P1/P2/P3/P4 

– COFFEE PREINFUSION

We can program the “on” time of the preinfusion. The pump “off” time is always three 
seconds. Maximum seconds are 5 seconds.

Example:

P1: Preinfusion 

S

 key 1 press (short coffee single)

P2: Preinfusion 

S

 key 2 keystrokes (short coffee double)

P3: Preinfusion 

L

 key 1 press (long coffee single)

P4: Preinfusion 

L

 key 2 keystrokes (long coffee double)

Cr 

– CHRONOMETER FUNCTION

We can activate or deactivate the display of coffee delivery time.

– OFFSET TEMPERATURE

This parameter is used to correct the temperature difference between the display group 
data and the actual temperature value at the output group.

AC 

- To activate and deactivate the steam boiler

EP

- It allows configuring the hydraulic connection as NETWORK or TANK.

SP

 – Indicates the number of total services of the machine since the last reset to 0.

ST

 – Indicates the number of total services of the machine.

ESC

 – To exit of the menú.