background image

 

 

2   

asberprofessional.com

 

 

 

     

 

 

 

 

 

 

 

 

      

asberprofessional.com

 

INSTALLATION 

2.1 General information 
2.2 Transport, handling, unpacking, location. 
2.3 Intended use and restrictions. 
2.4 

Manufacturer’s identification label description. 

2.5 Installation and assembly. 
2.6 Connections (electric, gas, water) 

 

2.1 

General information 

You  can  find  in  you  equipment  the  following  symbols,  or  stickers  to  identify  some  type  of  warnings  or 
useful information about  your equipment. 

 

 

 

 

2.2 

Transport, handling, unpacking, location 

Upon receiving your new ASBER Display Case, check the package and the machine for any damages 
that may have occurred during transportation. Visually inspect the exterior of the package, if damaged, 
open  and  inspect  the  contents  with  the  carrier.  Any  damage  should  be  noted  and  reported  on  the 
delivering carrier’s receipt. 
 
In  the  event  that  the  exterior  is  not  damaged,  yet  upon  opening,  there  is  concealed  damage  to  the 
equipment notify the carrier immediately. Notification should be made verbally as well as in written form. 
Request an inspection by the shipping company of the damaged equipment. 
Retain  all  crating  material  until  inspection  has  been  made.  Contact  the  dealer  through  which  you 
purchased the unit.  
 
Check the compressor compartment housing and visually inspect the refrigeration package. Be sure  
lines are secure and base is still intact. 
 
 
 

Summary of Contents for ACTC-55

Page 1: ...ions Installation and Operation Manuel talimatları Kurulum ve Çalıştırma Manual de instrucciones Uso y mantenimiento Manuel d instructions Installation et fonctionnement Bedienungshinweise Installation und Betrieb Manual do instruções Instalação e Operação Ręczny Obsługa i konserwacja ES EN D T F P P AS OF NOVEMBER 1 2015 ...

Page 2: ...tions 3 2 4 Manufacturer s identification label description 3 2 5 Installation and assembly 4 2 6 Connections 4 OPERATION 4 3 1 General information 4 3 2 Control panel description 4 3 2 1 Electronic Control 4 3 3 Machine settings and programs 5 MAINTENANCE 6 4 1 General safety rules 6 4 2 Machine cleaning and maintenance routine 6 4 2 1 Cleaning the Condenser Coil 6 4 2 2 Draining the Unit 7 4 3 M...

Page 3: ...ompressor mount on right side Cold plate design underneath the pans to keep products fresher and maintain products at 36 46 F temperature in food pans 1 2 Important safety information DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit If machine still running when power is off disconnect power at the circuit...

Page 4: ...or any damages that may have occurred during transportation Visually inspect the exterior of the package if damaged open and inspect the contents with the carrier Any damage should be noted and reported on the delivering carrier s receipt In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier immediately Notification should be m...

Page 5: ...ms to UL and NSF 7 standards If you want know more about other restrictions about your equipment see the warranty that is located in the final part of your manual 2 4 Manufacturer s identification label description The data plate is located inside the cabinet near the top front left corner Under no circumstances should the data plate be removed from the unit The data plate is essential to identify...

Page 6: ...his manual or on data plate and your local code or the National Electrical Code to be sure unit is connected to the proper power source Verify correct incoming voltage according to the Data Plate information The data plate in located inside the unit near the top front left corner Under any circumstances should the data plate be removed from the unit The data plate is essential to identify the part...

Page 7: ...f the set point for a new temperature press the button DOWN arrow see the picture below Press this button to reach the desired value Release the button and then press the SET button to keep and save the new value Note The minimum value you can set in the controller is For refrigerators 1 C 30 F Manual Defrost To select manual defrost hold the button DOWN arrow for 5 seconds The snow flake icon wil...

Page 8: ... tomatoes and other vegetables 4 2 1 Cleaning the Condenser Coil Disconnect machine Remove front bottom panel and carefully slide out the condensing unit The condenser coil requires regular cleaning recommended every 30 60 days depending of the accumulation of dust and grease If the buildup on the coil consists of only light dust and debris the condenser coil can be cleaned with a simple brush Hea...

Page 9: ...EMBER TO TAKE CARE OF THE ENVIRONMENT TROUBLESHOOTING CHART 5 1 Troubleshooting guide chart 5 1 Troubleshooting Follow the next steps before requesting warranty service Failure to do so may result in service charges for you and may void your warranty 1 Refrigerator doesn t work a Check that the machine is still connected b Check that the ON OFF button is in the ON position 2 Refrigerator doesn t r...

Page 10: ...ed warranty only applies to sealed parts of the compressor and does not apply to any other part or component including but not limited to cabinet temperature control refrigerant motor starting equipment fan assembly or any other electrical or mechanical component Exclusions from and Conditions to Warranty Coverage This Warranty does not cover parts or accessories which a carry the warranty of a su...

Page 11: ...yment of or crediting the user with an amount equal to the purchase price of such goods Prices Specifications Asber reserves the right to change the prices and specifications of the equipment and or material without notice Prices are FOB Asber warehouses All orders are subject to acceptance by Asber Commercial Inc Terms All orders are subject to credit approval All Invoices not paid within the spe...