INSTALLATION
IM14229-8
GB
4.
PNEUMATIC CONNECTION
The air flow is from port 1 to port 2.
Inch screw connections (pipe threads) must be used.
Each screw connections must be lined with a fitting synthetic sealing disc.
Do not use Teflon sealing tape or hemp as they may get inside the valve and damage it.
Use an appropriate silencer at port (3). The exhaust time may vary depending on the type of silencer used.
The diameter of the pneumatic lines must be adjusted to the nominal diameter of the valve. The diameter of outlet
line (2) must be larger or equal to that of inlet line (1).
The supply pressure must always be less than the value given in the table in section 3 and must always be above
the desired outlet pressure.
5.
TECHNICAL CHARACTERISTICS
CONSTRUCTION
INSTALLATION
Directly operated valve
Body: Aluminium
Internal parts: POM
Seals: Nitrile (NBR), fluorelastomer (FPM)
Degree of protection: IP65
Safety code:
q
II 2D Ex tb IIIC T135 °C Db
q
II 3G Ex nA IIC T4 Gc
0
≤
Ta
≤
+50 °C
EC type examination certificate no.: IBExU07ATEX1173
Assembly position: any; for optimum performance verti-
cally with solenoid at the top.
Air: filtered at 50
µ
m, free of condensatei
Connections: without hemp or Teflon sealing tape
Electrical connection: Select a wire section that will give a
a voltage drop of less than 2 volts at 2A.
5.1 FLUID CHARACTERISTICS
FLUIDS
: Air or neutral gas, filtered at 50
µ
m, free of condensate, lubricated or not
PORTS
: G1/8-G1/4-G1/2-G1
MAX. INLET PRESSURE
: see section 1.1
TEMPERATURE / FLUID
: 0...60 °C
TEMPERATURE / AMBIENT
: 0...50 °C
HYSTERESIS
: <1% of span
LINEARITY
: <0,5% of span
REPEATABILITY
: <0,5% of span
MINIMUM SETPOINT
: 50mV (0,1 mA/4,08mA) with shut-off function
MINIMUM OUTLET PRESSURE : 1% of span
Pressure supply
1
Exhaust
3
Pressure outlet
2