Page C-3
Maximum Cable Lengths
❏
10Base5 (thick Ethernet, AUI): 50 meters maximum to
Ethernet MAU (transceiver) with shielded, twisted-pair
drop cable.
❏
10Base2 (thin Ethernet, BNC): 185 meters maximum per
segment
❏
10BaseT (twisted-pair, UTP): 100 meters maximum,
24 AWG UTP
Physical Dimensions
❏
All hubs are 8.6 inches x 5.3 inches x 1.35 inches
(LxWxH)
Environment
❏
Temperature:
Operating 0 degrees C to +50 degrees C
Storage –20 degrees C to +70 degrees C
❏
Humidity:
Operating 10% to 80% RH
Storage 5% to 90% RH
Power Requirements
❏
Input voltage to wall-mount power adapter: voltage
matched to the voltage of the country in which the unit
is being used, 30 watts minimum
❏
Frequency: 47 Hz to 63 Hz
❏
Output Voltage: 12 Volt AC @ 1.25 Ampere, 15 VA maxi-
mum
Power Supplied by AUI Port
❏
+13 Volt DC, 500 mA maximum