Asco Joucomatic 349 Series Manual Download Page 2

E S D

1. OUTPUT MODES

Hysteresis mode:

Adjustment of switch point 

H

 and hysteresis range 

h

.

Ex.:

H

 = 6 bar - 

h

 = 0.5 bar

N.O. (Normally Open)

4. CONFIGURATION OF N.O. / N.C. OUTPUTS AND

UNIT OF MEASURE

Factory setting:

6. LOCKOUT

Press the “mode” and “arrow down” keys simultaneously
to lock the pressure switch to prevent unwanted chan-
ges to the adjustments. Repeat the above procedure to
unlock the pressure switch and change the settings.

7. SETTING MODE

Initial settings: Output 1 & 2 = Normally Open

Unit of measure: bar

Desired setting for output 1 : Hysteresis mode;

switching at 6 bar;
hysteresis 0.5 bar.

■ 

Selection of mode for output 1:

9. ERROR MESSAGES

psi

kgf/cm²

MPa

bar

H - 1

71

5.00

0.49

4.9

h - 1

14

1.00

0.10

1.0

H - 2

99

7.00

0.68

6.8

h - 2

14

1.00

0.10

1.0

Window comparator mode:

Adjustment of lower limit 

and upper limit 

b

.

Ex.:

A

 = 4 bar - 

b

 = 6 bar

N.O. (Normally Open)

psi

kgf/cm²

MPa

bar

A - 1

42

3.00

0.29

2.9

b- 1

71

5.00

0.49

4.9

A - 2

85

6.00

0.59

5.9

b - 2

113

8.00

0.78

7.8

2. FRONT PANEL

Display :

Values previously set in setting mode
Pressure level in measurement mode

Mode :

Key to select the different modes

Up & Down :

Keys to change settings

Output LED :

Indication of output status
Output 1 ON = red, Output 2 ON = green.

3. ELECTRICAL CONNECTION

- Outputs: N.C. or N.O. at choice, max. 125 mA
- pin 1 = V+ = 

10.8 to 30 VDC

- pin 2 = output 2
- pin 3 = V--
- pin 4 = output 1

Type

Selected

unit of

measure

Display of
measured

pressure

To store the settings in the integrated EEPROM, press
the “mode” and the “arrow up” keys simultaneously.

Unit

Output 1

Output 2

PNP

bar

HYS, N.O.

HYS, N.O.

Select N.O. or N.C. for output 1

Select N.O. or N.C. for output 2

1x

bar

psi

kgf/cm²

MPa

Select desired unit of measure

1x

1x

Pressure

display

5. ZERO-POINT ADJUSTMENT

To reset to zero without connecting to pressure supply.

Hold for

min. 3 sec

Pressure

display

Pressure

display

Select hysteresis or

window comparator mode

(e.g. hysteresis)

Pressure

display

Pressure

display

1x

■ 

Setting of values for output 1:

Display

1x

Select switch point for output 1
with “up” or “down” arrow keys

1x

Select hysteresis for output 1

with “up” or “down” arrow keys

1x

Pressure

display

■ 

Selection of mode for output 2:

Display

4x

Select hysteresis or

window comparator mode

(e.g. window comparator)

1x

Pressure

display

■ 

Setting of values for output 2:

Display

3x

Select lower limit for output 2

with “up”  or “down”  arrow  keys

(e.g.: 4 bar)

1x

Select upper limit for output 2

with “up” or “down” arrow keys

(e.g.: 6 bar)

Pressure

display

1x

8. DISPLAY OF PEAK VALUE AND BOTTOM VALUE

The highest (max.) and lowest (min.) pressure values
measured from the time the outputs are connected to
power supply are stored in the integrated memory. The
values are displayed as follows:

Display

1x

Higest measured

pressure (e.g.: 7 bar)

Pressure

display

Display

1x

Lowest measured

pressure (e.g.: 2 bar)

Pressure

display

Pressure during zero-
point adjustment
exceeds ±3% F.S.

Overcurrent at output 1

Overcurrent at output 2

Applied pressure is
above calibrated
pressure range.

Readjust the zero
point in a different
pressure environment

Keep the current
below 125 mA at
maximum.
Check cabling.

Apply pressure
within the calibrated
pressure range.

Error

Message

Troubleshooting

Installation and operation

ELECTRONIC PRESSURE SWITCH WITH DIGITAL DISPLAY

Hysteresis and comparator functions

At 0 bar, the output signal is turned “OFF”. Whenever
pressure crosses above the switch point, the output si-
gnal is turned “ON”. As long as the pressure is above 5.5
bar (= 6 bar – 0,5 bar), the output signal remains “ON”.
Whenever pressure decreases and crosses below
5.5 bar, the output signal is turned “OFF”. In the N.C.
(Normally Closed) as opposed to the N.O. (Normally
Open) configuration, ON becomes OFF and vice-versa.
Factory setting: outputs 1 & 2 in the hysteresis mode.

At 0 bar, the output signal is turned “OFF”. Whenever
pressure crosses above the lower limit, the output signal
is turned “ON”. As long as the pressure level remains
within the upper and lower limits of the window, the out-
put signal remains “ON”. Whenever the pressure crosses
above the upper limit, the output signal is turned “OFF”.
In the N.C. (Normally Closed) as opposed to the N.O.
(Normally Open) configuration, ON becomes OFF and
vice-versa.
Factory setting:

PROGRAMMING PROCEDURE

0

H

h

OFF

ON

OFF

ON

0

OFF

ON

OFF

ON

Pressure

Output

LED 2

LED 1

Mode

+

--

CAUTION

OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES

0

OFF

ON

0

A

b

OFF

ON

OFF

ON

ON

OFF

ON

OFF

ON

OFF

ON

Pressure

Output

Display sequence when power is switched on.

Desired setting for output 2 : Window comparator mode;

switching in 4 to 6 bar range
(lower limit A = 4, upper limit b = 6)

2x

GB

Summary of Contents for Joucomatic 349 Series

Page 1: ...u comparateur à fenêtre Comparateur comme exemple 1x Affichage pression Réglage des valeurs sortie 2 Affichage 3x Sélection limite basse sortie 2 avec touche ou ex 4 bar 1x Sélection limite haute sortie 2 avec touche ou ex 6 bar Affichage pression 1x 8 AFFICHAGE DES VALEURS MAXI ET MINI La mémoire interne stocke la valeur la plus haute Maxi et la valeur la plus basse Mini mesurées à partir du mome...

Page 2: ... g window comparator 1x Pressure display Setting of values for output 2 Display 3x Select lower limit for output 2 with up or down arrow keys e g 4 bar 1x Select upper limit for output 2 with up or down arrow keys e g 6 bar Pressure display 1x 8 DISPLAY OF PEAK VALUE AND BOTTOM VALUE The highest max and lowest min pressure values measured from the time the outputs are connected to power supply are...

Page 3: ... den Modus Hysterese oder Fenster Komparator z B Fenster Komparator 1x Druck Anzeige Einstellung der Werte für Ausgang 2 Anzeige 3x Unteren Schaltpunkt für Ausgang 2 mit den Pfeiltasten OBEN UNTEN wählen z B 4 bar 1x Oberen Schaltpunkt für Ausgang 2 mit den Pfeiltasten OBEN UNTEN wählen z B 6 bar Druck Anzeige 1x 8 ANZEIGE DES HÖCHSTEN UND DES NIEDRIGSTEN WERTES Der höchste max und der niedrigste ...

Page 4: ... Taratura valori uscita 2 Visualizza 3x Seleziona limite inferiore uscita 2 con tasto o es 4 bar 1x Seleziona limite superiore uscita 2 con tasto o es 6 bar Visualizza pressione 1x 8 VISUALIZZAZIONE DEI VALORI MAX E MIN Vengono internamente memorizzati il valore più alto max e il valore più basso min misurati a partire dal momento in cui le uscite sono alimentate Possono essere visualizzati come s...

Page 5: ...Visualización 4x Selección modo histéresis o comparador en ventana Comparador como ejemplo 1x Visualización presión Regulación de los valores salida 2 Visualización 3x Selección límite bajo salida 2 con toque o ej 4 bar 1x Selección límite alto salida 2 con toque o ej 6 bar Visualización presión 1x 8 VISUALIZACIÓN DE LOS VALORES MÁX Y MÍN La memoria interna almacena el valor mas alto Máx y el valo...

Page 6: ...us hysteresis of meetklok met venster Meetklok als voorbeeld 1x Weergave druk Instelling van de waarden uitgang 2 Weergave 3x Selectie ondergrens uitgang 2 met toets of bijv 4 bar 1x Selectie bovengrens uitgang 2 met toets of bijv 6 bar Weergave druk 1x 8 WEERGAVEVANDEMAXIMUM ENMINIMUMWAARDEN Het interne geheugen slaat de maximale waarde Maxi en de minimale waarde Mini op die zijn gemeten vanaf he...

Reviews: