![Ascent Communication Technology AT5000 OPSW Quick Reference Manual Download Page 9](http://html1.mh-extra.com/html/ascent-communication-technology/at5000-opsw/at5000-opsw_quick-reference-manual_2980887009.webp)
AT5000 1RU Optical Switch with RF
Solutions Provider for FTTx, RFoG and HFC www.ascentcomtec.com
Page 9 of 21
Press ↑ ↓and ENT button, you can see the following information
AT-50-OPSW
Outpwr L/H
Working Channel
Channel A/B
CH A Input Power
L-60.0dBm
CH B Input Power
L-60.0dBm
Switch Mode
Auto
Switch to
Disable
Detection of RF A/B
Alarm!
Temperature
34.3
°C
Switch
Mode Auto
Switch
Mode
Manual
Switch to
CH A
Switch to
CH B
L: output power
≤
5dBm
H: output power
≥
5dBm
-60.0dBm: No output power
1.
In auto mode and RF detect function
turns off, when the input power of
channel A is lower than preset value, it
will switch to channel B automatically.
2.
In auto mode and RF detect function
turns on, only the input power of both
channels is higher than +0dBm, the
switch function can work normally.
3.
In manual mode, users can switch
freely between A and B channel.
Only in Manual working mode this menu is
available otherwise Disable displayed. Press
ENT to switch A to B, A means switch to A,
currently working in channel B.
RF detector alarm menu. Only turn on the
Detection of RF in setting menu, it is
available, otherwise disable displayed.
Factory setting is OFF.
ENT
ENT