ASCENTO PRJ062 Instruction Manual Download Page 5

5 | 

P a g e      

A S C E N T O   G R O U P   A U S T R A L I A     P :   1 8 0 0 8 0 7 6 0 4       E :   s a l e s @ a s c e n t o . c o m . a u

 

 

ASCENTO GROUP AUSTRALIA 

P: 1800 807 604  

F: 1800 807 609 

E: [email protected] 

 

INSTRUCTION MANUAL & WARRANTY EXTERNAL CONSTANT PRESSURE PUMPS 

 
 

APPLICATION: CONSTANT PRESSURE PUMPS are fit for purpose when installed correctly according to these instructions;   
For pumping of Clean Fresh Water at a temperature of +5°C to +40°C to: Garden Taps, Houses, Sheds, Cabins, Pressure Boosting, 
Clean Water Transfer, suitable Rain-to-Mains Systems (370Watt and greater motor size) and for no other use.  They must not be 
used in hazardous locations or for liquids other than clean water, or for continuous operation.  

 

DANGER:  

DO NOT INSTALL ANY PUMP if the premises does not have a Safety Switch (RCD)

 

 
IMPORTANT: 

Ensure  the  pump  is  the  right  size  for  your  application,  before  you  install  it.    A  pump  that  is  under-sized  is  not 

faulty, and is not covered by warranty. Ensure the right size piping is used, small pipes reduce performance and cause the pump 
to use more power! See below for further information, and refer to the information on the box and/or label on the pump for the 
performance data. If in doubt consult with your dealer or a pump technician to ensure your pump is sized to suit your needs.    

 

PERFORMANCE DATA 

Refer to the information on the box.

 

NOTES:  Performance data quoted is generally from test data, and can vary, and does not take into account factors in the installation 
such  as  loss  of  pressure  and  flow  due  to  pipework  &  pipe-fittings  &  valves.    Product  depicted  on  the  box  and  referred  to  in  this 
document,  and  other  diagrammatic  instructions,  may  differ  from  the  product  supplied,  due  to  design  changes  or  improvements. 
***Be aware that the Amps and Wattage will vary according to the load on the motor, the figures stated are approximate. 

 

INSTALLATION GUIDELINES 

Please  read  and  follow  the  instructions  including  the  diagrammatic  instructions.    Warranty  is  voided  if  the  instructions  are  not 
followed.  

 
1a.

  

IMPORTANT MANDATORY REQUIREMENTS FOR ALL INSTALLATIONS:

  

Before installing or servicing disconnect from the power 

supply. All pumps must be installed using barrel-union connections to facilitate easy servicing or replacement.  Ball-valves or gate-
valves must be fitted on the suction, and the discharge, and the Town-water backup supply where fitted. A Y-Strainer or Pre-filter 
must be installed on the suction to prevent particles entering the pump. Remove all swarf from the tank after cutting openings etc 

 

swarf in the pump voids warranty. All instructions are conditions of warranty; all warranty is void if instructions are not followed.   
It  is  recommended  to  install  a  Check-Valve  in  the  discharge  pipework,  however  DO  NOT  install  the  check  valve  directly  on  the 
discharge of the Pressure Controller, as this may cause it to malfunction, install the Check-Valve further down the pipe, before the 
first point of discharge.   
 

1b.

 

IRRIGATION  USE  -  MANDATORY  REQUIREMENTS  FOR  ALL  INSTALLATIONS:

   

For  any  installation  of  these  pumps  that  is 

supplying irrigation, you must fit an 18L or larger pressure tank.  Air pressure must be set at 70% of maximum pump pressure.  Tank 

is simply fitted to the discharge pipework with a “tee”, anywhere between the pump and the first point of discharge.

 

 
2.POSITION

 Do not position the pump where it could take in solids or sludge. This pump is not to be used as your sole water supply. 

For  critical  applications  where  loss  of  water  supply  could  cause  serious  consequences,  use  a  DUAL  PUMP  System  so  you  have  a 
second water supply or use a TOWN-WATER BACK-UP SYSTEM. This pump is not designed for Fire Fighting purposes. 

 
3.PROTECT FROM THE WEATHER:

  The pump must be protected from the weather, by way of a plastic pump cover or skillion roof 

cover, or similar. However the installer must ensure that there is adequate ventilation so the pump does not overheat. 

 
4.  IMPORTANT  re  INSTALLATION:

  This  pump  MUST  NOT  be  installed  in  any  manner  that  if  it  were  to  leak  that  it  would  cause 

damage  or  loss  to  property  or  persons.  It  MUST  be  installed  in  a  well-ventilated  and  drained  area.  All  warranty  is  void  if  this 
condition  is  not  heeded  and  no  liability  can  be  accepted  in  the  case  of  damage  or  loss  caused  by  failing  to  comply  with  this 
condition.  If the pump leaks, the water must be able to drain away from the pump and not cause damage.   
 

DANGER!!!!

 

If water pools around the pump (from any source of water) it will cause a dangerous electrical hazard. 

 
5.BASE must be LEVEL

  Fix the pump in place through the footplate using suitable fasteners, on a stable, level surface 

 the base 

must NOT be sloping even slightly 

 ensure it is level. 

 
 
 

Summary of Contents for PRJ062

Page 1: ...1 P a g e A S C E N T O G R O U P A U S T R A L I A P 1 8 0 0 8 0 7 6 0 4 E s a l e s a s c e n t o c o m a u ...

Page 2: ...2 P a g e A S C E N T O G R O U P A U S T R A L I A P 1 8 0 0 8 0 7 6 0 4 E s a l e s a s c e n t o c o m a u ...

Page 3: ...3 P a g e A S C E N T O G R O U P A U S T R A L I A P 1 8 0 0 8 0 7 6 0 4 E s a l e s a s c e n t o c o m a u ...

Page 4: ...4 P a g e A S C E N T O G R O U P A U S T R A L I A P 1 8 0 0 8 0 7 6 0 4 E s a l e s a s c e n t o c o m a u ...

Page 5: ...cement Ball valves or gate valves must be fitted on the suction and the discharge and the Town water backup supply where fitted A Y Strainer or Pre filter must be installed on the suction to prevent particles entering the pump Remove all swarf from the tank after cutting openings etc swarf in the pump voids warranty All instructions are conditions of warranty all warranty is void if instructions a...

Page 6: ...ions it is the installers responsibility to ensure compliance 10 IMPORTANT re SAFETY SWITCH RCD a The Pump must be connected to a suitable power circuit protected by a RCD safety switch having a rated residual operating current not exceeding 30mA in the circuit breaker 3 Phase 415 Volt Pumps must be installed by a licenced Electrician according to applicable Regulations Australian Standards Discon...

Page 7: ...in to reset it If this problem reoccurs check as per 15 18 IMPORTANT NOTES a Do not switch the pump on and off frequently as this will cause damage to the electronics and void warranty b Do not attempt to adjust the flow via the intake pipework c If there is insufficient water the motor will stop See 15 f and also 19 d If the pump is idle for a long period of time or in very low temperature the wa...

Page 8: ... be closed open the valve 3 Impeller or volute openings are fully or partially clogged or it might be blocked with debris or the Y Strainer Prefilter might be blocked flush clean and re assemble if it is the pump disconnect from the power supply and if you are competent to do so disassemble the pump and clean If not have a pump technician do it for you 4 Pump is air locked Start and stop several t...

Page 9: ...___________________________________________________________________________ Tick the boxes as the item is completed correct put n a if not applicable The Pump is being used for an appropriate purpose for which it is intended according to the instructions The Power Circuit the Pump is connected to is RCD Safety Switch Protected A Y Strainer or Pre filter is installed in the suction pipe to prevent ...

Page 10: ...f the rainwater tank is installed under eaves or other structure such as a deck ensure that the pump can be easily removed for servicing or repairs Warranty replacement does not normally include costs of removal and re installation as we have no control over the method of installation 8 Before installing or servicing disconnect from the power supply A ball valve or gate valve must be fitted on the...

Reviews: