal function mode 2 2 PARAMETERS PROGRAMMING To access the instrument s function parameters press the key P and keep it pressed for about 5 seconds after which the SET led will light up the display will visualised the code that identifi...

Page 3: ...nstallation if necessary using proper filters Whenever a failure or a malfunction of the device may cause dangerous situations for persons thing or animals please remember that the plant has to be equipped with additional devices which will guarantee safety 3 2 MECHANICAL MOUNTING The instrument in case 33 x 75 mm is designed for flush in panel mounting Make a hole 29 x 71 mm and insert the instru...

Page 4: ...on differential HSEt and the function mode Func Depending on the function mode programmed on the parameter Func the differential is automatically considered by the regulator with positive values for a Refrigeration control Func CooL or with negative values for a heating control Func HEAt Out SP off ON HEAt Out time HSEt SP Temp HSEt time CooL ON ON ON ON ON off off off Pr1 Pr1 Temp In the event of...

Page 5: ... is not reached in the time set in the parameter dEFE defrosting is interrupted In order to avoid pointless defrosting the parameter tSdF is foreseen that sets the enablement temperature for defrosting If the temperature measured by the probe is higher than the one set in the parameter tSdF and in the parameter tEdF the defrosting is inhibited NO def defrost tEdF dEF off ON tSdF dint 1 Pr2 Temp de...

Page 6: ...d in normal conditions and disabled in alarm status ALL when one wants the function described as ALL but with inverse working logic output activated in normal conditions and disabled in alarm status When no alarms are present the green LED OK is lit Any active alarm switch on the buzzer and is shown on the instrument display with the lighting up of the AL led and the switching off of the led OK Wh...

Page 7: ...abled the alarm is activated and the instrument visualises AL and the variable set in parameter diSP alternately on the display 10 Switching on switching off Stand by of instrument with contact normally open on closing the input and after the did time the instrument is switched on while it is placed in Stand by when opened 1 defrosting commencement command with contact normally closed similar to d...

Page 8: ... is made to enter the programming from the keyboard whilst a communication through the serial port is in progress the instrument will visualise buSy to indicate the busy state 4 14 ACCESSORIES 4 14 1 PARAMETERS CONFIGURATION BY KEY A01 The instrument is equipped with a connector that allows the transfer from and toward the instrument of the functioning parameters through the device ASCON TECNOLOGI...

Page 9: ...y Lock OFF display free On Lock on tempera ture Pr1 before defrost Lb Lock on label dEF during defrosting and PdEF during post defrosting On OFF Lb OFF 34 Etdu Differential display unlock after defrost 0 30 C F 2 0 Group FAn parameters relative to evaporator fan control Par Description Range Def Note 35 FCOF Fan status with compressor off On OFF On 36 FEdF Fan status during defrost On OFF OFF 37 F...

Page 10: ...active Set Point 4 Switch on Switch off Stand by OFF 1 2 3 4 OFF 64 USrb Function mode key U see Fbd OFF 1 2 3 4 OFF 65 PASS Access Password to parameter functions OFF 9999 OFF Group SEr parameters relative to the serial communication Par Description Range Def Note 66 Add Station address in case of serial communication 0 255 1 Group CLO parameters relative to the internal clock Par Description Ran...

Page 11: ...VDE Sampling rate 130 ms Installation category II Serial Interface RS485 insulated Measurement category I Communication protocol MODBUS RTU JBUS Protection class against electric shock Class II for Front panel Baud rate 9600 baud Insulation Reinforced insulation between the low voltage part relay outputs and front panel Reinforced insulation between the low voltage section relay outputs and the ex...

Reviews: