[AKD55X4-B]
<KM119202>
2015/09
2. [Data Read/Write]:
Dialog box to manually enter register setting
Click the [Data R/W] button in the main window to open the data read/write dialog box.
Data manually entered into Data box is written to the specified address.
Figure 7-5. Window of [Data R/W]
Textbox Functions:
[Address]
: Input register address in 2 hexadecimal digits.
[Data]
: Input register data in 2 hexadecimal digits.
[Mask]
: Input mask data in 2 hexadecimal digits. This value is AND-ed with input data.
Button Functions:
[Write]
: Writes data generated from [Data] and [Mask] to register specified in [Address]
[Read]
: Displays register data specified in [Address] in [Read Data] box in hexadedimal.
[Close]
: Closes dialog box. To cancel a process close the dialog box without writing
※
Register map updated after [Write] and [Read] operation.
- 27-