TROPICAL MODE

.

 This mode is used to cool your pool at night if it overheats in VERY hot weather, as 

well as heating during the day. Most people do not need to use this function. 
 

To  select  tropical  mode

,  the  unit  must  first  not  be  in  its  winter  mode  or  a  solar  override  mode.  Then 

press  the  "WINTER"  and  "DISPLAY"  buttons  together  for  5  seconds.  The  "TROPICAL"  LED  will  be  on, 
and the unit will then run the solar pump for 6 minutes, then make a decision on how to heat or cool the 
pool  based  on  the  sensor’s  temperatures,  activating  the  solar  pump  as  required.  When  the  pool  has 
reached  your  preset  "comfort"  temperature,  it  turns  everything  off  and  waits  4  hours  before  starting  the 
process  again.  Tropical  mode  will  be  remembered  after  a  power  interruption.  To  resume  normal 
operations, press the "WINTER" and "DISPLAY" buttons together.

 

 
 
OVERRIDE  MODES

.

 

Before  selecting  these  modes,  remember  that  the  unit  is  designed  to  work 

automatically. Overriding the automatic operation can result in overheating of your pool or spa or 
even cooling if the solar system continues to run when the sun is not shining. 
 
To  select  "timer  override  on",

  press  the  "TIMER"  button,  then  the  "+"  button.  The  top  display  will 

alternate  between  "On"  and  the  current  time,  and  the  filter  pump  will  go  on.  Automatic  solar  operations 
can  still  occur,  but  winter  mode  will  not  operate  (displays  "w"  instead  of  "W").  To  remove  the  override, 
press  the  "TIMER"  button,  then  the  "+"  button.  "Timer  override  on"  is  remembered  after  a  power 
interruption. 
 

To select "timer override off",

 press the "TIMER" button, then the "-" button. The display will alternate 

between  "OFF"  and  the  current  time,  and  the  filter  pump  will  go  off.  No  solar  operations  (automatic  or 
winter) are possible and "solar override on" mode (if selected) is ignored, and the display shows the last 
temperature  or  "w".  To  remove  the  override,  press  the  "TIMER"  button,  then  the  "-"  button.  "Timer 
override off" is remembered after a power interruption. 
 

To  select  "solar  override  on",

  press  the  "-"  and  "+"  buttons  together.  Pressed  for  a  short  period,  the 

solar (and filter) pump will normally go on for 1 hour. Holding them down for 5 seconds and 4 hours will be 
selected. The lower display will alternate between "On1" or "On4" and the pool (or last) temperature. To 
remove the override, press the "-" and "+" buttons together. "Solar override on" is NOT remembered after 
a power interruption. 

 
To  select  "solar  override  off"

,  press  the  "DISPLAY"  and  the  "+"  buttons  together  for  5  seconds.  The 

lower  display  will  show  "OFF".  The  solar  pump  will  be  off  and  no  solar  operations  (automatic  or  winter) 
are  possible.  Filter  pump  operations  can  still  be  controlled  by  the  timer  or  timer  override  modes.  To 
remove the override, press the "DISPLAY" and "+" buttons together. "Solar override off" is remembered 
after a power interruption 
 

 
ERROR INDICATIONS 

 
NOTE:  In  extremes  of  temperature,  the  sensor  fault  displays  may  show  although  the  unit  is  not  faulty. 
Remember the pool temperature is sensed from the inlet pipe which can  be much colder or hotter than 
the pool if the system has been off for some time. 
An  indicated  roof  or  pool  sensor  error  will  prevent  automatic  solar  operation  and  stop  solar  pump 
operation, but will allow winter mode (including solar pump operation). Roof and pool sensor errors may 
show in some override modes, and may or may not stop normal operations. 
 
If the unit displays "EEEE", then it has a memory fault, and may not operate correctly. The unit requires 
servicing

 

 
 

 

 
 
 
 
 
 

Solar Time Clock

 

Model MTFS 

 

The sun always shines with Ascon Pool 

 

r2 

 
 

 

 

 
 

 

Associated

 Controls (Australia) Pty Limited, 

ABN 210 002 245 64 

2–4 Norfolk Rd, Greenacre NSW 2190,Australia 

PO Box 5605, Chullora NSW 2190 

Tel: 61 2 9642 4922    Fax: 61 2 9642 4955 

Email:  

[email protected]

 Web: 

www.asconpool.com.au

 

22476-02.pdf 104942

 

Reviews: