ACR1281U-C1 – Application Programming Interface
Version 1.08
www.acs.com.hk
Page 26 of 96
5.1.5.
Memory Card – SLE4418/SLE4428/SLE5518/SLE5528
5.1.5.1.
Select card type
This command powers down/up the selected card in the reader, and then performs a card reset after.
Command
Command
Class
INS
P1
P2
Lc
Card Type
Select Card Type
FFh
A4h
00h
00h
01h
05h
Response
Response
Data Out
Result
SW1
SW2
Where:
SW1 SW2
= 90 00h if the operation is completed successfully.
5.1.5.2.
Read memory card
This command reads the memory card’s content from a specified address.
Command
Command
Class
INS
Byte Address
MEM_L
MSB
LSB
Read Memory Card
FFh
B0h
Where:
MSB Byte Address
(1 byte)
= 0000 00 A9 A8b is the memory address location of the memory
card
LSB Byte Address
(1 byte)
= A7 A6 A5 A4 A3 A2 A1 A0b is the memory address location of the
memory card
MEM_L
(1 byte)
Length of data to be read from the memory card
Response
Response
Byte 1
…
…
Byte N
SW1
SW2
Result
Where:
Byte (1…N)
Data read from memory card.
SW1 SW2
= 90 00h if the operation is completed successfully.