AT5200 FTTX Multiport EDFA
Solutions Provider for FTTx, RFoG, and HFC
www.ascentcomtec.com
Page 22 of 24
OEM Settings Page
Any time the fiber leads to the amplifier are disconnected, there is the potential for
contamination of the ends of the fiber connectors. Dirt or other contaminants on these
components can reduce the amplifier’s performance and can result in permanent damage to
the device. It is recommended that the fiber connectors be cleaned prior to connection, or
reconnection, to the system.
S/N
Fault Phenomenon
Faulty Reason
Solution
Remarks
1
Power Yellow
Single power supply working
Connect another power
supply
2
STATUS Green
INPUT Yellow
OUTPUT Green
Single optical input
Connect another input
Dual Model
3
STATUS Red
INPUT Yellow
OUTPUT Red
No input or input too low
Adjust the value of
input power
4
STATUS Red
INPUT Green
The key turned to OFF
Turn the key to ON