background image

MTFS SOLAR TIME CLOCK

  

The MTFS unit is designed to give you year round automatic control of pool systems employing a solar 
heating  system.  It  provides  complete  control  of  the  filter  pump  and  the  solar  pump.  By  following  these 
simple installation and operating instructions you will enjoy trouble free operation for many years. 
 

THIS UNIT IS COVERED BY A 1 YEAR LIMITED WARRANTY. Please refer to web site for warranty 
details. 

 

CAUTION: 
DO NOT OPEN THE CASE OF THE MTFS UNIT. IT IS NOT USER SERVICEABLE. IF THE POWER 
CORD  IS  DAMAGED,  IT  MUST  BE  REPLACED  BY  THE  MANUFACTURER  OR  AN  AUTHORISED 
AGENT.  OPENING  THE  CASE  WILL  VOID  YOUR  WARRANTY.      ENSURE  THAT  THE  MTFS  AND 
SURROUNDING AREA IS FREE FROM VERMIN INFESTATION 
 
INSTALLATION 

The MTFS unit is weather resistant, however it should be mounted in a sheltered position where it is not 
exposed to direct weather, splashing or spray from the pool or filtration equipment. 

Electrical building 

regulations specify that theMTFS unit must not be mounted within 3.5 metres of the pool. 
 

Fix the unit to a wall or post, within 1.5 metres of a 240 volt outlet and within 2 metres of the Solar pump 
and  the  filter  pump.  Mounting  points  are  provided  on  the  back.  Two  sets  of  temperature  sensor  cables 
are  supplied.  One  short  (3m)  for  the  pool  and  one  long  (24m)  for  the  roof.  This  MTFS  unit  must  be 
installed in the upright position. (Cables and mains sockets downwards). 
 

Avoid  cutting  the  sensor  leads  (excess  can  be  neatly  coiled).  If  the  cable  is  cut,  it  must  be 
reconnected  with  the  POSITIVE  (stripe)  to  the  POSITIVE,  and  the  NEGATIVE  (no  stripe)  to  the 
NEGATIVE. Do not place any wire joins underground. 

 

Power connection. 

Power  is  supplied  through  a  standard  240  volt  lead.  A  piggyback  socket  is  provided  on  the  lead  if  you 
need to run other appliances from the same mains outlet.

 

Power for the solar pump comes from the left 

hand  side  socket  on  the  bottom  of  the  unit,  power  for  the  filter  pump  comes  from  the  right  hand  side 
socket on the bottom of the unit. 

Maximum pump rating 

1.5HP per pump. 

 

ONLY THE SOLAR PUMP AND FILTER PUMP ARE TO BE CONNECTED TO THE CONTROLLER’S 
OUTLETS.  
MORE THAN THIS WILL DAMAGE THE ELECTRONICS AND VOID YOUR WARRANTY. 
 
TIMER OPERATION 

 

The timer part of the MTFS unit primarily controls the filter pump. This can be set on or off in half hour 
blocks, or overridden on or off. The solar part of the MTFS unit can also control the filter pump when it 
requires to do so. 
 

To  set  up  the  clock,

  press  the  "TIMER"  button,  followed  by  the  "SETUP"  and  "DISPLAY"  buttons 

together. The display will show "CLOC". Pressing the "+" button will advance the minutes, the "-" button 
will advance the hours. 
 

To clear the filter time blocks,

 press the "TIMER" button and then press and hold down the "SETUP" 

button for 5 seconds . This will clear all timer blocks and display "CLr". 
 

To set up the filter time blocks,

 press the "TIMER" button and then the "SETUP" button, and initially 

"06.00" will be displayed. If filter is required to be on at this time, press the "+" button so the "SET ON" 
LED is on, else press the "-" button so the "SET OFF" LED is on, or the "SETUP" button again, when the 
block

 

time will increment to the next half hour block. Repeat until desired pattern is set up, then wait 5 seconds 
until the displays return to their normal display. 

 
To  check  the  filter  time  blocks,

  press  the  "TIMER"  button,  then  the  "DISPLAY"  button.  If  the  display 

initially shows "End", then all the blocks are off. If the display initially shows "ALL", then all the blocks are 
on. The display will normally show the first time in a day that the filter unit will go on at (indicated by the 
"SET ON" LED being on). Further pressing of the "DISPLAY" button will show when the unit will go off 
(indicated by the "SET OFF" LED being on) and so on until it displays "End", where there are no more 
filter timer blocks to display. 
 

SOLAR OPERATION 
 

The solar part of the MTFS unit primarily controls the heating of the pool to a preset comfort setting using 
solar heating when appropriate. It can control the filter pump when it requires to do so. 
 

AUTOMATIC MODE

.

 For fully automatic operation, simply plug it in and switch on. The unit will run the 

pump for 6 minutes (decimal point after the P flashing), then make a decision to heat the pool based on 
the sensor’s temperatures, activating the solar pump as required. When the pool has reached your preset 
"comfort" temperature, it turns everything off and waits 4 hours before starting the process again. 
 

Comfort Temperature Adjustment

 

Adjustment of the comfort level is achieved by pressing either the "+" or "-" buttons. The first operation 
will simply display the present comfort temperature. Any further operation of the buttons will increase or 
decrease the setting. The setting will automatically change if either button is pressed and held down.  
This temperature will be stored permanently in memory, even with power off. 
 

DISPLAY MODE.

 

To read roof, pool and comfort temperature settings, press the "DISPLAY" button. The 

display will cycle through the settings showing an "R" for roof , a "P" for pool or "L" for Last and a "C" for 
comfort.  
 

DISPLAY MEANING (Lower display)

 

P28 

L28

 

C30 

R48

 

Pool temp 

Last pool temp 

Shows  

Shows 

when filter pump is on. 

when filter pump is off. 

Comfort setting 30°C  

Roof temp 48°C 

Pool is 28°C 

Pool was 28 when  

 

pump was turned off. 

PPP

 

rrr

 

Flashing. 

Flashing. 

Faulty pool sensor, 

Faulty roof sensor, 

or pool temp outside 3° - 50° range 

or Roof temp outside 3° - 98° range 

 

NOTE: 

When  the  filter  pump  is  off,  controller  shows  the  L  temperature  as  the  pool  sensor  is  no  longer 

reading a valid temperature. 
 

WINTER MODE

 

The  MTFS  unit  is  equipped  with  a  unique  "Winter  mode"  facility  which  allows  the  user  to  exercise  the 
system  daily  throughout  the  colder  months.  By  using  this  facility  you  will  extend  the  life  of  your  solar 
heating by preventing pump seizure and drying of chemical build up in the collector.  

 
To select winter mode

, press the "WINTER" button. The display will show "W"

 

and the unit will turn on 

the solar pump for six minutes each time the filter pump comes on. For this function to work properly, at 
least one on and at least one off period needs to be programmed into the timer. 
To  resume  normal  operation,  press  the  "WINTER"  button  again  and  the  unit  will  begin  automatic 
operation. 