AsahiAV Y-SEDIMENT STRAINER User Manual Download Page 3

3

 2.

 1.

1. Loosen the union nut and remove the union nut and the end connector.

2. Lead the union nut through the pipe.

3. The end connector is joined according to each joining method.

 3.

Body

End Connector

Union Nut

Union Nut

Union Nut

Pipe

Socket End

-When using an adhesive, ventilate the space sufficiently, prohibit the use of a fire in the vicinity, and do not inhale 

 adhesive vapors directly.

-Take care in doing work at low temperatures.  Solvent vapors are hard to evaporate and are likely to remain. (Solvent

 cracks may occur, damaging the equipment.)  After assembling the piping system, open both ends of the piping and

 use a fan (of the Low-Voltage Type) or something similar to ventilate the space, thus removing the solvent vapors.

-Do not apply more cement than necessary.  Avoid getting cement in the internals of the valve. This can cause damage 

 to the seals and moving parts. Solvent and fumes can chemically attack the valve materials if allowed to enter the 

 internals of the valve. (Cementing with the valve in a vertical position should be avoided)

-Do not under any circumstances try to insert a pipe into another fitting or valve by striking it, which may break the 

 piping.
-Use Asahi AV cement Number-32, Number-52, or Number-62 for PVC in case of JIS Pipe & Fittings.  The other 

 standard Pipe & Fittings shall be used industrial proper PVC cement.

-Allow 24 hours for solvent cement to dry before performing a water leak test.

 

 

 

-If an adhesive gets into contact with your skin, wash it off immediately. If you feel sick or find any anomaly, receive a 

 physician's diagnosis and take appropriate measures promptly.

 

4. Entry of the Bench Mark: The bench mark indicates the maximum penetration 

 depth of the pipe into the end connector.

5. Cleaning: Clean the hub part of the end connector by wiping with a waste cloth.

6. Application of adhesive: Apply adhesive evenly to the hub part of the end 

 connector and the pipe spigot.

7. Insertion: After applying adhesive, insert the pipe quickly into the end connector 

 and leave it alone for at least 60 seconds. 

8. Insertion completion: Wipe away overflowing adhesive.

9. Advance to step #10.

Cement

Sealing Tape

-Make sure that the threaded connections are plastic x plastic. 

 (

Metallic thread can cause damage.

-Wrap the threaded joints on our plastic piping with sealing tape. 

 Using a liquid sealing agent or liquid gasket may cause stress cracks 

 (Environmental Stress Cracking).  Our product warranty shall not apply

 in case of said use, even when said use is unavoidable.

-Avoid excessive tightening. (The valve can be damaged.)

 

1. Loosen the union nut and remove the union nut and the end connector.

2. Preparation: The seal tape is wound to the Male threaded adapter. (2 to 3 

 complete wraps around the male threads are sufficient.)

3. Connection: Tighten the external thread of the joint and the end connector hand 

 tight. Using the spanner wrench, screw in the end connector by turning 180°-360°

 carefully without damaging it.

4. Advance to step #10. 

 

Warning

 

Caution

 

Caution

Threaded End

User's Guide

For the Owner and the Installing Contractor

Serial No. :UA

006E

Y-SEDIMENT STRAINER

 10.

 11. 12.

O-Ring(A)

Threaded End

Socket End

10. Make sure that O-ring(A) is mounted.

11. Tighten union nut by hand.

12. Using a strap wrench tighten union nuts 

 uniformly on each side approx 90

  

-180

 

, 1/4 

 to 1/2 turns. (Do not use pipe wrench.)

Reviews: